Henry Ho

Henry Ho

Auto-generated profile, based on publicly available information

Henry Ho

Anderson Orthopedic Research Institute, Alexandria, Virginia

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2024 in The Bone & Joint Journal
Verified
Journal Article
Closed access
PDF file
KFKevin B Fricka
Kevin B Fricka
EWEric J. Wilson
Eric J. Wilson
ASAlexander V. Strait
Alexander V. Strait
HHHenry Ho
Henry Ho
JHJr Robert H. Hopper
Jr Robert H. Hopper
RSRobert A. Sershon
Robert A. Sershon
Aims: The optimal bearing surface design for medial unicompartmental knee arthroplasty (UKA) remains controversial. The aim of this study was to compare outcomes of fixed-bearing (FB) and mobile-bearing (MB) UKAs from a single high-volume institution.Methods: Prospectively collected data were reviewed for all primary cemented medial UKAs performed by seven surgeons from January 2006 to December 2022. A total of 2,999 UKAs were identified, including 2,315 FB and 684 MB cases. The primary outcome measure was implant survival. Secondary outcomes included 90-day and cumulative complications, reoperations, component revisions, conversion arthroplasties, range of motion, and patient-reported outcome measures. Overall mean age at surgery was 65.7 years (32.9 to 94.3), 53.1% (1,593/2,999) of UKAs were implanted in female patients, and demographics between groups were similar (p > 0.05). The mean follow-up for all UKAs was 3.7 years (0.0 to 15.6).Results: Using revision for any reason as an endpoint, five-year survival for FB UKAs was 97.2% (95% CI 96.4 to 98.1) compared to 96.0% for MB (95% CI 94.1 to 97.9; p = 0.008). The FB group experienced fewer component revisions (14/2,315, 0.6% vs 12/684, 1.8%; p < 0.001) and conversion arthroplasties (38/2315, 1.6% vs 24/684, 3.5%; p < 0.001). A greater number of MB UKAs underwent revision due to osteoarthritis progression (FB = 21/2,315, 0.9% vs MB = 16/684, 2.3%; p = 0.003). In the MB group, 12 (1.8%) subjects experienced bearing dislocations which required revision surgery. There were 15 early periprosthetic tibia fractures (0.6%) in the FB group compared to 0 for MB (p = 0.035).Conclusion: In similar patient populations, FB UKAs demonstrated slightly higher survival than a commonly used MB design. Adverse event profiles differed by bearing type, with an increased risk of bearing dislocation and OA progression with MB designs, and early periprosthetic tibia fractures for FB designs.Cite this article: Bone Joint J 2024;106-B(9):916–923.

17 May 2021 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
ESEdwin P. Su
Edwin P. Su
HHHenry Ho
Henry Ho
VBVinay Bhal
Vinay Bhal
LHLawrence R. Housman
Lawrence R. Housman
JMJohn L. Masonis
John L. Masonis
CEC. Anderson Engh
C. Anderson Engh
Background: The BIRMINGHAM HIP Resurfacing (BHR) system is a metal-on-metal hip implant system approved by the U.S. Food and Drug Administration in 2006. The approval required a multicenter, prospective, post-market-approval study. Our purpose is to report the current results at 10 years of follow-up. Methods: Between October 2006 and December 2009, 280 primary BHR procedures were performed at 5 sites. Outcome measures included Kaplan-Meier survivorship, reasons for revision, radiographic component stability and osteolysis, Harris hip scores, and metal levels including cobalt and chromium. The mean age at the time of the procedure was 51.3 ± 7.1 years, 74% (206) of 280 BHRs were implanted in male patients, the mean body mass index was 27.8 ± 4.4 kg/m2, and 95% (265) of 280 hips had a primary diagnosis of osteoarthritis. The mean follow-up among all 280 hips was 9.0 ± 2.5 years. Prior to 10-year follow-up, 20 hips were revised and 5 patients representing 5 hips had died. Among the remaining 255 hips, 218 (85%) met the minimum follow-up of 10 years. Results: The 10-year survival free from all-cause component revision was 92.9% (95% confidence interval [CI], 89.8% to 96.1%) for all hips and 96.0% (95% CI, 93.1% to 98.9%) among male patients <65 years old at the time of the procedure. Reasons for revision included femoral loosening (n = 5), femoral neck fracture (n = 3), pseudotumor (n = 3), osteolysis (n = 2), and acetabular loosening (n = 1), as well as 6 revisions for a combination of pain, noise, or metal levels. Among unrevised hips, the median Harris hip score improved from preoperatively (59) to 1 year postoperatively (99; p < 0.001) and remained stable through 10 years postoperatively (99; p = 0.08). Radiographically, 5% (10) of 218 unrevised hips had osteolysis with no component migration. Median metal levels had increased at 1 year postoperatively (cobalt: from 0.12 ppb preoperatively to 1.5 ppb at 1 year postoperatively, p < 0.001; chromium: from 0.6 ppb preoperatively to 1.7 ppb at 1 year postoperatively, p < 0.001), then remained stable through 5 years before slightly decreasing at 10 years postoperatively (cobalt: 1.3 ppb, p < 0.001; chromium: 1.4 ppb, p < 0.001). Conclusions: This prospective, multicenter, post-market-approval study demonstrated that the BHR implant system is safe and effective through 10 years of follow-up, particularly among young male patients. Level of Evidence: Therapeutic Level IV. See Instructions for Authors for a complete description of levels of evidence.

1 January 1997 in MRS Proceedings
Verified
Journal Article
Closed access
PDF file
DMDimitrios Maroudas
Dimitrios Maroudas
MGM. Rauf Gungor
M. Rauf Gungor
HHHenry S. Ho
Henry S. Ho
MEMatthew N. Enmark
Matthew N. Enmark

1 July 2026 in JBJS Case Connector
Verified
Journal Article
Closed access
JRJacqueline R. Ray
Jacqueline R. Ray
CJChristopher M. Jaicks
Christopher M. Jaicks
HHHenry Ho
Henry Ho
RHRobert H. Hopper
Robert H. Hopper
CMCraig J. McAsey
Craig J. McAsey
Case: A 79-year-old man presented with progressive right thigh pain over 6 months and reliance on a cane. He had undergone primary total hip arthroplasty (THA) with a metal-on-metal bearing in 2007. In 2025, radiographs revealed a fracture of his 18-mm diameter extensively porous-coated, cobalt-chrome alloy femoral stem (Prodigy, DePuy Orthopaedics), prompting revision THA. To the best of our knowledge, this case represents the largest diameter fracture of this type of component reported to date. Conclusion: While fractures of smaller diameter stems are well-documented, clinicians should be aware that fatigue fractures can also occur in very large diameter components with a cylindrical distal geometry.

27 March 2026 in Journal of Orthopaedic Reports
Verified
Journal Article
Open access
NONicholas R. Olson
Nicholas R. Olson
TNTobenna N. Nwankwo
Tobenna N. Nwankwo
JRJacqueline R. Ray
Jacqueline R. Ray
CJChristopher Jaicks
Christopher Jaicks
HHHenry Ho
Henry Ho
RSRobert A. Sershon
Robert A. Sershon