Pooling data from thigh-worn accelerometers across multiple studies has great potential to advance evidence on the health benefits of physical activity. This requires harmonization of information on body postures, physical activity types, volumes and time patterns across different brands of devices. The aim of this study is to compare the physical behavior estimates provided by three different brands of thigh-worn accelerometers. Twenty participants volunteered for a 7-day free-living measurement. Three accelerometers - ActiGraph GT3X+, Axivity AX3 and ActivPAL Micro4 - were randomly placed in a vertical line on the midsection of the right thigh. Raw data from each accelerometer was processed and classified into 8 physical activities and postures using the Acti4 software. Absolute differences between estimates and the respective coefficient of variation (CV) were calculated. We observed very minor differences between physical behavior estimates from three different accelerometer brands. When averaged over 24 h (1,440 min), the absolute difference (CV) between accelerometers were: 1.2 mins (0.001) for lying/sitting, 3.4 mins (0.02) for standing, 3.5 mins (0.06) for moving, 1.9 mins (0.03) for walking, 0.1 mins (0.19) for running, 1.2 mins (0.19) for stair climbing, 1.9 mins (0.07) for cycling. Moreover, there was an average absolute difference of 282 steps (0.03) per 24 h. Physical behaviors were classified with negligible difference between the accelerometer brands. These results support harmonization of data from different thigh-worn accelerometers across multiple cohorts when analyzed in an identical manner.
6 October 2020 in International Journal of Behavioral Nutrition and Physical Activity
Background: Researchers applying compositional data analysis to time-use data (e.g., time spent in physical behaviors) often face the problem of zeros, that is, recordings of zero time spent in any of the studied behaviors. Zeros hinder the application of compositional data analysis because the analysis is based on log-ratios. One way to overcome this challenge is to replace the zeros with sensible small values. The aim of this study was to compare the performance of three existing replacement methods used within physical behavior time-use epidemiology: simple replacement, multiplicative replacement, and log-ratio expectation-maximization (lrEM) algorithm. Moreover, we assessed the consequence of choosing replacement values higher than the lowest observed value for a given behavior.Method: Using a complete dataset based on accelerometer data from 1310 Danish adults as reference, multiple datasets were simulated across six scenarios of zeros (5–30% zeros in 5% increments). Moreover, four examples were produced based on real data, in which, 10 and 20% zeros were imposed and replaced using a replacement value of 0.5 min, 65% of the observation threshold, or an estimated value below the observation threshold. For the simulation study and the examples, the zeros were replaced using the three replacement methods and the degree of distortion introduced was assessed by comparison with the complete dataset.Results: The lrEM method outperformed the other replacement methods as it had the smallest influence on the structure of relative variation of the datasets. Both the simple and multiplicative replacements introduced higher distortion, particularly in scenarios with more than 10% zeros; although the latter, like the lrEM, does preserve the ratios between behaviors with no zeros. The examples revealed that replacing zeros with a value higher than the observation threshold severely affected the structure of relative variation.Conclusions: Given our findings, we encourage the use of replacement methods that preserve the relative structure of physical behavior data, as achieved by the multiplicative and lrEM replacements, andto avoidsimple replacement. Moreover, we do not recommend replacing zeros with values higher than the lowest observed value for a behavior.
The aim of this study was to examine the effects of walking at different speeds while using a mobile phone on spatiotemporal stride parameters among young adults. Ten participants (7 male, 3 female; age = 24.7 ± 4.4 years, mean ± 1SD) completed 12 walking trials. Trials consisted of tasks performed at both normal and fast walking speeds—walking only, walking while texting, and walking while talking on a mobile phone. Gait velocity, stride length, cadence, and double support time were computed using data from accelerometers on either shoe. The effects of distracted walking were not significantly larger when performed at a self-selected fast walking speed compared with a normal walking speed. However, walking while texting produced significant decreases in gait velocity, stride length, and cadence, with a significant increase in double support time at both walking speeds. Moreover texting increased the size of the relative variability of walking, observed through a significant increase in the coefficient of variation of cadence, stride length, and double support time. The observed changes may be suggestive of compromised balance when walking while texting regardless of walking speed. This may place the individual at a greater risk of, slips, trips and falls.
Summary: Accelerometers placed on the thigh provide accurate measures of daily physical activity types, postures and sedentary behaviours, over 24 h and across consecutive days. However, the ability to estimate sleep duration or quality from thigh‐worn accelerometers is uncertain and has not been evaluated in comparison with the ‘gold‐standard’ measurement of sleep polysomnography. This study aimed to develop an algorithm for sleep estimation using the raw data from a thigh‐worn accelerometer and to evaluate it in comparison with polysomnography. The algorithm was developed and optimised on a dataset consisting of 23 single‐night polysomnography recordings, collected in a laboratory, from 15 asymptomatic adults. This optimised algorithm was then applied to a separate evaluation dataset, in which, 71 adult males (mean [SD] age 57 [11] years, height 181 [6] cm, weight 82 [13] kg) wore ambulatory polysomnography equipment and a thigh‐worn accelerometer, simultaneously, whilst sleeping at home. Compared with polysomnography, the algorithm had a sensitivity of 0.84 and a specificity of 0.55 when estimating sleep periods. Sleep intervals were underestimated by 21 min (130 min, Limits of Agreement Range [LoAR]). Total sleep time was underestimated by 32 min (233 min LoAR). Our results evaluate the performance of a new algorithm for estimating sleep and outline the limitations. Based on these results, we conclude that a single device can provide estimates of the sleep interval and total sleep time with sufficient accuracy for the measurement of daily physical activity, sedentary behaviour, and sleep, on a group level in free‐living settings.
Walking while using a mobile phone has been shown to affect the walking dynamics of young adults. However, this has only been investigated using treadmill walking at a fixed walking speed. In this study, the dynamics of over ground walking were investigated using lower trunk acceleration measured over 12 consecutive trials, following differing walking speed and mobile phone use instructions. Higher walking speed significantly increased the proportion of acceleration along the vertical measurement axis, while decreasing the proportion of acceleration along the anteroposterior axis (p < 0.001). Moreover, higher walking speed also resulted in increased sample entropy along all measurement axes (p < 0.05). When walking while texting, the maximum Lyapunov exponent increased along the anteroposterior and vertical measurement axes (p < 0.05), while sample entropy decreased significantly along the vertical axis (p < 0.001). Walking speed and mobile phone use both affect the walking dynamics of young adults. Walking while texting appears to produce a reduction in local dynamic stability and an increase in regularity, however, caution is required when interpreting the extent of this task effect, since walking speed also affected walking dynamics.
16 February 2001 in The Journal of Organic Chemistry