19 December 2022 in IEEE Systems Journal
Conventional protection schemes are vulnerable to varying changes in a microgrid with different types of distributed generators (DGs), which alter the fault current levels, leading to miscoordination of directional over-current relays (DOCRs). Due to limited storage in numeric relays, having one setting for each network scenario in the relays is infeasible. Also, schemes with one setting considering grid-connected mode (GCM) and islanded mode (IM) of operation with multiple scenarios may be infeasible for a microgrid with inverter-interfaced DGs due to low short-circuit level in IM. Thus, this article proposes an adaptive trip characteristics-based relay coordination scheme for a microgrid with different DGs, where two trip characteristics are assigned to each DOCR, one each for GCM and IM. Also, a novel framework for selecting the suitable trip characteristic is proposed. Hardware-in-loop simulations using Numerical Relay Development Environment for a meshed CIGRE microgrid, modified IEEE 34-bus distribution system, and comparison with previous works validate the proposed method's performance for various scenarios, such as the outage of a DG or line, variations in solar irradiation and wind speed, and network reconfiguration for different fault types during GCM and IM.
11 January 2019 in IEEE Transactions on Power Delivery
8 June 2022 in IEEE Transactions on Smart Grid
Continuous injection-based islanding detection of Inverter-Interfaced Distributed Generator (IIDG) has been a general trend. The major issues in previous islanding detection methods are large Non-Detection Zone (NDZ), poor Power Quality (PQ), high implementation cost, and lack of real-time validation. Further, the threshold in most methods is not generic and depends on the system’s rating. Hence, this paper proposes a local voltage and current measurement-based islanding detection method for IIDGs. It utilizes parameters estimated from the fundamental phasors of voltage and current at the Point of Common Coupling (PCC) of IIDG using Space Vector Rotation (SVR) and a controlled self-decaying current injection. The proposed disturbance is injected only after disturbance detection by SVR parameters to mitigate the impact on PQ. Disturbance identification is easy due to the combined PCC voltage and current effects on parameter estimation. Real-Time Digital Simulator (RTDS) and Controller Hardware In the Loop (CHIL) setup-based results from the proposed method have been obtained and compared with previous methods. These results indicate the proposed method’s real-time efficacy (low islanding detection time) with no NDZ and negligible impact on PQ for different islanding events. Also, the proposed method is independent of the microgrid’s rating and reliable for non-islanding events.
5 August 2021 in IEEE Transactions on Instrumentation and Measurement
Maintaining the power quality (PQ) of supply in a microgrid is a challenge due to the massive integration of inverter interfaced distributed generators (IIDGs). Supply's PQ and IIDG controller's transient performance degrade due to continuous, uncontrolled, and nondecaying injections in active methods for islanding detection. Also, active methods have limited application due to increased total harmonic distortion (THD) of current during microgrid's operation. In this article, a novel sequence measurement-based identification of grid disturbance by sensing voltage and current is proposed to control the disturbance injection cycle in the IIDG controller during islanding detection. The disturbance is a low-frequency decaying current injection in the IIDG controller with controlled input. The proposed method is experimentally verified in controller hardware in loop (CHIL) with real-time digital simulator (RTDS) using the TMSF28335 microcontroller and compared with several previous methods. The impact on PQ due to change in the injection points with controlled and uncontrolled injections is also analyzed. The results indicate that the islanding detection time is low. Also, the proposed closed-loop method is effective and reliable due to two-stage screening. The nondetection zone (NDZ) is eliminated with negligible impact on the PQ of supply.
6 February 2024 in IEEE Transactions on Power Systems
As Inverter-Based Resources (IBRs) gradually replace conventional synchronous generators (SGs), Dynamic State Estimation (DSE) techniques must be extended for the monitoring of IBRs. The key difference between IBRs and SGs is that the dynamics of IBRs comprise a heavy mix of physical processes and digital controller computations. This paper develops a generic framework of Control-Physics Dynamic State Estimation (CPDSE) for IBRs. First, a control-physics state-space representation of IBRs is presented. Noting the symmetry of the control and physical state spaces, it is proposed to use two dual estimators to track the states of the physical inverter subsystem and the digital controller subsystem, respectively. The CPDSE framework has the capability of suppressing errors in both measurement signals and control signals flowing between the two subsystems and the potential to distinguish between cyber and physical events. The advantages and versatility of the proposed CPDSE framework are validated on a variety of IBR systems (solar, wind, and storage), control strategies (grid-following and grid-forming), and both transmission and distribution systems.
13 April 2021 in IEEE Systems Journal
Rapid grid integration of inverter-interfaced distributed generators (DGs) and low-voltage ride-through capability of the smart inverter, as per IEEE 1547 standard, has made unintentional islanding detection (UID) cumbersome. Also, the feeder reconfiguration capability in meshed microgrids with multiple DGs has made the existing UID techniques ineffective. The methods have limitations in UID for small power mismatch conditions characterizing nondetection zone (NDZ). In hybrid methods for UID, a disturbance injection is continuous or for an extended period, which degrades the power quality (PQ) and creates stability issues. Hence, a decentralized closed-loop hybrid islanding detection method (HIDM) based on the indices extracted from the subcycle phaselet (passive) technique with limited-time (only for two cycles) $q$ -axis dc offset voltage injection (active) is proposed for UID of DGs. The proposed HIDM mitigates the NDZ due to the closed-loop scheme. Subcycle estimations from the phaselet technique result in quick UID and fault detection and classification process. Furthermore, the PQ issue is reduced due to the limited-time voltage injection (based only on the command from phaselet technique) in the proposed HIDM. Simulation results from the real-time digital simulator on a meshed microgrid and performance comparison with other existing methods prove the efficacy of the proposed HIDM.