Nasim Rashidirad

Dr. Nasim Rashidirad

Power System Simulation and Evolution, Hydro-Québec, Varennes, Quebec, Canada
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 May 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
MHMohsen Hamzeh
Mohsen Hamzeh
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei
In this paper, a simplified equivalent model is proposed to investigate low-frequency (LF) stability of dc microgrids. This is done by using an impedance-based approach considering exact models of microgrid components. In order to apply the impedance-based stability criterion, a multi-bus dc microgrid is first categorized as multiple interconnected single-bus dc microgrids. Then, each single-bus system is classified into two subsystems: subsystem#1 which only includes voltage-controlled (VC) DGs and subsystem#2 which includes the rest of the dc microgrid components. It is shown that due to the absence of LF interaction between subsystems, the dominant LF modes of a single-bus dc microgrid are mainly determined by the droop controllers of VC-DGs. The studies also show that the droop controller of each VC-DG accounts for the LF complex conjugate zeros at the output impedance of each VC-DG; and the internal interaction among these zeros can result in LF poles, which are the origin of LF current/power oscillations in dc microgrids. Through further analyses, it is shown that our findings for single-bus dc microgrids can be extended to any multi-bus dc microgrid as well. Owing to this fact, a simplified equivalent model, which can lead to the order reduction of the overall system, is proposed for the analysis of LF stability of dc microgrids. Thanks to the simplicity and generality of the proposed equivalent model, the effect of different parameters, such as number of VC-DGs, internal voltage controller of VC-DGs, and the microgrid line impedances on the LF stability of dc microgrids is comprehensively investigated. The studies also show that the LF stability of a dc microgrid is approximately independent of droop types (current or power). A complete set of simulation studies are provided which further supports the effectiveness of the proposed model.

28 April 2017 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Open access
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
MHMohsen Hamzeh
Mohsen Hamzeh
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei
A comprehensive analysis is carried out to investigate the high-frequency (HF) oscillations and their leading causes in dc microgrids. The analysis relies on the impedance-based stability criterion. It is shown for the first time that all types of DGs and loads contribute to the HF oscillations in a dc microgrid. This is in contrast with the previous studies that designate constant-power loads as the main cause for the interaction dynamics in dc microgrids. It is noted that different factors including number of DGs, load dynamics, load powers, and the type of resonances affecting the HF voltage/current oscillations are taken into account in our studies. A closed-form expression is derived for the estimation of the damping factor of dominant HF modes of dc microgrids. Moreover, a proper damping approach is proposed to reduce the HF oscillations. Various simulation studies are presented to evaluate the effectiveness of the proposed analysis approach.

4 May 2017 in IEEE Journal on Emerging and Selected Topics in Circuits and Systems
Verified
Journal Article
Closed access
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
MHMohsen Hamzeh
Mohsen Hamzeh
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei
This paper proposes a new active method for low frequency (LF) current/power oscillations damping in droop-controlled dc microgrids. Since, LF oscillations are mainly affected by droop controllers of voltage controlled (VC) DGs, detailed small-signal analysis of VC-DGs is provided. Analysis shows that each droop-controlled VC-DG creates a pair of LF complex conjugate zeros. In the proposed method, these zeros are damped by a negative feedforward of the disturbance variables (output currents) of VC-DGs. Stability analysis of the overall dc microgrid reveals that the LF zeros of VC-DGs can affect the LF modes of the system. Therefore, in the proposed method, the effective tuning of feedforward gain of each VC-DG can increase the damping factor of microgrid LF modes and consequenctly improve the dynamic response of the whole system. Moreovere, to gurantee the plug-and-play performance of DGs, a coordinanted tuning criterion for adjusting the proper feedforward gains is presented. It is shown that the proposed method is also robust against structural changes in dc microgrids. A complete set of simulation studies using MATLAB/Simulink is provided which further supports the effectiveness of the proposed active damping method.

28 April 2016 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
MHMohsen Hamzeh
Mohsen Hamzeh
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei
A new islanding detection technique is proposed for the application in multiple inverter-based distributed generation (DG) systems. In the proposed method, a harmonic current disturbance is imposed to the grid at one of the harmonic frequencies associated with the grid voltage. This is done by changing the equivalent parallel impedance of the grid-connected inverters. The output current of the grid-connected inverters at this specific harmonic frequency is used as the islanding detection signal. The harmonic resonance is imposed over a short time interval, hence the overall power quality is not significantly affected. As opposed to most of the active islanding detection methods, in the proposed method, no interference among parallel DGs is observed, which makes it well suited for the application in systems involving a large number of parallel inverter-based DGs. Comprehensive analyses are performed to investigate various technical aspects of the proposed scheme. The performance of the proposed method is verified using time-domain simulations carried out in Matlab/Simulink environment.

18 August 2022 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
JMJean Mahseredjian
Jean Mahseredjian
Ilhan KocarIlhan Kocar
Ilhan Kocar
UKUlas Karaagac
Ulas Karaagac
OSOmar Saad
Omar Saad
This paper presents a novel load-flow method for unbalanced islanded ac microgrids. The principles of this method are based on the modified augmented nodal analysis (MANA) formulation. It is shown that it can considerably improve the performance over conventional mismatch equation-based solvers for islanded microgrids, while being more generic and simpler to formulate. An unbalanced 25-bus ac microgrid is used to verify the validity and efficiency of the proposed MANA-based formulation. The results are compared against mismatch formulation to demonstrate better computational speed and reduced number of iterations.

1 October 2017 in Applied Energy
Verified
Journal Article
Closed access
MMMohammad Mahdavyfakhr
Mohammad Mahdavyfakhr
Nasim RashidiradNasim Rashidirad
Nasim Rashidirad
MHMohsen Hamzeh
Mohsen Hamzeh
KSKeyhan Sheshyekani
Keyhan Sheshyekani
EAEbrahim Afjei
Ebrahim Afjei