7 June 2021 in Journal of Structural Integrity and Maintenance
The traditional means of using precast concrete sandwich panels are restrictive in terms of applications, where thick wythes result in heavy panels which are often unsuitable in retrofitting domestic and commercial buildings. As concrete sandwich panel technology has evolved to make it more widely accessible, recent research work has demonstrated that it is possible to achieve thermally efficient partial composite action within a thin wythe panel provided non-conductive shear connectors are used. This paper examines high performance recycled aggregate concrete in heavily insulated non-load-bearing panels for retrofitting domestic and commercial buildings. A series of concrete mixes were tested to develop one which would be more sustainable than the widely accepted standard mixes for wythes. Different 220 mm thick concrete sandwich panels were tested consisting of 20 mm thick fibre-reinforced recycled aggregate concrete wythes and a 180 mm layer of XPS insulation. Unconnected and shear connected panels were tested in flexure in a displacement control test. The effects of composite action and post-cracking toughness were examined and it was concluded that a shear connected panel comprising sustainable thin recycled aggregate concrete wythes enclosing a thick layer of insulation is a feasible product to use for light high-performance sandwich panels.
9 August 2024 in Recent Progress in Materials
This paper describes a method to use solely recycled and by-product materials as constituents to form concrete that can be used in buildings structural applications. As concrete is one of the most important materials in human civilization, where it is used widely in construction, cement and aggregate the main components of concrete cause an emission of large amounts of carbon dioxide, which is the main cause of global warming. The production of one tonne of cement, for example, causes the emission of about 800 kg of this CO2. The growing demand for concrete constitutes a threat to the environment and its resources into the future. According to a market study by The Freedonia Group, in 2019 the world demand for cement was 5.1 billion tonnes which means that more than 2.5 billion tonnes of water and more than 11 billion tonnes of aggregates, both of which are scarce resources, will also be consumed. The goal of this Paper is to describe a 100% substitution of concretes normal constituents to form a sustainable concrete with zero carbon footprint and without compromising concrete mechanical properties. This will demand a pre-treatment of the recycled and by-products components to compensate for the natural strength loss due to their inclusion. Therefore, an innovative novel treatment method is selected for recycled concrete aggregates and chipped rubber to be separately treated and tested to mitigate the loss of strength in proposing a novel recycled activator for GGBS and silica fume. Then these waste recyclable materials are combined in a concrete mix that is 100% recycled and, therefore, significantly more sustainable.
3 April 2017 in Journal of Structural Integrity and Maintenance
This paper describes some of the extensive outcomes of a structural load test on a full-scale bamboo-epoxy composite frame. A bundle of 30 small diameter thick-walled bamboo culms was bonded using an epoxy-fibre resin to form structural beam and column elements, which were connected at the beam/column joints using rebar and a novel composite glue to form a Portal frame. The frame was heavily instrumented with over 90 strain gauges to establish the locations of any delaminations or hinge formations during inelastic behaviour under load. The frame and the gauges were assembled in India and shipped to Ireland for testing. In Trinity College Dublin, the frame was supported by steel shoes bolted to a 3000 kN internal reaction rig, with additional passive lateral supports in case of out-of-plane instability during loading. This paper describes the load–displacement response under combined horizontal and vertical loading, together with an explanation of the frame’s non-linear behaviour using the evidence provided by the strain gauges, including the development of significant secondary moments due to the frame’s flexibility. The residual load capacity of the frame was evident whereupon significant inelastic deformations occurred as the actuator heads were allowed to continue to distort the frame under a sustained load.