Holger Kryk

Holger Kryk

Auto-generated profile, based on publicly available information

Holger Kryk

Helmholtz-Zentrum Dresden-Rossendorf, Institute of Fluid Dynamics, Bautzner Landstraße 400, Dresden 01328, Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2026 in Chemical Engineering Journal Advances
Verified
Journal Article
Open access
AKAmit Kumar
Amit Kumar
AGAnett Georgi
Anett Georgi
YAYsabel Huaccallo Aguilar
Ysabel Huaccallo Aguilar
MMMarkus Meier
Markus Meier
HKHolger Kryk
Holger Kryk
UHUwe Hampel
Uwe Hampel

19 November 2025 in Energy Conversion and Management
Verified
Journal Article
Open access
TWTom Wenzel
Tom Wenzel
SFStefan Fogel
Stefan Fogel
HKHolger Kryk
Holger Kryk
UHUwe Hampel
Uwe Hampel

22 March 2025 in Journal of Chromatography A
Verified
Journal Article
Open access
TWThomas Willms
Thomas Willms
HKHolger Kryk
Holger Kryk
UHUwe Hampel
Uwe Hampel
In the present work, an improved GC/MS method for the analysis of the reaction products of the non-catalytic partial oxidation of isobutane at a starting temperature of 25°C has been developed and compared to a previously published method [1]. Two green GC-solvents (dimethyl carbonate (DMC), diethyl carbonate (DEC)) and several internal standards (hexane, benzene, toluene, DEC) have been tested. The separation of the products at low retention times (methanol, isobutane, isobutene) could be significantly improved. For the liquid main products t-butyl hydroperoxide (TBHP), di-t-butyl peroxide (DTBP), t-butanol (TBA), propanone and most trace products (isopropanol, isobutanal, methyl formate, isopropyl formate, t-butyl formate and some acetates - 24 compounds in total), a coefficient of determination CoD > 0.999 has been achieved. For all weighing and GC/MS measurements uncertainties have been calculated. The peaks of the peak pair t-butyl formate (CoD >0.999) and isobutanol (CoD >0.99), have been simulated and used for calibrations. DEC gave a decomposition of TBHP on the column. With DMC, a problem of peak purity of TBHP appeared but could be resolved. The use of the green solvent DMC, compared to also studied traditional solvents like heptane and toluene, proved to be very beneficial, since it also permitted to determine polar compounds, e. g. carbon dioxide and formic acid.


26 May 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
TWThomas Willms
Thomas Willms
HKHolger Kryk
Holger Kryk
UHUwe Hampel
Uwe Hampel
The kinetics of the decomposition of undiluted, pure di-tert-butyl peroxide (DTBP) has been investigated by dynamic differential scanning calorimetry (DSC) in HP steel crucibles, using the non-model-based methods of Ozawa, Kissinger, Kissinger-Akahira-Sunrose (KAS), Flynn-Wall-Ozawa-(FWO), Friedman, Vyazovkin and ASTM E698, and model-based approaches. The KAS and FWO method gave no useful kinetic activation parameters, the Friedman and Kissinger method resulted in simulated curves giving a satisfactory description of the experimental DSC curves. The best simulations were obtained by the Friedman method and the model-based method. Among all published kinetic results for the decomposition of pure DTBP by DSC published yet, only one was correspon­ding to the standard of ICTAC. Confirming the activation parameters of the corresponding work in this work, chemically meaningful activation parameters have been identified to be ln(A) = 31.8, EA = 140.0 kJ/ mol with k(164°C) = 1.21E-3 ±7E-8 s-1 obtained by a model-based overall evaluation of four DSC curves by modern software in this work.

6 June 2026 in Energy Conversion and Management
Verified
Journal Article
Open access
TWTom Wenzel
Tom Wenzel
HKHolger Kryk
Holger Kryk
Sebastian Felix ReineckeSebastian Felix Reinecke
Sebastian Felix Reinecke
UHUwe Hampel
Uwe Hampel
SFStefan Fogel
Stefan Fogel