Ebraahim Afjei

Ebraahim Afjei

Auto-generated profile, based on publicly available information

Ebraahim Afjei

Electrical Engineering Faculty, Shahid Beheshti University, Tehran, Iran

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2019 in Solar Energy
Verified
Journal Article
Closed access
ASAli Sarikhani
Ali Sarikhani
BABabak Allahverdinejad
Babak Allahverdinejad
MHMohsen Hamzeh
Mohsen Hamzeh
EAEbrahim Afjei
Ebrahim Afjei

21 March 2012 in IEEE Transactions on Magnetics
Verified
Journal Article
Closed access
HTHossein Torkaman
Hossein Torkaman
EAEbrahim Afjei
Ebrahim Afjei
PYPeyman Yadegari
Peyman Yadegari
This paper presents a new method for noninvasive diagnosis of static, dynamic, and mixed eccentricity faults in switched reluctance motors (SRMs). This method makes it possible to precisely determine the eccentricity fault features. The proposed signature in this algorithm is based on the analysis of produced current with a particular variation pattern. It is theoretically shown that the occurrence and growth of the fault level cause an increase in amplitude of the produced current signature (PCS), which can be employed to diagnose the fault and extract its details. In this method, first, occurrence of the fault and its location are detected by utilizing eccentricity level detection pattern. Afterward, a new index to precisely determine the fault level is introduced. Then, a novel strategy based on the proposed pattern and index is offered to detect the type of eccentricity as well as the exact location of the faulty phase. For this purpose, an SRM under eccentricity fault is modeled using three dimensional transient finite element method (TFEM). This precise model considers all complex motor geometry, nonlinear characteristics of the motor, end effects and axial fringing effects. A test bed in the laboratory is established to perform various measurements on the eccentric motor with different fault levels. The experimental results validate the numerical analysis outcomes. Fault detection and analysis in SRM demonstrate that the algorithm presented can assure the reliability of detection as well as the sensitivity of eccentricity fault in a SRM.

17 May 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
MHMohsen Hamzeh
Mohsen Hamzeh
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei
In this paper, a simplified equivalent model is proposed to investigate low-frequency (LF) stability of dc microgrids. This is done by using an impedance-based approach considering exact models of microgrid components. In order to apply the impedance-based stability criterion, a multi-bus dc microgrid is first categorized as multiple interconnected single-bus dc microgrids. Then, each single-bus system is classified into two subsystems: subsystem#1 which only includes voltage-controlled (VC) DGs and subsystem#2 which includes the rest of the dc microgrid components. It is shown that due to the absence of LF interaction between subsystems, the dominant LF modes of a single-bus dc microgrid are mainly determined by the droop controllers of VC-DGs. The studies also show that the droop controller of each VC-DG accounts for the LF complex conjugate zeros at the output impedance of each VC-DG; and the internal interaction among these zeros can result in LF poles, which are the origin of LF current/power oscillations in dc microgrids. Through further analyses, it is shown that our findings for single-bus dc microgrids can be extended to any multi-bus dc microgrid as well. Owing to this fact, a simplified equivalent model, which can lead to the order reduction of the overall system, is proposed for the analysis of LF stability of dc microgrids. Thanks to the simplicity and generality of the proposed equivalent model, the effect of different parameters, such as number of VC-DGs, internal voltage controller of VC-DGs, and the microgrid line impedances on the LF stability of dc microgrids is comprehensively investigated. The studies also show that the LF stability of a dc microgrid is approximately independent of droop types (current or power). A complete set of simulation studies are provided which further supports the effectiveness of the proposed model.

31 May 2011 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
HTHossein Torkaman
Hossein Torkaman
EAEbrahim Afjei
Ebrahim Afjei
MTMohammad Sedigh Toulabi
Mohammad Sedigh Toulabi
This paper presents a new configuration for switched reluctance motor (SRM) which can be proposed as a suitable candidate for high-torque and low-flux-leakage SRMs. Unlike the conventional SRMs, this configuration has no direct windings wrapped on the stator poles. This motor consists of three different sets, and each set has one concentric independent winding, two layers of the stator poles, and three layers of the rotor poles in which the middle rotor layer acts as a core for phase winding. To evaluate the motor performance, two types of analysis, namely, numerical technique and experimental study, have been utilized. In the numerical analysis, the 3-D finite-element method is employed, whereas in the experimental study, a prototype motor has been fabricated and tested in the laboratory. Finally, experimental results are compared to conventional SRM to verify the advantages of the proposed motor and show its applicability.

28 April 2017 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
MHMohsen Hamzeh
Mohsen Hamzeh
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei
A comprehensive analysis is carried out to investigate the high-frequency (HF) oscillations and their leading causes in dc microgrids. The analysis relies on the impedance-based stability criterion. It is shown for the first time that all types of DGs and loads contribute to the HF oscillations in a dc microgrid. This is in contrast with the previous studies that designate constant-power loads as the main cause for the interaction dynamics in dc microgrids. It is noted that different factors including number of DGs, load dynamics, load powers, and the type of resonances affecting the HF voltage/current oscillations are taken into account in our studies. A closed-form expression is derived for the estimation of the damping factor of dominant HF modes of dc microgrids. Moreover, a proper damping approach is proposed to reduce the HF oscillations. Various simulation studies are presented to evaluate the effectiveness of the proposed analysis approach.

1 July 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
JKJasem Khajesalehi
Jasem Khajesalehi
KSKeyhan Sheshyekani
Keyhan Sheshyekani
MHMohsen Hamzeh
Mohsen Hamzeh
EAEbrahim Afjei
Ebrahim Afjei
This study presents a high‐performance photovoltaic (PV)‐battery hybrid power conversion system (HPCS) which is integrated to a microgrid using a quasi‐Z‐source inverter (qZSI). The battery system is directly connected to the intermediate dc link of the qZSI without any extra converter which reduces the size and the cost of the power electronic interface. A controller equipped with a harmonic compensator is designed to control the battery current in the grid‐connected mode and to regulate the microgrid voltage in the islanded mode in the presence of unbalanced and non‐linear loads. Furthermore, the proposed controller adjusts the shoot‐through duty cycle of the qZSI to regulate the PV voltage to its reference value provided through the maximum power point tracking algorithm. Moreover, the proposed controller provides the microgrid with the capability to transfer between the two operation modes. A new strategy is adopted to keep the HPCS operational in case of severe reduction in the available power of the PV modules and its consequent voltage drop. The performance of the proposed control system is evaluated for the control of a typical microgrid simulated in MATLAB/SIMULINK environment.