Tevhit Karacali

Tevhit Karacali

Auto-generated profile, based on publicly available information

Tevhit Karacali

Department of Electrical and Electronics Engineering, Ataturk University, 25240 Erzurum, Türkiye

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2015 in Applied Surface Science
Verified
Journal Article
Closed access
HEHasan Efeoglu
Hasan Efeoglu
SGSüheyla Güllülü
Süheyla Güllülü
TKTevhit Karacali
Tevhit Karacali

19 May 2003 in Optics Express
Verified
Journal Article
Closed access
PDF file
TKTevhit Karacali
Tevhit Karacali
BCBulent Cakmak
Bulent Cakmak
HEHasan Efeoglu
Hasan Efeoglu
Aging effects of porous silicon (PS) and the origin of blue shift are investigated. Photoluminescence (PL) measurements of the PS prepared with HF-EtOH solution showed a 210 meV blue shift after 1.5 months. It is found from deconvolution of the PL spectra that this shift is not fully related to the quantum confinement (QC) effect. For stable PS formation, a HF-EtOH-H2O2 solution is used. A stable luminescence at 2.01 eV with a Gaussian distribution is obtained when the samples are kept in H2O2 for 45 min after the anodization.

13 September 2012 in Optics Express
Verified
Journal Article
Closed access
PDF file
UHU. C. Hasar
U. C. Hasar
IOI. Y. Ozbek
I. Y. Ozbek
EOE. A. Oral
E. A. Oral
TKT. Karacali
T. Karacali
HEH. Efeoglu
H. Efeoglu
In this paper, we investigate the effect of non-uniformities (enlargement of current passage, non-equal surface current densities, etc.) in axial as well as transverse directions of a porous silicon Fabry-Perot (FP) cavity as well as loss nature of bulk silicon on spectral properties of this cavity, even that cavity is created with an anisotropic etching process. Without correct and comprehensive characterization of such cavities by incorporating these non-uniformities and inherent lossy nature of a cavity, detection and identification of biological and chemical molecules by that cavity may yield unpredictable and misleading results. From our simulations, we note the following two key points. First, effects of the refractive index and the thickness of microcavity region of a lossless or lossy FP cavity on resonance wavelength is more prevailing than those of first and last layers. Second, the effect of some small loss inside the FP cavity is not detectable by the measurement of resonance wavelength whereas the same influence is noticeable by the measurement of reflectivity. We carried out some measurements from two different regions on the fabricated cavities to validate our simulation results. From a practical point of view in correct detection and/or identification of lossy biological or chemical vapor by FP cavities, we conclude that not only the measurement of resonance wavelength as well as its shift but also the reflectivity value at the resonance wavelength or some specific wavelengths should be utilized.

1 January 2017 in Results in Physics
Verified
Journal Article
Open access
MBMehmet Biber
Mehmet Biber
ŞAŞakir Aydoğan
Şakir Aydoğan
ZÇZakir Çaldıran
Zakir Çaldıran
BÇBülent Çakmak
Bülent Çakmak
TKTevhit Karacalı
Tevhit Karacalı
ATAbdulmecit Türüt
Abdulmecit Türüt
In this study, fabrication of a polycyclic aromatic hydrocarbon/Perylene Tetracarboxylic Di-Imide (PTCDI), donor/acceptor solar cells are presented using physical vapour deposition technique in a 1000 class glove box. An ITO/PEDOT:PSS/Pentacene/PTCDI/Al (ITO = Indium Tin Oxide and PEDOT:PSS = poly(3,4-ethylenedioxythiophene) polystyrene sulfonate) solar cell has been obtained and the power conversion efficiency, PCE (η) of about 0.33% has been obtained under simulated solar illumination of 300 W/m2. Furthermore, the effects of annealing temperatures (at 100 and 150 °C) and of annealing (at 100 °C) times for 5 and 10 min. on the power conversion efficiency, η of the solar cells have also been investigated. In general, it has been seen that the thermal annealing deteriorated the characteristics parameters of Pentacene/PTCDI solar cell such that both fill factor, FF and η decreased after annealing and with increase of annealing time. Atomic force microscopy (AFM) images showed that the phase segregation and grain size increased and the surface roughness of Pentacene film decreased and these effects reduced the η value. The η values of the solar cell have been determined as 0.33%, 0.12% and 0.06% for pre-annealing, annealing at 100 and 150 °C, respectively. Keywords: Organic solar cells, PTCDI, Pentacene, Annealin

1 June 2015 in Electrochimica Acta
Verified
Journal Article
Closed access
MGMurat Gülnahar
Murat Gülnahar
TKTevhit Karacali
Tevhit Karacali
HEHasan Efeoğlu
Hasan Efeoğlu

20 October 2009 in IEEE Sensors Journal
Verified
Journal Article
Closed access
TKTevhit Karacali
Tevhit Karacali
MAMurat Alanyalioglu
Murat Alanyalioglu
HEHasan Efeoglu
Hasan Efeoglu
This paper presents sensing of chemicals using porous silicon as optical sensor fabricated by periodically modulating the porosity of silicon to produce multilayered structures. Single and double Fabry-Perot (FP) structure is designed by using electrochemical anodical etching technique. The operation of chemical sensor is based on the change of effective refractive index of the porous silicon medium, induced by condensation of solvent vapors around the pillars. Resonant wavelengths of single and double multilayer with a microcavity have presented a red shift when exposed to vapor of solvents. On the other hand, resonant wavelength of double FP structure sandwiched with a diffusion layer has presented different optical response when exposed to vapor of solvents. This structure actually has two stop bands with two resonant wavelengths. While of the beginning first and second stop band and resonant wavelength shift together to the infrared region continuously, after awhile second stop band stopped but the first stop band continued to shifting to the infrared region. Time dependence of optical response of proposed structure can be used for identification chemicals.