15 August 2022 in IEEE Transactions on Industry Applications
An overmodulation method is proposed for an in-wheel system where two motors are coupled to a sum gear. In the dual-motor dual-inverter single shaft systems, the output voltage magnitudes of two inverters are not the same in the overmodulation range due to the angle offset between two motors. In this paper, to maintain torque balance in the overmodulation region, holding vectors are defined between adjacent vertices of two voltage hexagons. Around these vectors, the holding region is also defined by the holding angle. If a reference voltage vector is in the holding region, it is modulated to the holding vector. Otherwise, it is modulated to the vector on the arc of inscribed circle. For a given the modulation index (MI), the holding angle is obtained based on the Fourier series expansion. The proposed method keeps the output voltages of two inverters the same even if two motors have the angle offset. Further, it has the characteristic of maintaining the linearity between the reference and output MI to the maximum MI. The proposed overmodulation method is demonstrated by simulation and experimental results.
5 August 2025 in IEEE Access
Copper loss minimization schemes are widely used to control interior permanent magnet synchronous motors. In the field-weakening region, the maximum torque per ampere cannot be used due to the voltage limit set by the inverter DC-link voltage. It can be avoided when a high-voltage battery or a boost converter is used in the upstream of the inverter. In such cases, copper loss decreases as the current magnitude decreases. However, higher voltages may increase iron losses. In this article, a control method is investigated to minimize the sum of copper and iron losses. The loss sum is derived as a second-order function of a single flux variable, and the local minimum is determined analytically using the proposed approximation method. The proposed method offers several advantages, including high computational efficiency through analytical determination of the optimal operating point, reliable performance with acceptable approximation errors across various torque and speed conditions, and cost-effectiveness by eliminating the need for extensive dynamometer-based testing. Finally, the study is extended with an application to electric vehicle traction motors. Through simulation and experimental results, the benefits of the proposed control scheme are verified.
10 April 2024 in IEEE Transactions on Transportation Electrification
A closed-loop active short circuit method is developed for PMSM to suppress the transient oscillating current and torque. Active short circuit inherently shuts down the inverter and motor side, and is used as a safe state in electric drive systems based on PMSM. However, when the motor has an active short circuit at medium/high speeds, the system has insufficient damping, resulting in overcurrent and oscillating currents. To mitigate it, another safe state, freewheeling, is injected into the active short circuit operation. The output voltage determined by the motor current angle in freewheeling operation was straightforwardly derived. Then, a modulation method with two safe states is proposed by combining active short circuit and freewheeling operation. An appropriate freewheeling time should be calculated to avoid dc-link overvoltage due to freewheeling. For this reason, a d-axis current feedback algorithm with a high pass filter was implemented. The proposed algorithm was analyzed by root locus method to improve the damping of the system. In addition, the unstable freewheeling voltage angle region was calculated using the Routh-Hurwitz criterion. The proposed method is demonstrated by simulations and experimental results at 2400 rev/min.
30 January 2025 in IEEE Transactions on Industry Applications
A simple active-short-circuit (ASC) method is proposed for air conditioning systems with compressors and voltage source inverters (VSI) using a single current sensor. The open-circuit operation for stopping the motors may cause inverter failure due to high regenerated energy. Thus, the ASC method can be an alternative. However, VSIs with a single shunt-resistor connected to dc-link are not able to measure the motor phase currents during the ASC operation. So, it is impossible to protect inverters and motors against high short-currents during ASC. Consequently, it is challenging to apply ASC safely for a low-cost inverter. In this article, open-circuit and ASC are sequentially applied to stop the motor. The motor speed is estimated using a mechanical motor dynamics during the open-circuit operation. When the estimated speed is equal to the preset target speed, the ASC operation is started. It can produce sufficient brake torque and reduce the magnitude of the short-current. The effectiveness of the proposed method is validated by simulations and experimental results using a calorimeter chamber.
23 April 2024 in IEEE Access
The open-loop current transducer comprises a magnetic core made of soft magnet material and includes a Hall sensor. Traction motors in applications such as electric vehicles tend to be driven at high speeds. It pushes the inverters to increase the fundamental frequency of the output current above 1 kHz. However, this high frequency current generates eddy currents in the magnetic core of the current transducers. They deteriorate the measurement data thereby resulting the amplitude error and phase shift error, which is applied open-loop current transducer with the lamination magnetic core. In this study, the errors of an open-loop current transducer due to eddy currents were analyzed through mathematical modeling and finite element method (FEM). Furthermore, the impact of the error on permanent magnet synchronous motor current control was studied. The phase shift error of the current transducer used in this study reaches 3.6 degree when the frequency of current was 1.5 kHz, resulting in about a 20% torque reduction during field-weakening operation at 200 kW, 22500 rpm. On the other hand, the amplitude error of the current transducer is only 0.18% in the same condition. In order to correct the error, an online compensation method is proposed based on FEM simulation results. The phase shift error was verified through the experiments with a $300~\mu H$ , 3-phase inductive load. The proposed method was also validated through the experimental results conducted for variable frequencies from 500 Hz to 1.5 kHz.