Jiayun Liu

Jiayun Liu

Auto-generated profile, based on publicly available information

Jiayun Liu

State Key Laboratory of High-Efficiency and High-Quality Conversion for Electric Power, Hunan University, Changsha, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 September 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
NMNan Mo
Nan Mo
JHJiayu Hu
Jiayu Hu
QXQianming Xu
Qianming Xu
PGPeng Guo
Peng Guo
JLJiayun Liu
Jiayun Liu
ALAn Luo
An Luo
In the dual active bridge-based single-stage (DAB-1S) ac–dc converter, the varying input power causes a variation in the phase shift ratios, resulting in varying initial current and the generation of dc-bias current (DCBC). The DCBC will aggravate current stress and increase conduction loss, etc. This article introduces an initial current control method of DAB-1S ac–dc converter to eliminate the DCBC. The introduction of control degrees of freedom that are independent of power control enables the initial current of each switching cycle to be controlled to zero in any modulation mode. In this manner, the currents of neighboring switching cycles are decoupled, thereby eliminating the DCBC. Moreover, the impact of nonideal parameters in practical DAB 1S ac–dc converters is analyzed, and corresponding compensation methods are proposed. Meanwhile, mathematical analysis of the switching cycles and grid cycles indicates that this method only changes the initial phase angle of the voltage and current for each switching cycle, leaving the harmonic content of the port current unchanged and the total harmonic distortion of the grid current unaffected. The experimental prototype has confirmed the effectiveness of the dc bias elimination method. Comparative experimentation with various other existing modulation methods highlights the superiority of this method.

1 July 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJiayun Liu
Jiayun Liu
QXQianming Xu
Qianming Xu
JHJiayu Hu
Jiayu Hu
CTCheng Tang
Cheng Tang
PGPeng Guo
Peng Guo
ALAn Luo
An Luo
The capacitor voltage balancing is crucial for the reliable operation of three-level dual-active-bridge (DAB) converters. In contrast to previous balancing control methods, this letter proposes a capacitor voltage self-balancing modulation method by introducing an improved switching sequence (ISS) for the neutral-point-clamped (NPC) full bridge. In proposed ISS, only one capacitor participates in the energy transfer when the output voltage polarity of the NPC full bridge remains unchanged. Capacitor voltage imbalance will induce a DC bias in the transformer current, thereby facilitating capacitor voltage balancing. Finally, experimental results are provided to validate the effectiveness of the proposed balancing method.

12 January 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJiayun Liu
Jiayun Liu
CTCheng Tang
Cheng Tang
JHJiayu Hu
Jiayu Hu
QXQianming Xu
Qianming Xu
PGPeng Guo
Peng Guo
ZSZhikang Shuai
Zhikang Shuai
The symmetrical phase-shift modulation of the three-to-two-level neutral-point-clamped (NPC) dual-active-bridge (DAB) dc–dc converter has more controllable control variables than that of the conventional two-level DAB converter. The increase in control variables leads to an increase in the number of operating modes and inequality constraints, significantly complicating the modulation optimization process. To enhance the efficiency of the converter, this article proposes an optimized quadruple phase-shift (OQPS) modulation considering both conduction losses and switching losses. Five effective operating modes that have the potential to achieve zero-voltage-switching (ZVS) for all switching devices are screened based on the ZVS inequality constraints. The inductor peak current is used as an optimization objective to minimize the conduction losses while satisfying the ZVS inequality constraints. The boundary of the feasible region satisfied by the optimal solution is derived by numerical optimization. Based on this, an improved Lagrange function and Karush–Kuhn–Tucker conditions are proposed to solve the analytical solution of OQPS modulation. Finally, the proposed OQPS modulation is applied to a 1.6-kW prototype to verify the improvement of efficiency. The designed prototype can achieve 96.9% peak efficiency at 300-V input and 150-V output voltages. Compared with previous modulations, the proposed OQPS modulation can achieve the highest efficiency in the full power range.

1 July 2026 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
JLJiayun Liu
Jiayun Liu
QXQianming Xu
Qianming Xu
JHJiayu Hu
Jiayu Hu
PGPeng Guo
Peng Guo
QXQiaopo Xiong
Qiaopo Xiong
ALAn Luo
An Luo
The three-to-two-level neutral-point-clamped dual active-bridge (3/2LNPC-DAB) DC-DC converter offers higher voltage blocking capability and more control degrees of freedom (DoFs) compared to the conventional two-level DAB converter. However, the screening of modes and optimization of modulation in the time-domain analysis of the 3/2LNPC-DAB converter is highly challenging due to the increase of the control DoFs. In this paper, a visualized modal optimization method is proposed to minimize the current stress. For the 3/2LNPC-DAB converter, five optimization principles for minimizing current stress (FOP MCS) are summarized to screen the optimal modes, and the equational constraints among the four control DoFs in the optimal modes are derived. On this basis, the current stress minimization modulation with an analytical solution in the entire power range can be solved by combining the Karush–Kuhn Tucker (KKT) conditions. Finally, the effectiveness of the proposed modulation is validated by a 1.6 kW prototype. With the proposed modulation, the current stress of the converter is significantly reduced while the efficiency is improved.