22 August 2018 in IEEE Transactions on Medical Imaging
Intra-arterial liver cancer therapies such as transarterial chemoembolization (TACE) are the preferred therapeutic approaches for advanced hepatocellular carcinoma (HCC). However, these palliative techniques are challenging for delivering therapeutic agents selectively in the tumor without real-time 3D visualization of the catheter within the hepatic arteries. The objective of this work is to develop and evaluate in preclinical tests an advanced interventional guidance platform using a distributed strain sensing device based on optical frequency domain reflectometry (OFDR) to track the tip and shape of a catheter. The scattering properties of a fiber triplet are enhanced by focusing an ultraviolet beam on these fibers, producing a fully-distributed strain sensor, which avoids interpolation errors observed with traditional shape tracking systems. A 3D roadmap of the hepatic arteries is obtained from a combined fully convolutional and residual networks trained on MR angiography, and combined with a 4D flow dynamic sequence enabling to map blood flow velocities. An anisotropic curvature matching method is proposed to map the sensed data onto pre-operative MR and using 3D ultrasound to correct for non-rigid deformations. Experiments were conducted in a controlled environment setting, as well as in both synthetic phantoms and in 5 porcine models to assess the performance for device navigation, yielding satisfactory tracking accuracy with 3D mean errors of 2.8 ± 0.9 mm. We present the first pilot study of MR-compatible UV-exposed OFDR optical fibers for non-ionizing device guidance in intra-arterial procedures, with the potential of avoiding multiple hospitalizations required to perform invasive selective chemoembolizations.
30 April 2019 in Optics Express
We propose a novel device defined as Random Optical Grating by Ultraviolet or ultrafast laser Exposure (ROGUE), a new type of fiber Bragg grating (FBG), exhibiting a weak reflection over a large bandwidth, which is independent of the length of the grating. This FBG is fabricated simply by dithering the phase randomly during the writing process. This grating has an enhanced backscatter, several orders of magnitude above typical Rayleigh backscatter of standard SMF-28 optical fiber. The grating is used in distributed sensing using optical frequency domain reflectometry (OFDR), allowing a significant increase in signal to noise ratio for strain and temperature measurement. This enhancement results in significantly lower strain or temperature noise level and accuracy error, without sacrificing the spatial resolution. Using this method, we show a sensor with a backscatter level 50 dB higher than standard unexposed SMF-28, which can thus compensate for increased loss in the system.
1 May 2020 in IEEE International Conference on Robotics and Automation (ICRA)
Flexible medical instruments, such as Continuum Dexterous Manipulators (CDM), constitute an important class of tools for minimally invasive surgery. Accurate CDM shape reconstruction during surgery is of great importance, yet a challenging task. Fiber Bragg grating (FBG) sensors have demonstrated great potential in shape sensing and consequently tip position estimation of CDMs. However, due to the limited number of sensing locations, these sensors can only accurately recover basic shapes, and become unreliable in the presence of obstacles or many inflection points such as s-bends. Optical Frequency Domain Reflectometry (OFDR), on the other hand, can achieve much higher spatial resolution, and can therefore accurately reconstruct more complex shapes. Additionally, Random Optical Gratings by Ultraviolet laser Exposure (ROGUEs) can be written in the fibers to increase signal to noise ratio of the sensors. In this comparison study, the tip position error is used as a metric to compare both FBG and OFDR shape reconstructions for a 35 mm long CDM developed for orthopedic surgeries, using a pair of stereo cameras as ground truth. Three sets of experiments were conducted to measure the accuracy of each technique in various surgical scenarios. The tip position error for the OFDR (and FBG) technique was found to be 0.32 (0.83) mm in free-bending environment, 0.41 (0.80) mm when interacting with obstacles, and 0.45 (2.27) mm in s-bending. Moreover, the maximum tip position error remains sub-millimeter for the OFDR reconstruction, while it reaches 3.40 mm for FBG reconstruction. These results propose a cost-effective, robust and more accurate alternative to FBG sensors for reconstructing complex CDM shapes.
23 June 2021 in Scientific Reports
JBJean-Sébastien Boisvert
A simple novel method for random number generation is presented, based on a random Raman fiber laser. This laser is built in a half-open cavity scheme, closed on one side by a narrow-linewidth 100 mm fiber Bragg grating. The interaction between the randomly excited lasing modes of this laser, in addition to nonlinear effects such as modulation instability, allow the generation of random bits at rates of up to 540 Gbps with minimal post processing. Evaluation of the resulting bit streams’ randomness by the NIST statistical test suite highlights the importance of evaluating the physical entropy content, as bit sequences generated by this random laser pass all the statistical tests with a significance level of 0.01, despite being generated at more than twice the theoretical entropy generation speed.
28 November 2022 in IEEE Transactions on Biomedical Engineering
Objective: Minimally invasive revascularization procedures such as percutaneous transluminal angioplasty seek to treat occlusions in peripheral arteries. However their ability to treat long occlusions are hampered by difficulties to monitor the location of intravascular devices such as guidewires using fluoroscopy which requires continuous radiation, and lack the capacity to measure physiological characteristics such as laminar blood flow close to occlusions. Fiber optic technologies provide means of tracking by measuring fibers under strain, however they are limited to known geometrical models and are not used to measure external variations. Methods: We present a navigation framework based on optical frequency domain reflectometry (OFDR) using fully-distributed optical sensor gratings enhanced with ultraviolet exposure to track the three-dimensional shape and surrounding blood flow of intra-vascular guidewires. To process the strain information provided by the continuous gratings, a dual-branch model learning spatio-temporal features allows to predict the output measures based on scattered wavelength distributions. The first network determines the 3D shape appearance of the guidewire using the input backscattered wavelength shift data in combination with prior segmentations, while a second network (graph temporal convolution network) produces estimates of vascular flow velocities using ground-truth 4D-flow MRI acquisitions. Results: Experiments performed on synthetic and animal models, as well as in a preliminary human trial shows the capability of the model to generate accurate 3D shape tracking and blood flow velocities differences below 2 cm/s, thus providing realistic physiologic and anatomical properties for intravascular techniques. Conclusion and Significance: The study demonstrates the feasibility of using the device clinically, and could be integrated within revascularization workflows for treating occlusions in arteries, since the navigation framework involves minimal manual intervention.
16 May 2023 in Scientific Reports
In the current article, we use a random supercontinuum based on a random Raman distributed feedback laser to investigate the generation of random numbers by spectrally demultiplexing the broad supercontinuum spectrum in parallel channels. By tuning the spectral separation between two independent channels, we test the most typically used statistical tests’ abilities to identify the required minimum spectral separation between channels, especially after the use of post-processing steps. Out of all the tests that were investigated, the cross-correlation across channels using the raw data appears to be the most robust. We also demonstrate that the use of post-processing steps, either least significant bits extraction or exclusive-OR operations, hinders the ability of these tests to detect the existing correlations. As such, performing these tests on post-processed data, often reported in literature, is insufficient to properly establish the independence of two parallel channels. We therefore present a methodology, which may be used to confirm the true randomness of parallel random number generation schemes. Finally, we demonstrate that, while tuning a single channel’s bandwidth can modify its potential randomness output, it also affects the number of available channels, such that the total random number generation bitrate is conserved.