Katja Glutig

Katja Glutig

Auto-generated profile, based on publicly available information

Katja Glutig

Department of Radiology, Section of Pediatric Radiology, University Hospital, Jena, Germany

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2022 in Molecular and Cellular Pediatrics
Verified
Journal Article
Open access
PDF file
HMHans-Joachim Mentzel
Hans-Joachim Mentzel
KGKatja Glutig
Katja Glutig
SGStephanie Gräger
Stephanie Gräger
PKPaul-Christian Krüger
Paul-Christian Krüger
MWMatthias Waginger
Matthias Waginger
Ultrasound elastography (USE) is a modality that in addition to fundamental B-mode, Doppler, and contrast-enhanced sonography is suitable to make qualitative and quantitative statements about the stiffness of tissues. Introduced more than 20 years ago in adults, USE becomes now a diagnostic tool also in children. The aim of this paper is to describe current available techniques for USE in children. The significance for routine use in children is shown, and further interesting applications are reported.

22 February 2022 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
PKPaul-Christian Krueger
Paul-Christian Krueger
KEKatharina Ebeling
Katharina Ebeling
MWMatthias Waginger
Matthias Waginger
KGKatja Glutig
Katja Glutig
MSMarcel Scheithauer
Marcel Scheithauer
HMHans-Joachim Mentzel
Hans-Joachim Mentzel
Background: Post-processing software can be used in digital radiography to achieve higher image quality, especially in cases of scattered radiation. SimGrid is a grid-like software based on a Convolutional Neuronal Network that estimates the distribution and degree of scattered radiation in radiographs and thus improves image quality by simulating an anti-scatter grid. S-Enhance is an algorithm programmed to improve contrast visibility of foreign material. Objective: The objective of this study was to evaluate the SimGrid and S-Enhance digital radiography post-processing methods for neonatology and paediatric intensive care. Materials and Methods: Two hundred and ten radiographs from the neonatal (n = 101, 0 to 6 months of age) and paediatric (n = 109, 6 months to 18 years of age) intensive care units performed in daily clinical routine using a mobile digital radiography system were post-processed with one of the algorithms, anonymized and then evaluated comparatively by two experienced paediatric radiologists. For every radiograph, patient data and exposure data were collected and analysed. Results: Analysis of different radiographs showed that SimGrid significantly improves image quality for patients with a weight above 10 kg (range: 10–30 kg: odds ratio [OR] = 6.683, P < 0.0001), especially regarding the tracheobronchial system, intestinal gas, and bones. Utilizing S-Enhance significantly advances the assessment of foreign material (OR = 136.111, P < 0.0001) and bones (OR = 34.917, P < 0.0001) for children of all ages and weight, whereas overall image quality decreases. Conclusion: SimGrid offers a differentiated spectrum in image improvement for children beyond the neonatal period whereas S-Enhance especially improves visibility of foreign material and bones for all patients.

21 May 2022 in Abdominal Radiology
Verified
Journal Article
Open access
PDF file
KGKatja Glutig
Katja Glutig
PKPaul-Christian Krüger
Paul-Christian Krüger
TOTheresa Oberreuther
Theresa Oberreuther
MNMarcel Dominik Nickel
Marcel Dominik Nickel
UTUlf Teichgräber
Ulf Teichgräber
MKMartin Krämer
Martin Krämer
Objectives: The aim of this prospective study was to compare scan time, image quality, signal-to-noise Ratio (SNR), and apparent diffusion coefficient (ADC) values of simultaneous multi-slice accelerated diffusion-weighted imaging with motion-correction (DWI SMS Moco) to standard diffusion-weighted imaging (sDWI) in free-breathing abdominal magnetic resonance imaging (MRI) in pediatric and young adult patients with cystic fibrosis (CF). Material and methods: 16 patients (7 male and 9 female, 12–41 years old) with CF were examined prospectively in a single-center from November 2020 to March 2021 on a 1.5 Tesla clinical MR scanner. The characteristics of overall image quality and delimitability of mesenteric lymph nodes were evaluated using a 5-point Likert scale by two experienced pediatric radiologists independently from each other. Quantitative parameters with SNR and ADC values were assessed in 8 different locations and compared using a Wilcoxon signed-rank test. Results: The acquisition time for DWI SMS Moco was 32% shorter than for sDWI. Regarding quality comparison, overall image quality and delimitability of mesenteric lymph nodes were significant higher in DWI SMS Moco (p ≤ 0.05 for both readers). The readers preferred DWI SMS Moco to sDWI in all cases (16/16). Mean SNR values from DWI SMS Moco and sDWI were similar in 7 from 8 locations. The ADC values showed no significant difference between DWI SMS Moco and sDWI in any of the evaluated locations (p > 0.05). Conclusions: The DWI SMS Moco improves overall image quality and delimitability of mesenteric lymph nodes compared to sDWI with similar SNR and ADC values and a distinguished reduction of scan time in free-breathing by one third. We conclude that MRI with DWI SMS Moco could be helpful in monitoring the effect of the high-efficiency modulator (HEM) therapy in cystic fibrosis (CF) patients homozygous or heterozygous for F508del in the abdomen.

12 March 2025 in Respiratory Medicine
Verified
Journal Article
Open access
SGStephanie Gräger
Stephanie Gräger
MPMarkus Puschmann
Markus Puschmann
MLMichael Lorenz
Michael Lorenz
MKMartin Krämer
Martin Krämer
HMHans-Joachim Mentzel
Hans-Joachim Mentzel
KGKatja Glutig
Katja Glutig
Lung ultrasound is becoming increasingly important in the diagnosis of acute and chronic lung disease, especially in children and adolescents. In children with cystic fibrosis (CF), conventional radiography or computed tomography (CT) has been the main modality used to evaluate acute pneumonia or the progression of chronic lung disease. This Study aimed to evaluate Lung-Ultrasound as a diagnostic tool for children and adolescents with CF. We examined 30 CF patients with lung ultrasound before and after spirometry and compared them with lung ultrasounds of 15 lung-healthy children. We used a comprehensive and complete examination procedure with 12 probe positions to determine the best examination procedure in retrospect. In addition, an acceptance survey was conducted among the children and adolescents after the examination. There was a significant difference in pleural irregularities, B-lines, consolidations and the adapted Peixoto et al. score between CF patients and healthy children before spirometry. We found excellent discrimination between patients and lung-healthy subjects using the Peixoto-score (AUC 0.968), pleural irregularities (AUC 0.890. CF patients had more B-lines, more consolidations, and a higher Peixoto score (mean difference 7.7 points).There was no significant difference in lung ultrasound results in children with CF before and after spirometry. Shortening our extended examination procedure would minimally compromise diagnostic accuracy. The lung ultrasound examination was well accepted by the children. We could demonstrate that lung ultrasound is a sensitive and reliable method for assessing pulmonary changes in cystic fibrosis.

15 March 2023 in Pediatric Radiology
Verified
Journal Article
Open access
PDF file
PKPaul-Christian Krueger
Paul-Christian Krueger
MKMartin Krämer
Martin Krämer
TBThomas Benkert
Thomas Benkert
SESophia Ertel
Sophia Ertel
UTUlf Teichgräber
Ulf Teichgräber
KGKatja Glutig
Katja Glutig
Background: Whole-body magnetic resonance imaging (WB-MRI) is an increasingly used guideline-based imaging modality for oncological and non-oncological pathologies during childhood and adolescence. While diffusion-weighted imaging (DWI), a part of WB-MRI, enhances image interpretation and improves sensitivity, it also requires the longest acquisition time during a typical WB-MRI scan protocol. Interleaved short tau inversion recovery (STIR) DWI with simultaneous multi-slice (SMS) acquisition is an effective way to speed up examinations. Objective: In this study of children and adolescents, we compared the acquisition time, image quality, signal-to-noise ratio (SNR) and apparent diffusion coefficient (ADC) values of an interleaved STIR SMS-DWI sequence with a standard non-accelerated DWI sequence for WB-MRI. Materials and methods: Twenty children and adolescents (mean age: 13.9 years) who received two WB-MRI scans at a maximum interval of 18 months, consisting of either standard DWI or SMS-DWI MRI, respectively, were included. For quantitative evaluation, the signal-to-noise ratio (SNR) was determined for b800 images and ADC maps of seven anatomical regions. Image quality evaluation was independently performed by two experienced paediatric radiologists using a 5-point Likert scale. The measurement time per slice stack, pause between measurements including shim and total measurement time of DWI for standard DWI and SMS-DWI were extracted directly from the scan data. Results: When including the shim duration, the acquisition time for SMS-DWI was 43% faster than for standard DWI. Qualitatively, the scores of SMS-DWI were higher in six locations in the b800 images and four locations in the ADC maps. There was substantial agreement between both readers, with a Cohen’s kappa of 0.75. Quantitatively, the SNR in the b800 images and the ADC maps did not differ significantly from one another. Conclusion: Whole body-MRI with SMS-DWI provided equivalent image quality and reduced the acquisition time almost by half compared to the standard WB-DWI protocol.

1 October 2020 in Der Radiologe
Verified
Journal Article
Closed access
PDF file
KGKatja Glutig
Katja Glutig
HMHans-Joachim Mentzel
Hans-Joachim Mentzel