1 January 2011 in Biomedical Engineering / Biomedizinische Technik
Animal studies are an essential method to evaluate implants for the middle ear prior to clinical studies. New Zealand rabbits, guinea pigs and chinchillas are, among other small mammals, well established animal models, but their auditory system is significantly smaller compared to human. Hence, the suitability of the domestic pig (sus scrofa domesticus) as a new animal model for research on the middle ear (ME), that would match the human in size, was investigated. Thirty halved pig heads were obtained from the butcher and each middle ear was dissected. Using a digital light microscope, several anatomical magnitudes were determined for 24 specimens, namely the planar projected area of the tympanic membrane (TM), in relation to the stapes footplate as well as the dimensions and weight of the ossicles, in order to determine the effective lever ratios. Using normal and micro computed tomography (CT), six porcine temporal bones were scanned and the geometric data obtained were transferred into a finite element model (FEM) simulation of the porcine middle ear. The transfer function was determined and compared to those from humans determined by measurements and simulations, respectively. The anatomy investigated presented itself as highly comparable to that of the human. Differing from literature, no fourth ossicle could be found. The porcine dimensions and lever ratios determined match the humans far better than those of all established animal models. The obtained transfer function was congruent to the human one. This underlines the suitability of the pig as an animal model for middle ear implants.
14 February 2019 in Production Engineering
The importance of hybrid composites is increasing, particularly with regard to structural lightweight construction. Therefore, a joining process for the production of hybrid bonds using induction technology is examined in this paper. An appropriate test rig was developed, assembled, commissioned and characterized for this purpose. Heating tests with titanium Ti6Al4V were carried out with this device to determine the influence of the process parameters on the temperature level and the temperature field. This applies in particular to the feed rate, the sample geometry, the relative positioning between sample and inductor as well as to the inductor setting like induction frequency and pulse width modulation. Based on the results of these examinations, a two-stage heating process was developed, which allows the formation of a homogeneous temperature field in the range of the melting and degradation temperature of the used polymer (PPS; Ten-Cate Cetex TC1100) and thus to achieve optimized bond strengths. More specifically, a short phase with a high energy input was used for quick and intensive warming and a longer time period was deployed to reach an even distribution of temperature. Subsequently, joints with CFRP were produced with a specimen geometry suitable for tensile shear tests according to DIN EN 1465 (Adhesives—determination of tensile lap-shear strength of bonded assemblies; German version EN 1465:2009, 2009). The analysis of the tensile shear strength and the fractured surfaces shows that the metal is much more difficult to heat up due to the melting enthalpy of the plastic than preliminary tests indicated. Further tests were carried out, which revealed a threshold value for heating where the temperature was sufficiently high to achieve a complete coating of the plastic on the metal can be achieved. In summary, the investigations showed that the presented method as well as the design of the test rig is generally suitable for bonding metal to thermoplastic polymers. The influence of various parameters on heating and bond strength could be identified. Moreover a process has been established, which allows industrially useful bonding forces. This not only proves that further investigations are useful, but also laid the foundation for further experiments.
9 September 2014 in Physics Procedia
Modern laser beam sources provide radiation with high output power and brilliance. Additionally, innovative laser system technology enables the deflection of the laser into every direction. These developments depict new aspects in laser safety. On the one hand, there is no standard design approach for laser safety barriers and, on the other hand, no practical database of resulting protection times is available. A prototype test rig was built up, which allows the determinationof the protection time of different passive safety barriers. By experimental investigations, a process model for single steel sheets was established, which provides a relation between the applied process parameters and the protection time of the safety barrier. Within the conducted investigations, the laser power and the spot diameter were varied, whereas former investigations only considered the total laser intensity. The presented results show the influence of the varied parameters on the protection time and provide a first database, which will be extended within further investigations.
16 September 2016 in Physics Procedia
Modern laser systems are widely used in industry due to their excellent flexibility and high beam intensities. This leads to an increased hazard potential, because conventional laser safety barriers only offer a short protection time when illuminated with high laser powers. For that reason active systems are used more and more to prevent accidents with laser machines. These systems must fulfil the requirements of functional safety, e.g. according to IEC 61508, which causes high costs. The safety provided by common passive barriers is usually unconsidered in this context. In the presented approach, active and passive systems are evaluated from a holistic perspective. To assess the functional safety of hybrid safety systems, the failure probability of passive barriers is analysed and added to the failure probability of the active system.
16 November 2016 in MM Science Journal