Christopher Ceroici

Christopher Ceroici

Auto-generated profile, based on publicly available information

Christopher Ceroici

Department of Electrical and Computer Engineering, University of Alberta, Edmonton, AB, Canada

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2020 in Optics Express
Verified
Journal Article
Closed access
AIAfshin Kashani Ilkhechi
Afshin Kashani Ilkhechi
CCChristopher Ceroici
Christopher Ceroici
ZLZhenhao Li
Zhenhao Li
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Photoacoustic imaging has shown great potential for non-invasive high-resolution deep-tissue imaging. Minimizing the optical and acoustic paths for excitation and detection could significantly increase the signal-to-noise ratio. This could be accomplished by transparent transducers permitting through-transducer illumination. However, most ultrasound transducers are not optically transparent. Capacitive micromachined ultrasound transducer (CMUT) technology has compelling properties compared to piezoelectric transducers such as wide bandwidth and high receive sensitivity. Here, we introduce transparent CMUT linear arrays with high transparency in the visible and near-infrared range. To fabricate the devices, we used an adhesive wafer bonding technique using photosensitive benzocyclobutene (BCB) as both a structural and adhesive layer with a glass-indium-tin-oxide (ITO) substrate. Silicon nitride is used as the membrane material ensuring hermiticity and optical transparency. Our fabricated transducer arrays consist of 64 and 128 elements with immersion operation frequency of 8 MHz, enabling high-resolution imaging. ITO, along with thin metal strips, are used as a conductive layer for the top electrodes with minimal impact on device transparency. Fabricated devices have shown average transparency of 70% in the visible wavelength range that goes up to 90% in the near-infrared range. Arrays are wire-bonded to interfacing electronics and connected to a research ultrasound platform for phantom imaging. Arrays exhibited signal-to-noise (SNR) of 40 dB with 30V bias voltage and laser fluence of 13.5 mJ/cm2. Arrays with 128 channels provided lateral and axial resolutions of 234 µm and 220 µm, respectively.

23 March 2017 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Open access
CCChris Ceroici
Chris Ceroici
THTyler Harrison
Tyler Harrison
RZRoger J. Zemp
Roger J. Zemp
Recently, top-orthogonal-to-bottom electrode 2-D arrays were introduced as a practical design for 3-D ultrasound imaging without requiring the wiring of a 2-D grid of elements. However, previously proposed imaging schemes suffered from speed or image-quality limitations. Here, we propose a new imaging scheme which we call Fast Orthogonal Row-Column Electronic Scanning (FORCES). This new approach takes advantage of bias sensitivity to enable high-quality and fast B-scan imaging. We compare this imaging scheme with an equivalent linear array, a previously proposed row-column imaging scheme, as well as with the Explososcan imaging scheme for 2-D arrays through simulations. In a point phantom simulation, the lateral (azimuthal) resolution of a 64 × 64 element 6.67-MHz λ/2-pitch array using the FORCES imaging scheme with an f-number of 1.7 was 0.52 mm with similar in-plane image quality to an equivalent linear array but with improved and electronically steerable elevational resolution. When compared with other 3-D imaging schemes in point phantom simulations, the FORCES imaging scheme showed an azimuthal resolution improvement of 54% compared with Explososcan. Compared with a previously introduced row-column method, the FORCES imaging scheme had similar resolution but a 25-dB decrease in sidelobe amplitude, significantly impacting contrast to noise in scattering phantoms.

19 March 2021 in Optics Letters
Verified
Journal Article
Closed access
PDF file
AIAfshin Kashani Ilkhechi
Afshin Kashani Ilkhechi
CCChristopher Ceroici
Christopher Ceroici
EDEric Dew
Eric Dew
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Transparent ultrasound transducers could enable many novel applications involving both ultrasonics and optics. Recently, we reported transparent capacitive micromachined ultrasound transducers (CMUTs) and demonstrated through-illumination photoacoustic imaging. This work presents the feasibility of transparent CMUTs for combined ultrasound imaging and through-array white-light imaging with a miniature camera placed behind the array. Transparent CMUT devices are fabricated with an adhesive wafer bonding technique and provide high transparency up to 90% in visible wavelengths. Fabricated linear arrays have a central operating frequency of 9 MHz with 128 active elements. Realtime plane-wave imaging is performed for ultrasound imaging, and lateral and axial resolutions of, respectively, 234 and 338 µm are achieved. Transparent CMUT has demonstrated a high transmit sensitivity of 1.4 kPa/V per channel with a 100 VDC bias voltage. The signal-to-noise ratio for a beamformed image of wire targets is determined to be 28.4 dB. To the best of our knowledge, this is the first report of combined realtime optical and ultrasonic imaging with transparent arrays. This technology may enable one to visually see what is being scanned and scan what one sees without co-registration errors. Future applications could include multi-modality probes for interventional and surgical procedures.

24 February 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MMMohammad Maadi
Mohammad Maadi
CCChristopher Ceroici
Christopher Ceroici
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Dual-frequency capacitive micromachined ultrasonic transducers (CMUTs) are introduced for multiscale imaging applications, where a single array transducer can be used for both deep low-resolution imaging and shallow high-resolution imaging. These transducers consist of low- and high-frequency membranes interlaced within each subarray element. They are fabricated using a modified sacrificial release process. Successful performance is demonstrated using wafer-level vibrometer testing, as well as acoustic testing on wirebonded dies consisting of arrays of 2- and 9-MHz elements of up to 64 elements for each subarray. The arrays are demonstrated to provide multiscale, multiresolution imaging using wire phantoms and can span frequencies from 2 MHz up to as high as 17 MHz. Peak transmit sensitivities of 27 and 7.5 kPa/V are achieved with the low- and high-frequency subarrays, respectively. At 16-mm imaging depth, lateral spatial resolution achieved is 0.84 and 0.33 mm for low- and high-frequency subarrays, respectively. The signal-to-noise ratio of the low-frequency subarray is significantly higher for deep targets compared to the high-frequency subarray. The array achieves multiband imaging capabilities difficult to achieve with current transducer technologies and may have applications to multipurpose probes and novel contrast agent imaging schemes.

20 March 2019 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
CCChris Ceroici
Chris Ceroici
KLKatherine Latham
Katherine Latham
BGBenjamin A. Greenlay
Benjamin A. Greenlay
JBJeremy A. Brown
Jeremy A. Brown
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
Three-dimensional ultrasound imaging presents technical challenges of addressing large numbers of elements in 2D array transducers. Top-Orthogonal to Bottom Electrode (TOBE) 2D transducer arrays can simplify addressing but typical imaging methods with such arrays enable only one-way focusing in azimuth and elevation. Here experimental results are reported for the Fast Orthogonal Row-Column Electronic Scanning (FORCES) imaging scheme implemented on a 64 ×64 element bias-sensitive electrostrictive relaxor TOBE array. The FORCES imaging scheme involves transmitting along rows to form an elevational transmit focus, while biasing columns with bias patterns selected from a Hadamard matrix. Channel data from columns is received and decoded for synthetic aperture beamforming in azimuth. This scheme offers two-way azimuthal focusing. Volumetric imaging experiments were conducted using wire phantoms as well as on rat hearts using two different TOBE imaging schemes: Scheme 1 (transmit focusing in elevation and receive focusing in azimuth) and FORCES. Wire phantom experiments at a depth of 2 cm showed an azimuthal resolution of 0.42 mm and 0.31 mm with Scheme 1 and FORCES, respectively. We also compared the elevational imaging performance of these imaging schemes with a mechanically scanned linear array. The FORCES imaging displayed an elevational resolution of 0.46 mm at a depth of 2 cm and the linear array an elevational resolution of 0.72 cm. The novel TOBE array architecture and FORCES imaging scheme thus enable high-quality 3D ultrasound imaging using only row-column addressing and bias control, and may prove an enabling technology for many future 3D imaging platforms.

28 June 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
KLKatherine Latham
Katherine Latham
CCChris Ceroici
Chris Ceroici
CSChristopher A. Samson
Christopher A. Samson
RZROGER JAMES ZEMP
ROGER JAMES ZEMP
JBJeremy A. Brown
Jeremy A. Brown
We have developed a new, fast and simple 3D imaging approach referred to as Simultaneous Azimuth and Fresnel Elevation (SAFE) compounding using a bias-sensitive crossed-electrode array. The principle behind this technique is to perform conventional plane wave compounding with a back set of electrodes, while implementing a reconfigurable Fresnel elevation lens with an orthogonal set of front electrodes. While a Fresnel lens would usually result in unacceptable secondary lobe levels, these lobes can be suppressed by compounding different Fresnel patterns. The azimuthal and elevational planes can be simultaneously compounded to increase the beam quality with no loss in frame rate. A 10 MHz, 64x64 element crossed electrode relaxor array was fabricated on a electrostrictive 1-3 composite substrate to demonstrate the SAFE compounding approach. The electrostrictive composite array has a measured electromechanical coupling coefficient (kt) of 0.62 with a bias voltage of 90V and a measured two-way pulse bandwidth of 60%. The electrical impedance magnitude of array elements on resonance was measured to be 90 ohms with a phase angle of -35 degrees. Radiation patterns were simulated showing a -6 dB beamwidth of 330 microns with secondary lobe levels suppressed more than -60 dB in the azimuth dimension, and a -6 dB beamwidth of 450 microns with secondary lobe levels suppressed to -50 dB in the elevation dimension after 64 compounds. Experimental radiation patterns were collected and found to be in good agreement with simulations. Experimental 3D images of wire phantoms were collected using a Verasonics Experimental Ultrasound System.