Jose L. Azcue-Puma

Jose L. Azcue-Puma

Auto-generated profile, based on publicly available information

Jose L. Azcue-Puma

FEEC/UNICAMP, Campinas-SP, Brazil 13083-970

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2014 in Computers & Mathematics with Applications
Verified
Journal Article
Closed access
CCCarlos Capovilla
Carlos Capovilla
ICI.R.S. Casella
I.R.S. Casella
AFA.J. Sguarezi Filho
A.J. Sguarezi Filho
JAJ.L. Azcue-Puma
J.L. Azcue-Puma
RJR.V. Jacomini
R.V. Jacomini
ERE. Ruppert
E. Ruppert

22 November 2013 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
ICIvan Casella
Ivan Casella
CCCarlos Capovilla
Carlos Capovilla
Alfeu J. Sguarezi FilhoAlfeu J. Sguarezi Filho
Alfeu J. Sguarezi Filho
RJR. V. Jacomini
R. V. Jacomini
JAJ. L. Azcue-Puma
J. L. Azcue-Puma
EFErnesto Ruppert B. Filho
Ernesto Ruppert B. Filho

1 August 2010
Verified
Conference Paper
Closed access
JPJose L. Azcue P.
Jose L. Azcue P.
ERErnesto Ruppert
Ernesto Ruppert
The Direct Torque Control (DTC) with Space Vector Modulation (SVM) and Self-Tuning PI-Type Fuzzy (STPIF) controller is proposed. This controller determines dynamically the load angle between stator and rotor flux vectors and in consequence the electromagnetic torque necessary to supply the motor load. The rule base for STPIF controller is defined in function of the error “e” and the change of the error “Δe” of the torque using a most natural and unbiased membership functions (MF). Constant switching frequency and low torque ripple are obtained using SVM. Performance of the proposed DTC-SVM with STPIF are compared with the performance of the same scheme but using PI controller in terms of several performance measures such as settling time, rise time and integral-of-time multiplied by the absolute magnitude of the error index (ITAE). The simulation results show that the proposed scheme can ensure fast torque response and low torque ripple in comparison with DTC-SVM with PI controller.

8 November 2023 in IEEE Access
Verified
Journal Article
Open access
JCJuan Carlos Colque
Juan Carlos Colque
ERErnesto Ruppert
Ernesto Ruppert
IDI. Delgado-Huayta
I. Delgado-Huayta
KCKarlos A. C. Chirapo
Karlos A. C. Chirapo
JAJosé Luis Azcue
José Luis Azcue
The modular multilevel converter has gained popularity in various applications, including photovoltaic (PV) solar energy conversion. Its modular structure allows for the transformation of an MMC into an MMC-based photovoltaic system, sharing key operational characteristics such as modularity, flexibility, redundancy, increased efficiency, and fault tolerance. To ensure the reliability and uninterrupted operation of the modified MMC, even in the event of potential failures in the photovoltaic submodules (PVSMs), a fault-tolerant strategy is developed in this study. It assumes that the Maximum Power Point Tracking (MPPT) of the PVSMs is already guaranteed. Redundant submodules (rSM) are utilized to maintain power balance between the converter arms through voltage control, while reserve submodules (RSMs) are in place to rescue the converter in case of a failure. The detection and localization of faults in the PVSMs/rSMs are achieved through sliding mode observers (SMOs), and the converter reconfiguration is carried out using the proposed permutation algorithms for switching signals and SMs voltages. For precise control of the output current and electrical grid connection, the dq -reference frame control method is employed. To validate these proposed algorithms, time-domain simulations are conducted using the Simulink/Matlab software.

23 November 2013 in Journal of Control, Automation and Electrical Systems
Verified
Journal Article
Closed access
PDF file
JAJosé L. Azcue-Puma
José L. Azcue-Puma
Alfeu J. Sguarezi FilhoAlfeu J. Sguarezi Filho
Alfeu J. Sguarezi Filho
EFErnesto Ruppert B. Filho
Ernesto Ruppert B. Filho

1 September 2011
Verified
Conference Paper
Closed access
JPJose L. Azcue P.
Jose L. Azcue P.
Alfeu J. Sguarezi FilhoAlfeu J. Sguarezi Filho
Alfeu J. Sguarezi Filho
ERErnesto Ruppert
Ernesto Ruppert
In this paper is proposed a Takagi-Sugeno Fuzzy controller (TSF) applied to the direct torque control scheme with space vector modulation. In conventional DTC-SVM scheme, two PI controllers are used to generate the reference stator voltage vector. To improve the drawback of this conventional DTC-SVM scheme is proposed the TSF controller to substitute both PI controllers. The proposed controller calculates the reference quadrature components of the stator voltage vector. The rule base for the proposed controller is defined in function of the stator flux error and the electromagnetic torque error using trapezoidal and triangular membership functions. Constant switching frequency and low torque ripple are obtained using space vector modulation technique. Performance of the proposed DTC-SVM with TSF controller is analyzed in terms of several performance measures such as rise time, settling time and torque ripple considering different operating conditions. The simulation results shown that the proposed scheme ensure fast torque response and low torque ripple validating the proposed scheme.