11 April 2019 in Scientific Reports
Room-temperature liquid metal has been widely used in flexible and stretchable sensors, focusing on embedding liquid metal in microchannels, liquid metal microdroplets formation, captive sensors, and liquid metal nanoparticles, etc. In this paper, a facile Eutectic Galium-Indium (EGaln) liquid-based microfluidic high-sensitivity, skin-mountable, and ultra-soft stretchable sensor is developed. It comprises Ecoflex microfluidic assembly filled with EGaln, which serves as the working fluid of the stretchable sensor. The lithography method is applied to achieve microfluidic channel. The microfluidic channel is optimized by using topology method and finite element analysis, making this device with high conformability and high stretchability. This method achieved an outstanding effect on elastomer-encapsulated strain gauge, which displays an approximately linear behavior with a gauge factor (GF). The GF could reach as high as 4.95 when the strain ultimately reached 550%. Applications of detection of the joints, fingers, and wrists has been conducted and showed excellent results. This work can further facilitate the exploration and potential realization of a functional liquid-state device technology with superior mechanical flexibility and conformability.
28 November 2018 in Journal of Materials Science
1 November 2021 in Annual International Conference of the IEEE Engineering in Medicine and Biology Society
Amplitude shift keying (ASK) data demodulation method has been widely used for simultaneous wireless data and power transfer in implantable medical devices (IMDs). Small amplitude modulation depth (MD) is usually preferred as it helps promote energy harvesting efficiency. This paper presents an ASK data demodulator that has good immunity to disturbances and can demodulate ultra-low MD ASK signal. A three-stage amplifying structure (3SAS) is proposed, in which the common-mode level of each amplifier is set between the high and low levels of its input signal envelope to prevent amplifier gain saturation and maximize the amplification of the envelope difference. Two envelope detectors (EDs) are used before and after the 3SAS respectively. The first one is to obtain a coarse envelope for 3SAS input and the second one is to further suppress the residual carrier interference and get a fine envelope. The proposed demodulator is implemented in 0.18-μm high-voltage Bipolar-CMOS-DMOS (BCD) technology. The detectable MD is measured as low as 0.034%, showing that the proposed demodulator can work smoothly and robustly in some extreme cases of simultaneous data and power transferring.Clinical Relevance— The ASK data demodulator proposed in this paper supports ultra-low modulation depth. This reduces the bit error rate of the data link and keeps a highly power conversion efficiency for wireless power and data transfer in implantable medical devices.