Lei Jia

Lei Jia

Auto-generated profile, based on publicly available information

Lei Jia

School of Electric and Engineering, University of South China, Hengyang, China

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2016
Verified
Conference Paper
Closed access
HCHansheng Cai
Hansheng Cai
LJLei Jia
Lei Jia
GLGang Liu
Gang Liu
SHShangmao Hu
Shangmao Hu
Jian ShiJian Shi
Jian Shi
JHJunjia He
Junjia He
Lightning stroke is the main cause of trip-outs of EHV and UHV transmission lines in China Southern Power Grid (CSG). In order to improving the lightning performance of overhead transmission lines, the lightning activities of CSG in 2006 to 2014 was analyzed. It indicates that the coastal Guangdong and Guangxi province are suffered more ground flashes, where the average ground flash density is over 7.98 flashes/km 2 /year. 306 lightning flashover incidents of 500kV AC, ± 500kV HVDC and ± 800kV UHVDC transmission lines were investigated. It is inferred that about 84% lightning flashover incidents was caused by lightning shielding failure. The corresponding ground wire protection angle for 81% incidents is larger than 5°, and with protection angle decreases, lightning trip-out failures are significantly reduced. Based on the guidelines proposed by IEEE and CIGRE working group, CSG has developed their own lightning risk estimation tool named LPTL. The predication result of six 500kV AC transmission lines was compared to field experience which validates the IEEE recommended method for 500kV AC transmission lines. Further works should be done to revisit the validity of existing risk estimation method for HVDC transmission lines.

8 December 2023
Verified
Conference Paper
Closed access
Meng GaoMeng Gao
Meng Gao
RZRan Zhuo
Ran Zhuo
SZSicheng Zhao
Sicheng Zhao
QCQiulin Chen
Qiulin Chen
MFMingli Fu
Mingli Fu
GWGuoli Wang
Guoli Wang
Intelligent operation and maintenance of power transformers using digital twin technology is of vital importance for ensuring the safe operation of the power grid. Dynamic simulation and efficient calculation of the thermal characteristics of transformers are key tasks in this area. To achieve fast prediction of temperature rise in transformers under time-varying operating conditions and promote the application of digital twin in substation operation and maintenance, this paper proposes a reduced-order model with full-nodal and multi-time steps output for transient simulation of transformer temperature field based on multi-layer Autoencoder (MAE) and decomposition linear layers (DLinear), and evaluates its effectiveness in terms of computational accuracy and efficiency. The results demonstrate that the proposed reduced-order model for transient simulation achieves high computational accuracy, with a maximum relative error of only 1.82% compared to simulation calculations. At the same time, the model significantly improves computational efficiency, with the ability to make 200-step predictions in only 3s. The research findings of this paper provide strong technical support for monitoring the thermal performance of transformers and the operation and maintenance of substations.

6 September 2020
Verified
Conference Paper
Closed access
Jian ShiJian Shi
Jian Shi
LJLei Jia
Lei Jia
QMQi Mei
Qi Mei
HCHansheng Cai
Hansheng Cai
SHShangmao Hu
Shangmao Hu
HLHao Liu
Hao Liu
The over-voltage level directly affects the selection and insulation design of the main equipment in power station. This paper calculates the over-voltage condition of AC lines and equipment in the converter station of Yunnan-Guangxi-Guangdong UHVDC (ultra-high voltage direct current) project. The suppression method and equipment insulation parameters are proposed. The calculation shows that the shunt reactor has obvious effect on limiting the power frequency over-voltage (PFO) of long-distance line. In order to suppress the resonant over-voltage and the secondary arc current, the installation of the neutral point reactor is recommended. The maximum switching over-voltage (SO) can be limited by installing a $400\Omega$ closing resistor to a AC line breaker. The switching over-voltage can be very large during bi-pole blocking at converter station when DC system passively enters into isolated mode. Multiple measures, such as installing metallic oxide arrester (MOA), control and protection optimization, are taken to reduce the overvoltage. The SO is limited below 1.64 p.u. afterwards. The maximum power frequency transient overvoltage level during bi-pole blocking at converter station is calculated as 1.49 p.u., which does not meet the requirements of the over-voltage regulations and should be specified when selecting equipment. The maximum absorption energy of A type arrester is 4245kJ, which is lower than its rated capacity. This paper studies the over-voltage and its suppression method of AC system and provides the basis for the insulation design of transmission line and the selection of main equipment in converter station.

28 May 2025 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
LJLei Jia
Lei Jia
XCXi Chen
Xi Chen
JXJinfeng Xiao
Jinfeng Xiao
TLTe Lu
Te Lu
The single winding pole-changing rotor structure can be applied in a brushless doubly-fed generator (BDFG) to couple two magnetic fields produced by stator. However, the traditional scheme employing equal turn coils may result in an asymmetric distribution of the magnetomotive force (MMF) phase angles among the parallel branches within each phase. Through comprehensive circuit analysis, it is further revealed that three branches exhibit distinct characteristics in terms of the slots number and spatial arrangement, leading to unbalanced current amplitudes. The structural asymmetries and current imbalance may significantly enrich magnetic field harmonic contents, amplify electromagnetic vibration and noise, generate parasitic circulating current, and increase copper losses. To address these limitations, an improved scheme with unequal turn coils is developed by reconfiguring the rotor wiring mode. The operational characteristics of BDFG with equal turn, unequal turn, and improved schemes are investigated through finite element (FE). Analysis results imply that the improved scheme significantly reduces the MMF angles discrepancies, ensures balanced current distribution across all branches, and simplifies the circuit connection. Finally, experimental results of a prototype BDFG validate the superior of the proposed scheme.

3 March 2026 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
LJLei Jia
Lei Jia
JXJun Xu
Jun Xu
JXJinfeng Xiao
Jinfeng Xiao
The brushless doubly-fed generator (BDFG) is especially well-suited for constant-frequency, constant-voltage power generation in small hydropower plants utilizing variable speed hydraulic turbines. This paper presents a novel wound rotor design that combines long and short pitch coils to consider both the power winding (PW) and control winding (CW) pole pair pitches selection, thereby improving the chording factors and enhancing the overall winding factors through harmonic analysis. First, this study investigates the rotor speed regulation characteristics, analyzes the composition and magnitude of the radial electromagnetic forces density under harmonic-free condition, presents the stator PW and CW connection methods. Subsequently, the principle of employing combined pitch coils is elaborated to further increase conductor utilization and mitigate harmonic contents. A practical design example for 1/3 pole-pair is provided, including detailed implementation steps, along with a comparative analysis of coupling coefficients across different rotor configurations. Furthermore, finite element (FE) analysis of the 2/6-pole BDFG and 8-pole doubly-fed induction generator (DFIG) with identical frame sizes are conducted to evaluate the difference in operational characteristics of the generators under the same load and rotor speed range. Finally, the experimental results validate the superiority of the proposed 2/6-pole BDFG rotor design across diverse loads and speeds.