Yuning Xia

Yuning Xia

Auto-generated profile, based on publicly available information

Yuning Xia

Institute of Optics, University of Rochester

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
KKKarteek Kunala
Karteek Kunala
YXYuning Xia
Yuning Xia
GAGastón A. Ayubi
Gastón A. Ayubi
BKBartlomiej Kowalski
Bartlomiej Kowalski
ADAnkur X. Desai
Ankur X. Desai
ADAlfredo Dubra
Alfredo Dubra
We describe a refractive adaptive optics scanning light ophthalmoscope designed for small animal imaging through a 1.8 mm diameter pupil. The optical setup, based on a search of achromatic doublets through multiple lens catalogs, consists of a sequence of modified afocal relays that deliver diffraction-limited imaging in pupil and retina conjugates. Real ray tracing is used to compare imaging performance when correcting large focus errors using a pupil conjugate wavefront corrector, a traditional Badal optometer, and a modified Badal optometer. Polarization control, focal length selection, and systematic lens tilting are explored for mitigating reflections with minimal imaging performance degradation. A 2-dimensional optical scanner with a 29.2 kHz resonant frequency around one axis and low dynamic surface distortion allows doubling the frame rate of prior instruments and simplifies the optical setup. Scanner orientation and trigger electrical signals are used to correct sinusoidal image warping and line sampling jitter. The instrument is demonstrated by imaging mice under 800 nm illumination with two reflectance detection modalities: confocal and quadrant non-confocal.

29 January 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
YXYuning Xia
Yuning Xia
GAGastón A. Ayubi
Gastón A. Ayubi
JBJulie Bentley
Julie Bentley
ADAlfredo Dubra
Alfredo Dubra
Here we present the design of telecentric model eyes for measuring image distortion in adaptive optics ophthalmoscopes, using pairs of achromatic or near-achromatic commercial off-the-shelf (COTS) and/or custom doublet lenses. The proposed model eyes can operate over visible or visible plus near infrared wavelength ranges, across a 15-diopter focus range, with an 8 mm entrance pupil diameter. COTS lens selection was implemented as a systematic evaluation of catalog lenses after optimization of axial distances. Custom lens optimization was initially guided by wavefront aberration constraints derived from object-shift 3 rd order aberration theory, before traditional variation of surfaces and distances to minimize a performance metric. When a wavefront corrector compensates for field-constant aberrations, the model eyes achieve nominal wavefront RMS below λ/20 across a ∼6.9° circular full field of view for COTS and hybrid lens pairs, limited by vignetting from a self-imposed 27.9 mm clear aperture. For custom lens pairs, the field of view is about 10.2°, limited by aberrations. A tolerance study indicates that a COTS lens pair for 450-1100 nm can achieve as-built diffraction-limited wavefront error of 0.044 λ @450 nm at 95% production yield. Model eyes with this lens pair yielded telecentricity quantified as image size changed per diopter of 0.1%/D when assembled with a camera and 0.01%/D when assembled with a power meter. The model eye was tested with an optical setup that emulates a fundus camera with Badal focus correction.

24 July 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
SSSamuel Steven
Samuel Steven
YXYuning Xia
Yuning Xia
JBJulie Bentley
Julie Bentley
ADAlfredo Dubra
Alfredo Dubra
Here we present an adaptive optics scanning light ophthalmoscope with a square 1.5° full field of view, steerable within a 4° window. When imaging through a 7.72 mm diameter pupil, the instrument provides nominal diffraction-limited performance at the retinal conjugate over a 20 diopter (D) focus range centered at 1D of myopia and supports a 3 D source-detector vergence range for any combination of wavelengths between 450 and 1300 nm. The optical setup also provides nominal diffraction-limited imaging between the pupil conjugates of the wavefront sensor, deformable mirror, and eye, with distortion below 0.5% across the 3 D source-detector vergence range. The optical setup includes four pupil relays. The first three are telescopes formed by pairs of concave spherical mirrors tilted in a non-planar configuration. In these relays, the mirror-to-mirror spacing was held fixed, while the distances to the entrance and exit pupil planes were varied to mitigate aberrations in both pupil and retinal conjugates. The fourth relay comprises four spherical mirrors, two concave and two convex, tilted in a planar configuration. As-built instrument performance is demonstrated by imaging a telecentric model eye over a -6 to +8 D range (limited by deformable mirror stroke) and human photoreceptor mosaic imaging at 680 and 795 nm. The proposed relay forms are broadly applicable to adaptive optics ophthalmoscopes and imaging modalities, including fluorescence, spectroscopy, and optical coherence tomography

21 October 2026 in Biomedical Optics Express
Verified
Journal Article
Closed access
GAGastón A. Ayubi
Gastón A. Ayubi
KKKarteek Kunala
Karteek Kunala
YXYuning Xia
Yuning Xia
ADAlfredo Dubra
Alfredo Dubra
We propose using a custom glass wedge in reflection to generate two illumination beams for implementing strabismic imaging in point- and line-scanning imaging instruments. We present wedge design formulae that ensure beam overlap at pupil conjugates while achieving a desired beam separation at image conjugates. These formulae provide, for an in-plane wedge rotation, the rotation angle of the primary reflection from the second wedge surface about the primary reflection from the first surface, and the resulting small residual separation at pupil conjugates. We demonstrate the approach in an adaptive optics scanning light ophthalmoscope with reflectance confocal and non-confocal imaging channels. This low-cost, low-complexity method for generating strabismic illumination from a single collimated beam provides long-term mechanical stability and is broadly applicable across imaging modalities.