The motivation to improve components in electric power equipment brings new proposals from world-renowned scientists to strengthen them in operation. An essential part of every electric power equipment is its insulation system, which must have the best possible parameters. The current problem with mineral oil replacement is investigating and testing other alternative electrical insulating liquids. In this paper, we present a comparison of mineral and hydrocarbon oil (liquefied gas) in terms of conductivity and relaxation mechanisms in the complex plane of the Cole-Cole diagram and dielectric losses. We perform the comparison using the method of dielectric relaxation spectroscopy in the frequency domain at different intensities of the time-varying electric field 0.5 kV/m, 5 kV/m, and 50 kV/m. With the increasing intensity of the time-varying electric field, there is a better approximation of the Debye behavior in all captured polarization processes of the investigated oils. By comparing the distribution of relaxation times, mineral oil shows closer characteristics to Debye relaxation. From the point of view of dielectric losses at the main frequency, hydrocarbon oil achieves better dielectric properties at all applied intensities of the time-varying electric field, which is very important for practical use.
Many problems arise in the operation of photovoltaic systems. Each of these problems affects the operation of photovoltaic systems by reducing the power of the entire system. Some problems can be avoided during the design of photovoltaic systems. For example, when designing photovoltaic systems, it is possible to eliminate the shading of photovoltaic panels from surrounding objects. It is also necessary to look at the shading from neighboring photovoltaic panels when designing photovoltaic systems. It is necessary to calculate the inclination of the sunlight based on the position of the sun and calculate the distance between the two panels accordingly. However, some problems appear during the operation of photovoltaic systems. These problems can be partially eliminated. The magnitude of the series resistance can be eliminated by reducing the transition resistance throughout the system. The paper describes these problems and their possible solutions in practice. In the practical part, we focused on simulations and experiments in the field of photovoltaic systems (PV). The simulations focused on both the influence of temperature and the series resistance of photovoltaic panels on the production of electricity. The experiments were focused on the influence of various faults/defects on the power and V-A characteristics of photovoltaic panels connected in strings. The paper also discusses the impact of bypass diodes on the operation of photovoltaic systems and determines the need to use bypass diodes.
1 November 2018 in Journal of Magnetism and Magnetic Materials
This article deals with the prosumer behavior, specifically on an on-grid electrical network that is connected to a larger synchronous electrical network, as well as an off-grid system. In the Simulink (Matlab) application, two models were constructed for this purpose. The modeling of the operation of the electrical network’s on-grid system takes place in one of the models. The simulation of the operation of the electrical network’s off-grid system takes place in the other. We examined the model’s behavior in the provided simulated period from the standpoint of transient states and qualitative indicators of electrical energy under various connection configurations in both systems. The simulations resulted in the possibility of incorporating new sources of energy accumulation, such as pumped storage hydropower plants based on energy storage systems (ESSs), and modifying the model to the user’s needs.
This article deals with the impact of electromagnetic field close to conductors of high voltage poles. The results of this article are based on computer simulation an on-site measuring. The recommendations for persons close to high voltage poles and overhead lines were deduced according to obtained results.
This work aimed to improve how the equipment of a grid-tied solar-wind system used the installed power of the storage battery while reducing the cost of electricity consumed by a local object from the grid. A method for calculating the parameters for a given load schedule is proposed, along with the value of the reduction in electricity consumption. Values for the power generation of a wind generator and photovoltaic battery are based on archival data. The possible power ratio of the wind generator and the photovoltaic battery is 1:8.33. The formation of the state of charge of the battery involves: a calculation of its value for the morning peak according to the forecast for the next day; adjustable discharge in the evening with full or partial compensation for the load consumption according to the forecast for the next day; a night charge with a given current value. At a one-tariff plan, one battery discharge cycle per day is used. A night charge from the grid is not used. With a two-tariff plan and the use of a night battery charge from the grid, one discharge cycle is used in the spring-summer-autumn period. The simulation confirms the possibility of reducing electricity costs by 2.9 times in winter, which corresponds to the set value, alongside a complete elimination of costs in summer.