1 February 2022 in Clays and Clay Minerals
Diagenetic illite growth in porous sandstones leads to significant modifications of the initial pore system which result in tight reservoirs. Understanding and quantifying these changes provides insight into the porosity-permeability history of the reservoir and improves predictions on petrophysical behavior. To characterize the various stages of diagenetic alteration, a focused ion beam – scanning electron microscopy (FIB-SEM) study was undertaken on aeolian sandstones from the Bebertal outcrop of the Parchim Formation (Early Permian Upper Rotliegend group). Based on 3D microscopic reconstructions, three different textural types of illite crystals occur, common to many tight Rotliegend sandstones, namely (1) feldspar grain alterations and associated illite meshworks, (2) tangential grain coats, and (3) pore-filling laths and fibers. Reaction textures, pore structure quantifications, and numerical simulations of fluid transport have revealed that different generations of nano-porosity are connected to the diagenetic alteration of feldspars and the authigenic growth of pore-filling illites. The latter leads to the formation of microstructures that range from authigenic compact tangential grain coatings to highly porous, pore-filling structures. K-feldspar replacement and initial grain coatings of illite are composed primarily of disordered 1Md illite whereas the epitaxially grown illite lath- and fiber-shaped crystals occurring as pore-filling structures are of the trans-vacant 1Mtv polytype. Although all analyzed 3D structures offer connected pathways, the largest reduction in sandstone permeability occurred during the initial formation of the tangential illite coatings that sealed altered feldspars and the subsequent growth of pore-filling laths and fibrous illites. Analyses of both illite pore-size and crystallite-size distributions indicate that crystal growth occurred by a continuous nucleation and growth mechanism probably controlled by the multiple influx of potassium-rich fluids during late Triassic and Jurassic times. The detailed insight into the textural varieties of illite crystal growth and its calculated permeabilities provides important constraints for understanding the complexities of fluid-flow in tight reservoir sandstones.
20 November 2024 in Clays and Clay Minerals
Transmission electron microscopy-energy dispersive X-ray analysis (TEM-EDX) represents an effective tool for determining the stoichiometric composition of clay minerals, but the methodology is often hampered by analytical difficulties. Studies of beam-sensitive minerals, such as smectites, are associated with low count intensities and dynamic loss of cations (e.g. K+, Na+, and Al3+), which can lead to erroneous quantifications of composition. After exploring how to minimize cation migration by reducing the beam current density to 10,000 cps) were acquired. Based on 528 TEM-EDX area analyses, the composition of Wyoming montmorillonites (SWy-1, SWy-2, and SWy-3) was studied in their natural and Ca-saturated states from thin (<50 nm thick) particle aggregates lying on lacey carbon films. Overall, the TEM-EDX results confirmed the heterogeneous charge distributions of montmorillonite at the particle and sample levels. The average composition per formula unit of SWy-1 to -3 was determined as: (Na0.12Ca0.04Mg0.03K0.02)(Si3.91Al0.09)(Al1.57Mg0.27Fe0.19)2.03 O10(OH)2 · nH2O, where the tetrahedral and octahedral layer charges are –0.09 and –0.19 per O10(OH)2, respectively, and the total layer charge ranges from –0.25 to –0.30 per O10(OH)2 (mean of –0.28). This study demonstrates how TEM-EDX can provide new insight into the natural heterogeneities of smectite chemistry as long as adequate calibration and specimen damage control procedures are implemented.
27 October 2023 in Rapid Communications in Mass Spectrometry
Rationale: Clumped isotope (Δ 47 ) analysis of bioapatite‐derived CO 2 is a powerful tool to determine body temperatures of extinct vertebrates. The common acid bath technique in combination with dual‐inlet‐based mass spectrometric measurements has been the preferred method of choice for this purpose, but the large amount of material necessary and the presence of secondary calcite represent obstacles. Methods: We analyzed the Δ 47 composition of carbonate‐bearing (bio)apatites using a Kiel IV device, which – in general – allows a reduction of sample replicate size by a factor of ~40 over dual‐inlet‐based techniques. The Kiel IV device was tested in two different modes: without and with additional water sinks for improved water removal. Furthermore, we tested a pretreatment technique based on 1 M acetic acid (pH = 5) to selectively remove secondary calcite from the carbonate‐bearing (bio)apatite phase. Results: Significantly lower Δ 47 values were obtained for a given bioapatite after the installation of the two water sinks. With this setup, Δ 47 of (bio)apatites followed a temperature relationship that is indistinguishable from the unified one for pure carbonates, provided a dentine sample, rich in organic matter, was excluded. The original bioapatite Δ 47 value was restored from a bioapatite/calcite mixture if the mixed material was treated for 1 h with 1 M acetic acid (pH = 5). Conclusions: (Bio)apatites having low organic matter content such as enamel(oid) can be analyzed accurately for Δ 47 using a Kiel IV equipped with water sinks that ensure effective removal of water. Secondary calcite can be effectively removed from carbonate‐bearing apatite by pretreatment with 1 M acetic acid (pH = 5) for 1 h.
19 February 2023 in SN Applied Sciences
There is a current need for developing improved synthetic porous materials for better constraining the dynamic and coupled processes relevant to the geotechnical use of underground reservoirs. In this study, a low temperature preparation method for making synthetic rocks is presented that uses a geopolymer binder cured at 80 °C based on alkali-activated metakaolin. For the synthesised sandstone, the key rock properties permeability, porosity, compressive strength, and mineralogical composition, are determined and compared against two natural reservoir rocks. In addition, the homogeneity of the material is analysed structurally by micro-computed tomography and high-resolution scanning electron microscopy, and chemically by energy dispersive X-ray spectroscopy. It is shown that simple, homogenous sandstone analogues can be prepared that show permeability-porosity values in the range of porous reservoir rocks. The advance in using geopolymer binders to prepare synthetic sandstones containing thermally sensitive minerals provides materials that can be easily adapted to specific experimental needs. The use of such material in flow-through experiments is expected to help bridge the gap between experimental observations and numerical simulations, leading to a more systematic understanding of the physio-chemical behaviour of porous reservoir rocks.