1 May 2017 in The Journal of the Acoustical Society of America
Closed-room scenarios are characterized by reverberation, which decreases the performance of applications such as hands-free teleconferencing and multichannel sound reproduction. However, exact knowledge of the sound field inside a volume of interest enables the compensation of room effects and allows for a performance improvement within a wide range of applications. The sampling of sound fields involves the measurement of spatially dependent room impulse responses, where the Nyquist-Shannon sampling theorem applies in the temporal and spatial domains. The spatial measurement often requires a huge number of sampling points and entails other difficulties, such as the need for exact calibration of a large number of microphones. In this paper, a method for measuring sound fields using moving microphones is presented. The number of microphones is customizable, allowing for a tradeoff between hardware effort and measurement time. The goal is to reconstruct room impulse responses on a regular grid from data acquired with microphones between grid positions, in general. For this, the sound field at equidistant positions is related to the measurements taken along the microphone trajectories via spatial interpolation. The benefits of using perfect sequences for excitation, a multigrid recovery, and the prospects for reconstruction by compressed sensing are presented.
1 November 2024 in IEEE Transactions on Computational Imaging
Magnetic particle imaging is a tracer-based tomographic imaging technique that allows the concentration of magnetic nanoparticles to be determined with high spatio-temporal resolution. To reconstruct an image of the tracer concentration, the magnetization dynamics of the particles must be accurately modeled. A popular ensemble model is based on solving the Fokker-Plank equation, taking into account either Brownian or Néel dynamics. The disadvantage of this model is that it is computationally expensive due to an underlying stiff differential equation. A simplified model is the equilibrium model, which can be evaluated directly but in most relevant cases it suffers from a non-negligible modeling error. In the present work, we investigate an extended version of the equilibrium model that can account for particle anisotropy. We show that this model can be expressed as a series of Bessel functions, which can be truncated based on a predefined accuracy, leading to very short computation times, which are about three orders of magnitude lower than equivalent Fokker-Planck computation times. We investigate the accuracy of the model for 2D Lissajous magnetic particle imaging sequences and show that the difference between the Fokker-Planck and the equilibrium model with anisotropy is sufficiently small so that the latter model can be used for image reconstruction on experimental data with only marginal loss of image quality, even compared to a system matrix-based reconstruction.
16 February 2022 in Physics in Medicine & Biology
Magnetic Particle Imaging is a tomographic imaging technique that measures the voltage induced due to magnetization changes of magnetic nanoparticle distributions. The relationship between the received signal and the distribution of the nanoparticels is described by the system function. A common method for image reconstruction is using a measured system function to create a system matrix and set up a regularized linear system of equations. Since the measurement of the system matrix is time-consuming, different methods for acceleration have been proposed. These include modeling the system matrix or using a direct reconstruction method in time, known as X-space reconstruction. In this work, based on the simplified Langevin model of paramagnetism and certain approximations, a direct reconstruction technique for Magnetic Particle Imaging in the frequency domain with two- and three-dimensional Lissajous trajectory excitation is presented. The approach uses Chebyshev polynomials of second kind. During reconstruction, they are weighted with the frequency components of the voltage signal and additional factors and then summed up. To obtain the final nanoparticle distribution, this result is rescaled and deconvolved. It is shown that the approach works for both simulated data and real measurements. The obtained image quality is comparable to a modeled system matrix approach using the same simplified physical assumptions and no relaxation effects. The reconstruction of a 31 × 31 × 31 volume takes less than a second and is up to 25 times faster than the state-of-the-art Kaczmarz reconstruction. Besides, the derivation of the proposed method shows some new theoretical aspects of the system function and its well-known observed similarity to tensor products of Chebyshev polynomials of second kind.
6 September 2023 in Klinische Padiatrie
NKNiclas Knottnerus-Meyer
Introduction New non-medical monitors are offered for respiration monitoring of neonates. Epigastric motion during sleep was investigated by means of a wearable tracker in parallel to clinical monitoring. Cohort: 23 hospitalised neonates ready for discharge. Methods A 3-axes-accelerometer and -gyroscope was placed in a standard epigastric position. Between two routine care rounds signals were recorded in parallel to monitoring of impedance pneumography (IP), ECG and pulse oximetry. Motion signals vs. time charts were evaluated using 10-min episodes and semiquantitatively assigned to breathing signal quality, regular breathing, periodic breathing and confounding artefacts. The results were compared with the impedance pneumographic data. Results 26 recordings (mean duration: 210 min/infant) were conducted without bradycardia or apnea alarm. The gestational age at birth ranged 28.9 to 41.1 and at recording from 35.6 to 42.3 postmenstrual weeks. Motion patterns of quiet sleep with regular breathing, periodic breathing and active sleep with confounding body movements were found. The longitudinal and transversal gyroscope axes resulted in best signal quality. Periodic breathing was found in up to 80% of episodes and decreased inversely with gestational age showing significantly more periodic breathing in preterm infants. Respiration signals of the gyroscope vs. IP showed a low bias and highly variating frequencies. Conclusions Standardized motion trackers may detect typical neonatal breathing and body-motion-patterns, that could help to classify neonatal sleep. Respiratory rates can only be determined during quiet sleep.
15 October 2019 in International Journal of Computer Assisted Radiology and Surgery