Anika M. McManamen

Anika M. McManamen

Auto-generated profile, based on publicly available information

Anika M. McManamen

Department of Chemistry, University of Washington, Box 351700, Seattle, Washington 98195, United States

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 August 2022 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ULUlri N. Lee
Ulri N. Lee
XSXiaojing Su
Xiaojing Su
DHDamielle L. Hieber
Damielle L. Hieber
WTWan-Chen Tu
Wan-Chen Tu
AMAnika M. McManamen
Anika M. McManamen
STSanitta Thongpang
Sanitta Thongpang
This paper presents a new sample collection platform for a common bacterial infection, group A streptococcal (GAS) pharyngitis, also known as strep throat, caused by Streptococcus pyogenes.

17 December 2023 in medRxiv
Verified
Preprint
Open access
PDF file
WTWan-Chen Tu
Wan-Chen Tu
IJIngrid Jeacopello
Ingrid Jeacopello
ABAndrea Blom
Andrea Blom
EAElena Alfaro
Elena Alfaro
VSVictoria A. M. Shinkawa
Victoria A. M. Shinkawa
ATAshleigh B. Theberge
Ashleigh B. Theberge
Objective Determine the feasibility of using CandyCollect, a lollipop-inspired open-microfluidic pathogen collection device, to capture Group A Streptococcus (GAS) and compare user preference for CandyCollect, conventional pharyngeal swabs, or mouth swabs in children with pharyngitis and their caregivers. Methods Children (aged 5-17 years) with pharyngitis who tested positive for GAS via rapid antigen detection test from a pharyngeal swab were included in the study at an ambulatory care clinic in Madison, WI. Caregiver-child dyads were enrolled in the study so that both could provide user feedback regarding the experience. Immediately after the clinical visit, children were asked to suck on two mouth swabs and two CandyCollect devices. GAS presence was confirmed and measured with qPCR. Results All child participants (30/30) were positive for GAS by qPCR on both the mouth swab and CandyCollect. Caregivers ranked CandyCollect as a good sampling method overall (27/30), and all caregivers (30/30) would recommend the CandyCollect for children 5 years and older. Twenty-three of 30 children ″really like″ the taste and 24/30 would like to use the CandyCollect if another test was needed. All caregivers (30/30) and most children (28/30) would be willing to use the CandyCollect device at home. Conclusion All participants (30/30) tested positive for GAS on all three collection methods (pharyngeal swab, mouth swab, and CandyCollect). While both caregivers and children like the CandyCollect device, some caregivers would prefer a shorter collection time. Future work includes extending the capabilities of CandyCollect to additional pathogens and shortening collection time while maintaining the attractive form of the device.

27 February 2025 in Bioengineering & Translational Medicine
Verified
Journal Article
Open access
WTWan‐Chen Tu
Wan‐Chen Tu
IRIngrid H. Robertson
Ingrid H. Robertson
ABAndrea Blom
Andrea Blom
EAElena Alfaro
Elena Alfaro
VSVictoria A. M. Shinkawa
Victoria A. M. Shinkawa
ATAshleigh B. Theberge
Ashleigh B. Theberge
State the Purpose: Obtaining high‐quality samples to diagnose streptococcal pharyngitis in pediatric patients is challenging due to discomfort associated with traditional pharyngeal swabs. This may cause reluctance to go to the clinic, inaccurate diagnosis, or inappropriate treatment for children with sore throats. Here, we determined the efficacy of CandyCollect, a lollipop‐inspired open‐microfluidic pathogen collection device, to capture Group A Streptococcus (GAS) and compare user preference for CandyCollect, conventional pharyngeal swabs, or mouth swabs in children with pharyngitis and their caregivers.Results: All child participants (30/30) were positive for GAS by qPCR on both the mouth swab and CandyCollect. Caregivers ranked CandyCollect as a good sampling method overall (27/30), and all caregivers (30/30) would recommend CandyCollect for children 5 years and older. Twenty‐three of 30 children “really like” the taste and 24/30 would prefer to use CandyCollect if a future test were needed. All caregivers (30/30) and most children (28/30) would be willing to use CandyCollect at home.Conclusion: All participants tested positive for GAS on all three collection methods (pharyngeal swab, mouth swab, and CandyCollect). While both caregivers and children like CandyCollect, some caregivers would prefer a shorter collection time. Future work includes additional studies with larger cohorts presenting with pharyngitis of unknown etiology and shortening collection time while maintaining the attractive form of the device.

14 January 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
WTWan-Chen Tu
Wan-Chen Tu
AMAnika M. McManamen
Anika M. McManamen
XSXiaojing Su
Xiaojing Su
IJIngrid Jeacopello
Ingrid Jeacopello
MTMeg G. Takezawa
Meg G. Takezawa
ATAshleigh B. Theberge
Ashleigh B. Theberge
Respiratory infections are common in children, and there is a need for user-friendly collection methods. Here, we performed the first human subjects study using the CandyCollect device, a lollipop inspired saliva collection device. 1 We showed the CandyCollect device can be used to collect salivary bacteria from healthy adults using Streptococcus mutans and Staphylococcus aureus as proof-of-concept commensal bacteria. We enrolled healthy adults in a nationwide (USA) remote study in which participants were sent study packages containing CandyCollect devices and traditional commercially available oral swabs and spit tubes. Participants sampled themselves at home, completed usability and user preference surveys, and mailed the samples back to our laboratory for analysis by qPCR. Our results showed that for participants in which a given bacterium ( S. mutans or S. aureus ) was detected in one or both of the commercially available methods (oral swab and/or spit tubes), CandyCollect devices had a 100% concordance with the positive result (n=14 participants). Furthermore, the CandyCollect device was ranked the highest preference sampling method among the three sampling methods by 26 participants surveyed (combining survey results across two enrollment groups). We also showed that the CandyCollect device has a shelf life of up to 1 year at room temperature, a storage period that is convenient for clinics or patients to keep the CandyCollect device and use it any time. Taken together, we have demonstrated that the CandyCollect is a user-friendly saliva collection tool that has the potential to be incorporated into diagnostic assays in clinic visits and telemedicine. For Table of Contents Only:

27 February 2025 in bioRxiv
Verified
Preprint
Open access
PDF file
JBJean Berthier
Jean Berthier
JTJodie C. Tokihiro
Jodie C. Tokihiro
AMAnika M McManamen
Anika M McManamen
TCTj Caira
Tj Caira
ASAlbert Shin
Albert Shin
EBErwin Berthier
Erwin Berthier
The Lucas-Washburn-Rideal law is commonly applied to describe capillary flow dynamics in closed or open channels, microporous media, such as paper pads and fiber threads or even granulous soil. It assumes a viscous flow regime where capillary forces are counteracted by friction with the solid structure, a valid assumption given the small flow velocities and device dimensions. However, scenarios exist outside the viscous regime, where inertial effects become significant, meaning capillary and friction forces do not fully balance. One well-documented case is the transient inertial regime at the onset of capillary motion. With the advancement of capillary devices, other configurations also raise the possibility of inertia influencing flow behavior. This study introduces a criterion to identify inertial contributions in capillary-driven flows in spatially varying geometries within open or closed channels and demonstrates how the Bosanquet equation can account for inertial effects in rectangular open-channel configurations.

27 April 2023 in bioRxiv
Verified
Preprint
Open access
PDF file
JTJodie C. Tokihiro
Jodie C. Tokihiro
AMAnika M. McManamen
Anika M. McManamen
DPDavid N. Phan
David N. Phan
STSanitta Thongpang
Sanitta Thongpang
TBTerence D. Blake
Terence D. Blake
JBJean Berthier
Jean Berthier
The true value of the contact angle between a liquid and a solid is a thorny problem in capillary microfluidics. The Lucas-Washburn-Rideal (LWR) law assumes a constant contact angle during fluid penetration. However, recent experimental studies have shown lower liquid velocities than predicted by the LWR equation, which are attributed to a velocity-dependent dynamic contact angle that is larger than its static value. Inspection of fluid penetration in closed channels has confirmed that a dynamic angle is needed in the LWR equation. In this work, the dynamic contact angle in an open channel configuration is investigated using experimental data obtained with a range of liquids, aqueous and organic, and a PMMA substrate. We demonstrate that a dynamic contact angle must be used to explain the early stages of fluid penetration, i.e., at the start of the viscous regime, when flow velocities are sufficiently high. Moreover, the open channel configuration, with its free surface, enhances the effect of the dynamic contact angle, making its inclusion even more important. We found that for the liquids in our study, the molecular-kinetic theory (MKT) is the most accurate in predicting the effect of the dynamic contact angle on liquid penetration in open channels.