15 August 2022 in IEEE Transactions on Industry Applications
An overmodulation method is proposed for an in-wheel system where two motors are coupled to a sum gear. In the dual-motor dual-inverter single shaft systems, the output voltage magnitudes of two inverters are not the same in the overmodulation range due to the angle offset between two motors. In this paper, to maintain torque balance in the overmodulation region, holding vectors are defined between adjacent vertices of two voltage hexagons. Around these vectors, the holding region is also defined by the holding angle. If a reference voltage vector is in the holding region, it is modulated to the holding vector. Otherwise, it is modulated to the vector on the arc of inscribed circle. For a given the modulation index (MI), the holding angle is obtained based on the Fourier series expansion. The proposed method keeps the output voltages of two inverters the same even if two motors have the angle offset. Further, it has the characteristic of maintaining the linearity between the reference and output MI to the maximum MI. The proposed overmodulation method is demonstrated by simulation and experimental results.
17 November 2021 in IEEE Transactions on Industry Applications
With a single shunt resistor, it is possible to sense the phase currents, although some dead regions exist around vertices of the voltage hexagon. In this paper, an overmodulation method is presented for such single current shunt inverters. Regions near vertices of voltage hexagon are defined as holding regions, and the rest are defined as linear regions. The overmodulation strategy is developed based on the Fourier analysis: The magnitude of reference voltage determines the arc radius in the linear region and the holding angle of the holding region. By adjusting either the arc radius or the holding angle, the desired modulation index (MI) can be output. It is particularly useful for low-cost inverters, since it is implemented with an additional look-up table for induction motor or PMSM control. The linearity is maintained between the reference MI and its output MI until it reaches to the maximum, 12-step operation. In addition, the technique provides the seamless transition from space vector modulation to 12-step operation. The effectiveness is evidenced by the experimental results.
5 August 2025 in IEEE Access
Copper loss minimization schemes are widely used to control interior permanent magnet synchronous motors. In the field-weakening region, the maximum torque per ampere cannot be used due to the voltage limit set by the inverter DC-link voltage. It can be avoided when a high-voltage battery or a boost converter is used in the upstream of the inverter. In such cases, copper loss decreases as the current magnitude decreases. However, higher voltages may increase iron losses. In this article, a control method is investigated to minimize the sum of copper and iron losses. The loss sum is derived as a second-order function of a single flux variable, and the local minimum is determined analytically using the proposed approximation method. The proposed method offers several advantages, including high computational efficiency through analytical determination of the optimal operating point, reliable performance with acceptable approximation errors across various torque and speed conditions, and cost-effectiveness by eliminating the need for extensive dynamometer-based testing. Finally, the study is extended with an application to electric vehicle traction motors. Through simulation and experimental results, the benefits of the proposed control scheme are verified.
30 January 2025 in IEEE Transactions on Industry Applications
A simple active-short-circuit (ASC) method is proposed for air conditioning systems with compressors and voltage source inverters (VSI) using a single current sensor. The open-circuit operation for stopping the motors may cause inverter failure due to high regenerated energy. Thus, the ASC method can be an alternative. However, VSIs with a single shunt-resistor connected to dc-link are not able to measure the motor phase currents during the ASC operation. So, it is impossible to protect inverters and motors against high short-currents during ASC. Consequently, it is challenging to apply ASC safely for a low-cost inverter. In this article, open-circuit and ASC are sequentially applied to stop the motor. The motor speed is estimated using a mechanical motor dynamics during the open-circuit operation. When the estimated speed is equal to the preset target speed, the ASC operation is started. It can produce sufficient brake torque and reduce the magnitude of the short-current. The effectiveness of the proposed method is validated by simulations and experimental results using a calorimeter chamber.