Christine Droigk

Christine Droigk

Auto-generated profile, based on publicly available information

Christine Droigk

University of Luebeck

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2024 in IEEE Transactions on Computational Imaging
Verified
Journal Article
Open access
MMMarco Maass
Marco Maass
TKTobias Kluth
Tobias Kluth
CDChristine Droigk
Christine Droigk
HAHannes Albers
Hannes Albers
KSKonrad Scheffler
Konrad Scheffler
TKTobias Knopp
Tobias Knopp
Magnetic particle imaging is a tracer-based tomographic imaging technique that allows the concentration of magnetic nanoparticles to be determined with high spatio-temporal resolution. To reconstruct an image of the tracer concentration, the magnetization dynamics of the particles must be accurately modeled. A popular ensemble model is based on solving the Fokker-Plank equation, taking into account either Brownian or Néel dynamics. The disadvantage of this model is that it is computationally expensive due to an underlying stiff differential equation. A simplified model is the equilibrium model, which can be evaluated directly but in most relevant cases it suffers from a non-negligible modeling error. In the present work, we investigate an extended version of the equilibrium model that can account for particle anisotropy. We show that this model can be expressed as a series of Bessel functions, which can be truncated based on a predefined accuracy, leading to very short computation times, which are about three orders of magnitude lower than equivalent Fokker-Planck computation times. We investigate the accuracy of the model for 2D Lissajous magnetic particle imaging sequences and show that the difference between the Fokker-Planck and the equilibrium model with anisotropy is sufficiently small so that the latter model can be used for image reconstruction on experimental data with only marginal loss of image quality, even compared to a system matrix-based reconstruction.

16 February 2022 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CDChristine Droigk
Christine Droigk
MMMarco Maass
Marco Maass
AMAlfred Mertins
Alfred Mertins
Magnetic Particle Imaging is a tomographic imaging technique that measures the voltage induced due to magnetization changes of magnetic nanoparticle distributions. The relationship between the received signal and the distribution of the nanoparticels is described by the system function. A common method for image reconstruction is using a measured system function to create a system matrix and set up a regularized linear system of equations. Since the measurement of the system matrix is time-consuming, different methods for acceleration have been proposed. These include modeling the system matrix or using a direct reconstruction method in time, known as X-space reconstruction. In this work, based on the simplified Langevin model of paramagnetism and certain approximations, a direct reconstruction technique for Magnetic Particle Imaging in the frequency domain with two- and three-dimensional Lissajous trajectory excitation is presented. The approach uses Chebyshev polynomials of second kind. During reconstruction, they are weighted with the frequency components of the voltage signal and additional factors and then summed up. To obtain the final nanoparticle distribution, this result is rescaled and deconvolved. It is shown that the approach works for both simulated data and real measurements. The obtained image quality is comparable to a modeled system matrix approach using the same simplified physical assumptions and no relaxation effects. The reconstruction of a 31 × 31 × 31 volume takes less than a second and is up to 25 times faster than the state-of-the-art Kaczmarz reconstruction. Besides, the derivation of the proposed method shows some new theoretical aspects of the system function and its well-known observed similarity to tensor products of Chebyshev polynomials of second kind.

7 February 2019
Verified
Book Chapter
Closed access
PDF file
CDChristine Droigk
Christine Droigk
MMMarco Maass
Marco Maass
CECorbinian Englisch
Corbinian Englisch
AMAlfred Mertins
Alfred Mertins

15 October 2019 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
CDChristine Droigk
Christine Droigk
MMMarco Maass
Marco Maass
AMAlfred Mertins
Alfred Mertins

15 October 2026 in Physics in Medicine & Biology
Verified
Journal Article
Open access
CDChristine Droigk
Christine Droigk
DDDaniel Hernández Durán
Daniel Hernández Durán
MMMarco Maass
Marco Maass
TKTobias Knopp
Tobias Knopp
KSKonrad Scheffler
Konrad Scheffler
Objective. Magnetic particle imaging (MPI) is a tomographic imaging modality capable of real-time, high-sensitivity mapping of superparamagnetic iron oxide nanoparticles. Model-based image reconstruction provides an alternative to conventional methods that rely on a measured system matrix, eliminating the need for laborious calibration measurements. Nevertheless, model-based approaches must account for the complexities of the imaging chain to maintain high image quality. This work investigates and accelerates an adapted direct Chebyshev reconstruction (DCR) method that accounts for the physical effect of magnetic nanoparticle anisotropy. Approach. The adapted DCR method employs weighted Chebyshev polynomials in the frequency domain and incorporates a spatially variant deconvolution step to compensate for magnetic anisotropy effects. The method is evaluated on five experimental phantoms and compared with model-based and measured system matrix reconstructions. In addition, an efficient approximation of the spatially variant deconvolution is introduced to reduce computational runtime and memory consumption while maintaining reconstruction accuracy. The proposed approach is further investigated on simulated three-dimensional data to assess its scalability to volumetric MPI. Main results. The adapted DCR method significantly improves reconstruction quality in real measurements and achieves image fidelity comparable to that of the measured system matrix reconstruction and superior to that of the model-based system matrix reconstruction. The proposed approximation of the spatially variant deconvolution preserves the reconstruction accuracy while reducing computational and memory requirements. Its computational complexity is reduced to O ( N log ⁡ N ) . The method also successfully reconstructs simulated 3D data, demonstrating its applicability to volumetric MPI. Significance. The results demonstrate the potential of the adapted DCR approach to improve model-based MPI reconstruction while avoiding the need for a system matrix. The efficient deconvolution approximation makes the method particularly attractive for high-resolution and three-dimensional imaging by substantially improving its computational efficiency and scalability.