Samaneh Mostafapour

Samaneh Mostafapour

Auto-generated profile, based on publicly available information

Samaneh Mostafapour

Department of Nuclear Medicine and Molecular Imaging, University Medical Center Groningen, University of Groningen, Groningen, The Netherlands; and

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2023 in Cancers
Verified
Journal Article
Open access
PDF file
MRMostafa Roya
Mostafa Roya
SMSamaneh Mostafapour
Samaneh Mostafapour
PMPhilipp Mohr
Philipp Mohr
LPLaura Providência
Laura Providência
ZLZekai Li
Zekai Li
Joyce van SluisJoyce van Sluis
Joyce van Sluis
The latest technical development in the field of positron emission tomography/computed tomography (PET/CT) imaging has been the extension of the PET axial field-of-view. As a result of the increased number of detectors, the long axial field-of-view (LAFOV) PET systems are not only characterized by a larger anatomical coverage but also by a substantially improved sensitivity, compared with conventional short axial field-of-view PET systems. In clinical practice, this innovation has led to the following optimization: (1) improved overall image quality, (2) decreased duration of PET examinations, (3) decreased amount of radioactivity administered to the patient, or (4) a combination of any of the above. In this review, novel applications of LAFOV PET in oncology are highlighted and future directions are discussed.

13 November 2024 in Seminars in Nuclear Medicine
Verified
Journal Article
Open access
TMT. Samara Martinez-Lucio
T. Samara Martinez-Lucio
OMOscar Isaac Mendoza-Ibañez
Oscar Isaac Mendoza-Ibañez
WLWanling Liu
Wanling Liu
SMSamaneh Mostafapour
Samaneh Mostafapour
ZLZekai Li
Zekai Li
Riemer H.J.A. SlartRiemer H.J.A. Slart
Riemer H.J.A. Slart
Positron emission tomography / computed tomography (PET/CT) plays a pivotal role in the assessment of cardiovascular diseases (CVD), particularly in the context of ischemic heart disease. Nevertheless, its application in other forms of CVD, such as infiltrative, infectious, or inflammatory conditions, remains limited. Recently, PET/CT systems with an extended axial field of view (LAFOV) have been developed, offering greater anatomical coverage and significantly enhanced PET sensitivity. These advancements enable head-to-pelvis imaging with a single bed position, and in systems with an axial field of view (FOV) of approximately 2 meters, even total body (TB) imaging is feasible in a single scan session. The application of LAFOV PET/CT in CVD presents a promising opportunity to improve systemic cardiovascular assessments and address the limitations inherent to conventional short axial field of view (SAFOV) devices. However, several technical challenges, including procedural considerations for LAFOV systems in CVD, complexities in data processing, arterial input function extraction, and artefact management, have not been fully explored. This review aims to discuss the technical aspects of LAFOV PET/CT in relation to CVD by highlighting key opportunities and challenges and examining the impact of these factors on the evaluation of most relevant CVD.

3 October 2025 in Journal of Nuclear Medicine
Verified
Journal Article
Closed access
PDF file
SMSamaneh Mostafapour
Samaneh Mostafapour
JSJoyce van Sluis
Joyce van Sluis
JSJohannes H. van Snick
Johannes H. van Snick
WNWalter Noordzij
Walter Noordzij
GSGilles N. Stormezand
Gilles N. Stormezand
CTCharalampos Tsoumpas
Charalampos Tsoumpas
Recent advances in high-sensitivity PET allow for significantly reduced radiation doses, making the CT radiation dose a larger fraction of the total scan dose. This is the first study to the best of our knowledge that evaluates the feasibility and efficacy of an ultra-low-dose CT (ULD-CT) protocol, incorporating a Sn filter, by reducing radiation exposure while maintaining PET image quality and quantitative accuracy in oncology patients. Methods: The study involved 29 oncology patients. FDG PET/CT scans were performed using both low-dose CT (LD-CT) and ULD-CT protocols. The ULD-CT protocol used the Sn filter with 100 kVp and 6 mAs, whereas the LD-CT protocol, optimized for PET attenuation correction and anatomic localization, was performed without the Sn filter, using 100–120 kVp and 12–30 mAs. Quantitative and qualitative comparisons of PET images were made, focusing on SUVs, Patlak analysis, and diagnostic quality on different tissues. Results: The ULD-CT protocol reduced the CT radiation dose by 97%, from 1.93 ± 0.61 mSv to 0.059 ± 0.026 mSv. SUV comparisons showed relative variations of less than 3%. The net rate of influx values resulting from the Patlak reconstruction showed negligible differences across various tissues between ULD-CT and LD-CT PET reconstructions. Image quality assessments revealed no significant differences between ULD-CT and LD-CT PET reconstructions, with consistently high scores (greater than 4 on a 5-point Likert scale). Lesion detection analysis showed strong intraobserver agreement (intraclass correlation coefficient > 0.85) without significant differences in lesion localization. Conclusion: The ULD-CT protocol substantially reduces radiation exposure in PET/CT while maintaining diagnostic quality of PET scans and introducing negligible quantitative effects, thereby paving the way for optimizing CT radiation protocols in PET/CT imaging. Visual Abstract

8 September 2024
Verified
Conference Paper
Closed access
SMSamaneh Mostafapour
Samaneh Mostafapour
MGMazarine Van der Galiën
Mazarine Van der Galiën
Joyce van SluisJoyce van Sluis
Joyce van Sluis
ABAdrienne Brouwers
Adrienne Brouwers
ZLZekai Li
Zekai Li
CTCharalampos Tsoumpas
Charalampos Tsoumpas
The use of Ultra-Low-Dose computed tomography (ULD-CT) in PET/CT imaging is gaining attention due to its potential to significantly reduce radiation exposure, which is crucial for patient safety. Accurate organ segmentation is essential for treatment planning, particularly in radiotherapy where it aids in delineating target volumes and organs at risk. This study investigated the reproducibility of organ segmentation on ULD-CT in PET/CT imaging. In a cohort of 28 patients undergoing [18F]FDG PET/CT scans, segmentation outcomes were compared between standard low-dose CT (LD-CT) and ULD-CT images. Segmentations were performed using the TotalSegmentator and MOOSE tools, and accuracy was quantified using metrics such as the Dice coefficient, Jaccard index, and Hausdorff and Average distance. Results indicated that ULD-CT, despite its significantly reduced radiation dose and increased image noise, achieved comparable segmentation accuracy to LD-CT for most anatomical structures, with Dice coefficients and Jaccard indices maintaining high values across segmented organs. However, lower reproducibility was observed for structures like the kidneys, and aorta, potentially due to the presence of adjacent structures with similar intensities, making accurate boundary delineation more challenging, especially in the noisy ULD-CT images. Quantitative PET analyses, represented by SUVmean and SUVmax, also showed consistent results between LD-CT and ULD-CT reconstructions. However, the segmentation tools exhibited some errors even on the LD-CT images, that means there are areas for further improvement in these tools. Overall, the study emphasizes that ULD-CT does not compromise the use of automatic segmentation tools like TotaSegmentator and Moose, maintaining the clinical utility of PET/CT scans for most anatomical structures while reducing radiation exposure.

13 February 2025 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
SMSamaneh Mostafapour
Samaneh Mostafapour
JSJoyce van Sluis
Joyce van Sluis
ALAdriaan A. Lammertsma
Adriaan A. Lammertsma
CTCharalampos Tsoumpas
Charalampos Tsoumpas