1 March 2022 in Molecular Therapy
All retina-based vision restoration approaches rely on the assumption that photoreceptor loss does not preclude reactivation of the remaining retinal architecture. Whether extended periods of vision loss limit the efficacy of restorative therapies at the retinal level is unknown. We examined long-term changes in optogenetic responsivity of foveal retinal ganglion cells (RGCs) in non-human primates following localized photoreceptor ablation by high-intensity laser exposure. By performing fluorescence adaptive optics scanning light ophthalmoscopy (AOSLO) of RGCs expressing both the calcium indicator GCaMP6s and the optogenetic actuator ChrimsonR, it was possible to track optogenetic-mediated calcium responses in deafferented RGCs over time. Fluorescence fundus photography revealed a 40% reduction in ChrimsonR fluorescence from RGCs lacking photoreceptor input over the 3 weeks following photoreceptor ablation. Despite this, in vivo imaging revealed good cellular preservation of RGCs 3 months after the loss of photoreceptor input, and histology confirmed good structural preservation at 2 years. Optogenetic responses of RGCs in primate persisted for at least 1 year after the loss of photoreceptor input, with a sensitivity index similar to optogenetic responses recorded in intact retina. These results are promising for all potential therapeutic approaches to vision restoration that rely on preservation and reactivation of RGCs.
16 June 2025 in Biomedical Optics Express
Here, we demonstrate a telecentric model eye for measuring scanning, sampling, and optical distortion in AO ophthalmoscopes across a 10-diopter focus range, seeking to improve the reproducibility of adaptive optics (AO) ophthalmoscopy biomarkers. The model eye lens provides diffraction-limited performance when imaging with 800 nm light over circular 2.0, 3.0, 4.6, and 9.2° fields of view through 8, 6, 4, and 2 mm diameter aperture stops, respectively. Measurements of double-pass wavefront aberrations using both model and real retinas show that the use of opal glass model retinas, rough model retina surfaces, and wavefront sensing beacon scanning mitigate first-pass aberrations. This is particularly important, as first-pass aberrations are often assumed but not always achieved in AO ophthalmoscopes. Using the model eye with custom distortion estimation algorithms, we recorded 0.06% non-isotropic scaling repeatability, 0.02° shear repeatability, 0.5% reproducibility for both metrics and a root-mean-square residual distortion of 0.1 pixels across the field of view and focus range.
8 January 2026 in Biomedical Optics Express
We describe a refractive adaptive optics scanning light ophthalmoscope designed for small animal imaging through a 1.8 mm diameter pupil. The optical setup, based on a search of achromatic doublets through multiple lens catalogs, consists of a sequence of modified afocal relays that deliver diffraction-limited imaging in pupil and retina conjugates. Real ray tracing is used to compare imaging performance when correcting large focus errors using a pupil conjugate wavefront corrector, a traditional Badal optometer, and a modified Badal optometer. Polarization control, focal length selection, and systematic lens tilting are explored for mitigating reflections with minimal imaging performance degradation. A 2-dimensional optical scanner with a 29.2 kHz resonant frequency around one axis and low dynamic surface distortion allows doubling the frame rate of prior instruments and simplifies the optical setup. Scanner orientation and trigger electrical signals are used to correct sinusoidal image warping and line sampling jitter. The instrument is demonstrated by imaging mice under 800 nm illumination with two reflectance detection modalities: confocal and quadrant non-confocal.
17 July 2025 in Applied Optics
A low-cost non-contact method for placement of optical elements with or without optical power, as well as opto-mechanical elements along an optical axis, is demonstrated. This approach utilizes a camera mounted on a linear stage to capture images of surface imperfections illuminated by oblique incoherent light. Two variations of the method allow placing elements at nominal distances, while a third variation allows active focusing to account for radius errors in elements with power.
22 April 2026 in Biomedical Optics Express
We present an automated montaging method for distortion-corrected single- and multi-channel adaptive optics ophthalmoscope images. The approach employs a zero-mean normalized weighted cross-correlation (ZNWCC) that enables assigning real-valued pixel weights to account for irregular image boundaries, spatially varying signal-to-noise ratio, and motion of retinal features. An initial sub-pixel pairwise registration using translation, rotation, and, if needed, scaling is refined with a global registration quality metric derived from peak ZNWCC values. The images are montaged through weighted averaging and contrast stretching that equalize mean image brightness and contrast in overlapping regions, compensating for differences in overall illumination, detector offset, and detector gain. A final montage is created by combining the transformed images calculated through a single interpolation to mitigate loss of resolution, and with an optional polynomial field-flattening step to increase contrast throughout the montage. The method is demonstrated on AO retinal image sets from human and mouse eyes.
24 December 2025 in Biomedical Optics Express
Here, we propose optomechanical devices for steering anesthetized animals during retinal imaging and/or stimulation with stationary ophthalmoscopes. Simple operating procedures ensure that the entrance pupil of the eye remains centered on the exit pupil of the ophthalmoscope during steering, to avoid vignetting. The devices, built with commercially available manual linear stages and motorized rotating devices, can be used to capture image sequences for tiling, as is often done in microscopy. This automated steering system, demonstrated here in mice, is applicable to other animal species and imaging modalities, as well as explanted eyes. The use of these devices can reduce imaging time and retinal light exposure, both of which are important when using ophthalmoscopes with small fields of view, such as adaptive optics ophthalmoscopes, while also improving animal welfare.