Lei Wang

Dr. Lei Wang

Shenzhen Institute of Advanced Technology, Chinese Academy of Sciences, Shenzhen, China
orcid

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 February 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJing Chen
Jing Chen
JZJiahong Zheng
Jiahong Zheng
QGQinwu Gao
Qinwu Gao
JZJinjie Zhang
Jinjie Zhang
JZJinyong Zhang
Jinyong Zhang
HLHui Li
Hui Li
There is growing attention and rapid development on flexible electronic devices with electronic materials and sensing technology innovations. In particular, strain sensors with high elasticity and stretchability are needed for several potential applications including human entertainment technology, human–machine interface, personal healthcare, and sports performance monitoring, etc. This article presents recent advancements in the development of polydimethylsiloxane (PDMS)-based flexible resistive strain sensors for wearable applications. First of all, the article shows that PDMS-based stretchable resistive strain sensors are successfully fabricated by different methods, such as the filtration method, printing technology, micromolding method, coating techniques, and liquid phase mixing. Next, strain sensing performances including stretchability, gauge factor, linearity, and durability are comprehensively demonstrated and compared. Finally, potential applications of PDMS-based flexible resistive strain sensors are also discussed. This review indicates that the era of wearable intelligent electronic systems has arrived.

16 October 2020 in IEEE Transactions on Systems, Man, and Cybernetics: Systems
Verified
Journal Article
Closed access
Olatunji OmisoreOlatunji Omisore
Olatunji Omisore
SHShipeng Han
Shipeng Han
JXJing Xiong
Jing Xiong
HLHui Li
Hui Li
RTRaymond Kai-yu Tong
Raymond Kai-yu Tong
Lei WangLei Wang
Lei Wang
Recently, flexible robotic systems are developed to enhance minimally invasive interventions on internal organs located in confined areas of human body. These surgical devices are designed to navigate anatomical pathways via single-port access, such as natural orifices or minimal incisions and intraluminal interventions. With improved precision, spatial flexibility and dexterity, the robotic technology can enhance surgery such that minimally invasive flexible access would become a faster, safer, and more convenient method for intra-body interventions without multiple or wide incisions. However, a lot of works are still required for global acceptance of existing flexible robotic surgical platforms. This review provides extended insights on the design details of two types of flexible robotic systems used for endoscopic and endovascular procedures. As of today, several prototypes of both platforms have been proposed; however, their global acceptability and applicability remains very low. To address these, we present an extensive review on design constraints and control methods which are vital for safer, faster, and better operation of the flexible robotic systems in minimally invasive surgery (MIS). Finally, research trends of flexible robotic systems and their clinical application status in MIS are discussed along with some of the technical and technological challenges hindering their prominence.

9 October 2020 in Science Advances
Verified
Journal Article
Open access
PDF file
NHNi Huang
Ni Huang
LWLi Wang
Li Wang
XSXiao-Peng Song
Xiao-Peng Song
TBT. Andrew Black
T. Andrew Black
RJRachhpal S. Jassal
Rachhpal S. Jassal
ZNZheng Niu
Zheng Niu
Soil respiration (Rs) represents the largest flux of CO2 from terrestrial ecosystems to the atmosphere, but its spatial and temporal changes as well as the driving forces are not well understood. We derived a product of annual global Rs from 2000 to 2014 at 1 km by 1 km spatial resolution using remote sensing data and biome-specific statistical models. Different from the existing view that climate change dominated changes in Rs, we showed that land-cover change played a more important role in regulating Rs changes in temperate and boreal regions during 2000–2014. Significant changes in Rs occurred more frequently in areas with significant changes in short vegetation cover (i.e., all vegetation shorter than 5 m in height) than in areas with significant climate change. These results contribute to our understanding of global Rs patterns and highlight the importance of land-cover change in driving global and regional Rs changes.

2 August 2019 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
TITobore Igbe
Tobore Igbe
JLJingzhen Li
Jingzhen Li
LYLiu Yuhang
Liu Yuhang
YAYousef Al-handarish
Yousef Al-handarish
AKAbhishek Kandwal
Abhishek Kandwal
Lei WangLei Wang
Lei Wang
The use of deep learning (DL) for the analysis and diagnosis of biomedical and health care problems has received unprecedented attention in the last decade. The technique has recorded a number of achievements for unearthing meaningful features and accomplishing tasks that were hitherto difficult to solve by other methods and human experts. Currently, biological and medical devices, treatment, and applications are capable of generating large volumes of data in the form of images, sounds, text, graphs, and signals creating the concept of big data. The innovation of DL is a developing trend in the wake of big data for data representation and analysis. DL is a type of machine learning algorithm that has deeper (or more) hidden layers of similar function cascaded into the network and has the capability to make meaning from medical big data. Current transformation drivers to achieve personalized health care delivery will be possible with the use of mobile health (mHealth). DL can provide the analysis for the deluge of data generated from mHealth apps. This paper reviews the fundamentals of DL methods and presents a general view of the trends in DL by capturing literature from PubMed and the Institute of Electrical and Electronics Engineers database publications that implement different variants of DL. We highlight the implementation of DL in health care, which we categorize into biological system, electronic health record, medical image, and physiological signals. In addition, we discuss some inherent challenges of DL affecting biomedical and health domain, as well as prospective research directions that focus on improving health management by promoting the application of physiological signals and modern internet technology.

5 March 2021 in Nano Research
Verified
Journal Article
Closed access
PDF file
YTYongsong Tan
Yongsong Tan
KYKun Yang
Kun Yang
BWBo Wang
Bo Wang
HLHui Li
Hui Li
Lei WangLei Wang
Lei Wang
CWChaoxia Wang
Chaoxia Wang
With the increasing demand for smart wearable clothing, the textile piezoelectric pressure sensor (T-PEPS) that can harvest mechanical energy directly has attracted significant attention. However, the current challenge of T-PEPS lies in remaining the outstanding output performance without compromising its wearing comfort. Here, a novel structural hierarchy T-PEPS based on the single-crystalline ZnO nanorods are designed. The T-PEPS is constructed with three layers mode consisting of a polyvinylidene fluoride (PVDF) membrane, the top and bottom layers of conductive rGO polyester (PET) fabrics with self-orientation ZnO nanorods. As a result, the as-fabricated T-PEPS shows low detection limit up to 8.71 Pa, high output voltage to 11.47 V and superior mechanical stability. The sensitivity of the sensor is 0.62 V·kPa−1 in the pressure range of 0–2.25 kPa. Meanwhile, the T-PEPS is employed to detect human movements such as bending/relaxation motion of the wrist, bending/stretching motion of each finger. It is demonstrated that the T-PEPS can be up-scaled to promote the application of wearable sensor platforms and self-powered devices.

1 November 2011 in Telemedicine and e-Health
Verified
Journal Article
Open access
GLGuan-Zheng Liu
Guan-Zheng Liu
YGYan-Wei Guo
Yan-Wei Guo
QZQing-Song Zhu
Qing-Song Zhu
BHBang-Yu Huang
Bang-Yu Huang
Lei WangLei Wang
Lei Wang
Respiratory monitoring is widely used in clinical and healthcare practice to detect abnormal cardiopulmonary function during ordinary and routine activities. There are several approaches to estimate respiratory rate, including accelerometer(s) worn on the torso that are capable of sensing the inclination changes due to breathing. In this article, we present an adaptive band-pass filtering method combined with principal component analysis to derive the respiratory rate from three-dimensional acceleration data, using a body sensor network platform previously developed by us. In situ experiments with 12 subjects indicated that our method was capable of offering dynamic respiration rate estimation during various body activities such as sitting, walking, running, and sleeping. The experimental studies also suggested that our frequency spectrum-based method was more robust, resilient to motion artifact, and therefore outperformed those algorithms primarily based on spatial acceleration information.