Øyvind Stavdahl

Øyvind Stavdahl

Auto-generated profile, based on publicly available information

Øyvind Stavdahl

Department of Engineering Cybernetics, Norwegian University of Science and Technology, Trondheim, Norway

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2012 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
AFAnders Fougner
Anders Fougner
ØSØyvind Stavdahl
Øyvind Stavdahl
PKPeter J. Kyberd
Peter J. Kyberd
YLYves G. Losier
Yves G. Losier
PPPhilip A. Parker
Philip A. Parker
The recent introduction of novel multifunction hands as well as new control paradigms increase the demand for advanced prosthetic control systems. In this context, an unambiguous terminology and a good understanding of the nature of the control problem is important for efficient research and communication concerning the subject. Thus, one purpose of this paper is to suggest an unambiguous taxonomy, applicable to control systems for upper limb prostheses and also to prostheses in general. A functionally partitioned model of the prosthesis control problem is also presented along with the taxonomy. In the second half of the paper, the suggested taxonomy has been exploited in a comprehensive literature review on proportional myoelectric control of upper limb prostheses. The review revealed that the methods for system training have not matured at the same pace as the novel multifunction prostheses and more advanced intent interpretation methods. Few publications exist regarding the choice of training method and the composition of the training data set. In this context, the notion of outcome measures is essential. By definition, system training involves optimization, and the quality of the results depends heavily on the choice of appropriate optimization criteria. In order to further promote the development of proportional myoelectric control, these topics need to be addressed.

15 August 2011 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
AFAnders Fougner
Anders Fougner
ESErik Scheme
Erik Scheme
ACAdrian D. C. Chan
Adrian D. C. Chan
KEKevin Englehart
Kevin Englehart
ØSØyvind Stavdahl
Øyvind Stavdahl
Reported studies on pattern recognition of electromyograms (EMG) for the control of prosthetic devices traditionally focus on classification accuracy of signals recorded in a laboratory. The difference between the constrained nature in which such data are often collected and the unpredictable nature of prosthetic use is an example of the semantic gap between research findings and a viable clinical implementation. In this paper, we demonstrate that the variations in limb position associated with normal use can have a substantial impact on the robustness of EMG pattern recognition, as illustrated by an in- crease in average classification error from 3.8% to 18%. We propose to solve this problem by: 1) collecting EMG data and training the classifier in multiple limb positions and by 2) measuring the limb position with accelerometers. Applying these two methods to data from ten normally limbed subjects, we reduce the average classification error from 18% to 5.7% and 5.0%, respectively. Our study shows how sensor fusion (using EMG and accelerometers) may be an efficient method to mitigate the effect of limb position and improve classification accuracy.

1 January 2012 in Robotics and Autonomous Systems
Verified
Journal Article
Closed access
PLP. Liljebäck
P. Liljebäck
KPKristin Pettersen
Kristin Pettersen
ØSØ. Stavdahl
Ø. Stavdahl
JGJ.T. Gravdahl
J.T. Gravdahl

1 August 2010
Verified
Conference Paper
Closed access
ESErik Scheme
Erik Scheme
AFA. Fougner
A. Fougner
ØSØ. Stavdahl
Ø. Stavdahl
ACA.D.C. Chan
A.D.C. Chan
KEK. Englehart
K. Englehart
Pattern recognition of myoelectric signals for the control of prosthetic devices has been widely reported and debated. A large portion of the literature focuses on offline classification accuracy of pre-recorded signals. Historically, however, there has been a semantic gap between research findings and a clinically viable implementation. Recently, renewed focus on prosthetics research has pushed the field to provide more clinically relevant outcomes. One way to work towards this goal is to examine the differences between research and clinical results. The constrained nature in which offline training and test data is often collected compared to the dynamic nature of prosthetic use is just one example. In this work, we demonstrate that variations in limb position after training can have a substantial impact on the robustness of myoelectric pattern recognition.

1 September 2014
Verified
Conference Paper
Closed access
PLPal Liljeback
Pal Liljeback
OSOyvind Stavdahl
Oyvind Stavdahl
KPKristin Pettersen
Kristin Pettersen
JGJan Tommy Gravdahl
Jan Tommy Gravdahl
This paper presents the snake robot Mamba, which is a modular, reconfigurable, and waterproof experimental platform developed to support the ongoing research on snake robot locomotion, including underwater locomotion. A novel contribution of the snake robot is its ability to measure environment contact forces acting along its body, which is achieved by isolating the actuator inside each joint module with a custom-designed force/torque sensor. The paper describes the design of this sensor and presents experimental results which illustrate its performance.

18 April 2012 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Closed access
ASAnnette Stahl
Annette Stahl
CSChristian Schellewald
Christian Schellewald
ØSØyvind Stavdahl
Øyvind Stavdahl
OAOle Morten Aamo
Ole Morten Aamo
LALars Adde
Lars Adde
HKHarald Kirkerod
Harald Kirkerod
Cerebral palsy (CP) is a perinatally acquired nonprogressive brain damage resulting in motor impairment affecting mobility and posture. Early identification of infants with CP is desired to target early interventions and follow-up. During early infancy, distinct motion patterns occur which are highly predictive for later disability. These motor patterns can be observed and recorded. In this paper, a method to predict later CP based on early video recordings of the infants' spontaneous movements, applying optical flow and statistical pattern recognition, is presented. We extract motion information from video recordings of young infants using a total variation related optical flow method. By using wavelet analysis features from motion trajectories of points initiated on a regular grid were extracted and classified using a support vector machine.