6 May 2024 in Nature Biomedical Engineering
Myocardial microvasculature and haemodynamics are indicative of potential microvascular diseases for patients with symptoms of coronary heart disease in the absence of obstructive coronary arteries. However, imaging microvascular structure and flow within the myocardium is challenging owing to the small size of the vessels and the constant movement of the patient’s heart. Here we show the feasibility of transthoracic ultrasound localization microscopy for imaging myocardial microvasculature and haemodynamics in explanted pig hearts and in patients in vivo. Through a customized data-acquisition and processing pipeline with a cardiac phased-array probe, we leveraged motion correction and tracking to reconstruct the dynamics of microcirculation. For four patients, two of whom had impaired myocardial function, we obtained super-resolution images of myocardial vascular structure and flow using data acquired within a breath hold. Myocardial ultrasound localization microscopy may facilitate the understanding of myocardial microcirculation and the management of patients with cardiac microvascular diseases.
23 October 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Super-resolution ultrasound (SRUS) can image microvascular structure and flow at subwave-diffraction resolution based on localizing and tracking microbubbles (MBs). Currently, tracking MBs accurately under limited imaging frame rates and high MB concentrations remains a challenge, especially under the effect of cardiac pulsatility and in highly curved vessels. In this study, an acceleration-incorporated MB motion model is introduced into a Kalman tracking framework. The tracking performance was evaluated using simulated microvasculature with different MB motion parameters, concentrations, and acquisition frame rates, and in vivo human breast tumor US datasets. The simulation results show that the acceleration-based method outperformed the nonacceleration-based method at different levels of acceleration and acquisition frame rates and achieved significant improvement in true positive rate (TPR; up to 11.3%) and false negative rate (FNR; up to 13.2%). The proposed method can also reduce errors in vasculature reconstruction via the acceleration-based nonlinear interpolation, compared with linear interpolation (up to $16.7~\mu \text{m}$ ). The tracking results from temporally downsampled low frame rate in vivo datasets from human breast tumors show that the proposed method has better MB tracking performance than the baseline method, if using results from the initial high frame data as a reference. Finally, the acceleration estimated from tracking results also provides a spatial speed gradient map that may contain extra valuable diagnostic information.
28 March 2025 in JACC: Clinical Electrophysiology
The restriction of activation mapping to the ventricular surface of contemporary mapping systems often leads to failure to correctly identify the true sites of origin (SoOs) of intramural and/or subepicardial ventricular arrhythmias (VAs), reducing procedural success. The aim of this study was to evaluate if noninvasive electromechanical wave imaging (EWI) can locate the SoOs of VAs along the endo-epicardial axis in patients with and without structural heart disease. Patients with VAs requiring ablation underwent preprocedural transthoracic EWI to identify the SoOs and validate using contact mapping. Local electromechanical activation was defined as time point of the downward zero crossing on the incremental axial strain curve. The site of earliest activation on contact mapping and/or successful ablation was employed as ground truth for VA SoO. Twenty-eight patients underwent EWI, and 25 proceeded to contact mapping (56% men, mean age 53 ± 16 years, mean left ventricular ejection fraction 47% ± 28%, 52% with late gadolinium enhancement (LGE) on magnetic resonance imaging). Five patients were excluded (insufficient or different ventricular tachycardia or ventricular ectopic activity at the time of EWI vs contact mapping). EWI mapping correctly localized the VA SoOs in 17 of 20 (85%) of the cases and mapped them to the adjacent segments in the remaining ones. In the presence of scar, EWI localized 81.8% of the VA SoOs (n = 9 of 11) correctly compared with 88.9% (n = 8 of 9) in patients without (P = NS). The transmural SoOs (endocardial, midmyocardial, or epicardial) were successfully identified in 18 of 20 cases (90%; P = NS for LGE-positive vs LGE-negative patients). EWI correctly identified the transmural SoOs of focal VAs, including in the presence of scar, in the majority of cases using contact mapping as the gold standard and thus could support preprocedural planning, including requirement for epicardial access and/or ablation techniques. The absence of a true gold standard for clinical transmural mapping remains an important challenge for the validation of novel mapping technologies.
1 October 2024 in Circulation: Cardiovascular Imaging
23 July 2025 in JACC: Cardiovascular Imaging