30 June 2023 in Eastern-European Journal of Enterprise Technologies
The object of research is energy processes in a hybrid photovoltaic system with a storage battery for the needs of a local object involving the setting of power consumed from the network. The task addressed was to build a mathematical model of energy processes with the function of determining control parameters providing for the possibility of changing control scenarios. The mathematical model of the storage battery has been improved, taking into account the charge modes and discharge currents in terms of accuracy of reproduction of the manufacturer’s specification not worse than 3 %. A structure of the model was proposed with separation of module, which defines control parameters, as well as the schedule of power setting for selected scenarios. A variable is introduced into the model description, which determines the specified power value and ensures the construction of SoС(t) schedule. An additional mode to increase the energy use of the photovoltaic battery and restrictions on the measured value of load power were taken into account. Modeling with a change in time scale was proposed: first, control parameters are determined, followed by modeling in the daily cycle. This eliminates the need for preliminary calculations before modeling and provides the ability to verify the determination of system parameters with subsequent adjustment. A procedure for determining control parameters with power setting and adjusting the model under different control scenarios has been devised. When using archival generation data for the location of the facility, this makes it possible at the design stage to choose an option for implementing the power supply system with the desired indicators. For specific uses, it has been shown that underestimating the power of a photovoltaic battery by only 9 % increases energy costs by 1.72–1.39 times. Overstating power by 16.7 % impairs usage by 13.7 % while reducing costs by 1.4 % to 2.5 %
24 September 2024 in Archives of Electrical Engineering
The technique of estimating the expected decrease in electricity consumption from the grid and using PV energy for the taken load schedule based on archival data for 5 years is refined. With full self-consumption (SC), the reduction of consumption from the grid can be increased by 9.5%–30.7% for a year according to the rated PV power. Consumption should increase when PV generation exceeds a certain value. A discrete time control of the power of an electric storage boiler (ESB) is proposed based on the deviation of the storage battery (SB) state of charge from a given schedule with a heating concentration during hours of high PV generation. In the considered application, it is possible to increase SC by up to 21%. Reducing the load in the evening allows us to use SB energy to reduce consumption from the grid at night. The possibility of complete photovoltaic SC when the ESB is used with an air conditioner is substantiated. Limitations for air conditioner energy consumption according to PV generation are determined. The system’s 24h model of energy processes is supplemented with a thermal model. The standard use of ESB with water temperature maintenance was also considered for comparison. ESB power control allows you to reduce daily energy consumption from the grid by 1.7–2 times. When combining an adjustable ESB with an air conditioner, it is possible to reduce consumption from the grid by 1.466–1.558 times at minimum and increase consumption from the grid by 2–5% at maximum air conditioner consumption.
4 January 2022 in Technologies and Engineering
Purpose. Improving the methodology for determining the parameters of a photoelectric system with a battery for the needs of a local object using archival data of the generation of a photoelectric battery with planning the cost of energy consumption from the network for all seasons of the year. Methodology. Using an archive of data on the power generation of a photoelectric battery and analysis of energy processes in a photoelectric system with a battery using computer simulation. Findings. Calculated according to the archive data for five years, the average monthly values of photoelectric battery generation power for time intervals during the day determined according to tariff zones. Dependencies to determine the recommended average value load power of a local object at time intervals. Originality. It is proposed to determine the base schedule of the local facility and the parameters of the photoelectric system based on the average monthly values of photoelectric battery generation in the transition seasons – October, March and the expected cost of energy consumed from the grid during the year. The recalculation of the base value of power during the year is substantiated taking into account the duration of daylight. A method for determining the recommended load schedule of a local object with the formation of the battery charge according to the average monthly value of the photoelectric battery generation power at time intervals during the day, which are determined by archival data for the object location. Practical value. The obtained solutions are the basis for designing photoelectric systems with a battery to meet the needs of local objects.
30 April 2021 in Eastern-European Journal of Enterprise Technologies
+This paper has considered improving the management of energy consumption by a photovoltaic system with a storage device for a local object connected to the network. The aim of the study is to reduce expenditures when paying for electricity consumed from the network, when loading an object, independent of the time of year, and to eliminate energy generation to the grid. An energy generation control algorithm has been improved whereby the state of battery charge during the day is based on a forecast. That could reduce electricity consumption at night with better utilization of rechargeable battery and photovoltaic battery power during the day. It is proposed to use autonomous operation by disconnecting from the network during peak tariff hours and during the day with enough energy generation by a photovoltaic battery. This would ensure the normal functioning of an object in the event of a possible deterioration in the quality of voltage in the network while reducing the loss of energy in the inverter. Predictive control of the expected battery charge at the next checkpoint (at 0.5 hours or less between control points) has been proposed. A control system structure has been developed whereby a rechargeable battery current is set depending on an operational mode, the tariff zone, and the projected generation by a photovoltaic battery while reducing the modulation frequency under an autonomous mode. In this case, the modes are switched and the structure is changed taking into consideration the state of battery charge. Simulation in the daily cycle has shown the possibility of reducing the cost of electricity consumed from the network by 1.7‒8 times at two or three tariff rates. Simulation of electromagnetic processes in the system confirms acceptable regulation indicators when switching the structure, as well as a decrease in the energy loss in an inverter under an autonomous mode by up to 40 %
30 October 2025 in Eastern-European Journal of Enterprise Technologies
This study mathematically models energy processes within the microclimate control system in a single-family house equipped with a reversible heat pump. This paper reports an improved model of the microclimate system considering the dynamics to construct plots of electricity consumption under various operating conditions. Data from the calculated thermal parameters of the building were applied. A model of the reversible heat pump has been proposed, based on manufacturer specifications, allowing for the assessment of electricity consumption across the full range of power and temperature variations. The microclimate system model of the building with a heat pump has been improved by accounting for the building’s thermal inertia. This makes it possible to evaluate temperature regimes and energy consumption under dynamic modes, bringing the simulated electricity usage closer to real-world values. Hourly profiles of solar radiation and outdoor temperature for the building’s location, along with expected schedules of internal heat gains, were used. Energy consumption and instantaneous power values, including peak loads, were assessed. It is shown that, for a building in Kyiv with a floor area of 120 m2, under a heating mode, minimum electricity consumption occurs at a minimum heat carrier temperature of 35°C at a COP of 3.44. The selected heat pump may operate under a monovalent mode down to –13°C. The potential for reducing energy consumption by adjusting the temperature regime is limited because of a significant increase in power demand from the heat pump under a dynamic mode. Under a cooling mode, hourly air temperature profiles from historical data were used, along with representative values, to evaluate the range of energy consumption variation. An example involving changes in window area demonstrates the model’s applicability for adjusting building parameters to reduce energy consumption
10 October 2024 in Journal of Electrical and power engineering
SDState Institution of Higher Education «Kiev National University of Technologies and Design»
State Institution of Higher Education «Kiev National University of Technologies and Design»
The article considers the improvement of the control with using the generation of renewable energy sources forecast for a grid-connected a hybrid power supply system of a livestock farm with electric transport and a gas generator. The task is to form a graph of the state of charge of the main battery with a limitation of the depth of discharge with the maximum use of renewable sources energy. The calculation method of the state of charge of a battery and power consumption graph when working with the grid and in autonomous mode has been improved, with the definition of recommendations for charging electric transport. A mechanism has been developed for correcting the power consumption based on the deviation of the battery charge state relative to the specified value, with the correction disabled to implement the function of eliminating the export of excess energy to the grid or gas generator. This ensures the limitation of the gas generator power within certain limits and helps to limit the influence of generation and load deviations relative to the forecast on the battery discharge depth. The structure of the energy processes model in the system for the daily operation cycle has been developed. In the process of modeling, the deviation of renewable energy generation up to 20% and 10% was studied simultane-ously with a 10% increase in load.