Joelle Ann Feghali

Joelle Ann Feghali

Auto-generated profile, based on publicly available information

Joelle Ann Feghali

Department of Radiology, Bicêtre University Hospital, Le Kremlin Bicêtre, France

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2022 in Abdominal Radiology
Verified
Journal Article
Closed access
PDF file
MLMaïté Lewin
Maïté Lewin
ALAstrid Laurent-Bellue
Astrid Laurent-Bellue
CDChristophe Desterke
Christophe Desterke
ARAdina Radu
Adina Radu
JFJoëlle Ann Feghali
Joëlle Ann Feghali
CGCatherine Guettier
Catherine Guettier

1 July 2021 in Diagnostic and Interventional Imaging
Verified
Journal Article
Closed access
JFJoelle A. Feghali
Joelle A. Feghali
GCGreg Chambers
Greg Chambers
JDJulie Delépierre
Julie Delépierre
SCSophie Chapeliere
Sophie Chapeliere
IMInès Mannes
Inès Mannes
CACatherine Adamsbaum
Catherine Adamsbaum

27 December 2021 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
JFJoelle Ann Feghali
Joelle Ann Feghali
JDJulie Delépierre
Julie Delépierre
OBOlivera Ciraj Belac
Olivera Ciraj Belac
JDJérémie Dabin
Jérémie Dabin
MDMarine Deleu
Marine Deleu
CTClaire Van Ngoc Ty
Claire Van Ngoc Ty
Background: Patients can be exposed to high skin doses during complex interventional cardiology (IC) procedures. Purpose: To identify which clinical and technical parameters affect patient exposure and peak skin dose (PSD) and to establish dose reference levels (DRL) per clinical complexity level in IC procedures. Material and Methods: Validation and Estimation of Radiation skin Dose in Interventional Cardiology (VERIDIC) project analyzed prospectively collected patient data from eight European countries and 12 hospitals where percutaneous coronary intervention (PCI), chronic total occlusion PCI (CTO), and transcatheter aortic valve implantation (TAVI) procedures were performed. A total of 62 clinical complexity parameters and 31 technical parameters were collected, univariate regressions were performed to identify those parameters affecting patient exposure and define DRL accordingly. Results: Patient exposure as well as clinical and technical parameters were collected for a total of 534 PCI, 219 CTO, and 209 TAVI. For PCI procedures, body mass index (BMI), number of stents ≥2, and total stent length >28 mm were the most prominent clinical parameters, which increased the PSD value. For CTO, these were total stent length >57 mm, BMI, and previous anterograde or retrograde technique that failed in the same session. For TAVI, these were male sex, BMI, and number of diseased vessels. DRL values for Kerma-area product ( PKA), air kerma at patient entrance reference point ( Ka,r), fluoroscopy time (FT), and PSD were stratified, respectively, for 14 clinical parameters in PCI, 10 in CTO, and four in TAVI. Conclusion: Prior knowledge of the key factors influencing the PSD will help optimize patient radiation protection in IC.

6 February 2023 in Acta Radiologica
Verified
Journal Article
Closed access
JFJoelle A Feghali
Joelle A Feghali
RRRoberta A Russo
Roberta A Russo
AMAdel Mamou
Adel Mamou
ALAxel Lorentz
Axel Lorentz
ACAlfredo Cantarinha
Alfredo Cantarinha
OMOlivier Meyrignac
Olivier Meyrignac
Background: Low-dose thoracic protocols were developed massively during the COVID-19 outbreak. Purpose: To study the impact on image quality (IQ) and the diagnosis reliability of COVID-19 low-dose chest computed tomography (CT) protocols. Material and Methods: COVID-19 low-dose protocols were implemented on third- and second-generation CT scanners considering two body mass index (BMI) subgroups (25 kg/m2). Contrast-to-noise ratios (CNR) were compared with a Catphan phantom. Next, two radiologists retrospectively assessed IQ for 243 CT patients using a 5-point Linkert scale for general IQ and diagnostic criteria. Kappa score and Wilcoxon rank sum tests were used to compare IQ score and CTDIvol between radiologists, protocols, and scanner models. Results: In vitro analysis of Catphan inserts showed in majority significantly decreased CNR for the low dose versus standard acquisition protocols on both CT scanners. However, in vivo, there was no impact on the diagnosis: sensitivity and specificity were ≥0.8 for all protocols and CT scanners. The third-generation scanner involved a significantly lower dose compared to the second-generation scanner (CTDIvol of 1.8 vs. 2.6 mGy for BMI 25 kg/m2). Still, the third-generation scanner showed a significantly higher IQ with the low-dose protocol compared to the second-generation scanner (30.9 vs. 28.1 for BMI 25 kg/m2). Finally, the two radiologists had good global inter-reader agreement (kappa ≥0.6) for general IQ. Conclusion: Low-dose protocols provided sufficient IQ independently of BMI subgroups and CT models without any impact on diagnosis reliability.

22 December 2021 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
JFJoelle Ann Feghali
Joelle Ann Feghali
JDJulie Delépierre
Julie Delépierre
OBOlivera Ciraj Belac
Olivera Ciraj Belac
JDJérémie Dabin
Jérémie Dabin
MDMarine Deleu
Marine Deleu
CTClaire Van Ngoc Ty
Claire Van Ngoc Ty
Background: Optimizing patient exposure in interventional cardiology is key to avoid skin injuries. Purpose: To establish predictive models of peak skin dose (PSD) during percutaneous coronary intervention (PCI), chronic total occlusion percutaneous coronary intervention (CTO), and transcatheter aortic valve implantation (TAVI) procedures. Material and Methods: A total of 534 PCI, 219 CTO, and 209 TAVI were collected from 12 hospitals in eight European countries. Independent associations between PSD and clinical and technical dose determinants were examined for those procedures using multivariate statistical analysis. A priori and a posteriori predictive models were built using stepwise multiple linear regressions. A fourfold cross-validation was performed, and models’ performance was evaluated using the root mean square error (RMSE), mean absolute percentage error (MAPE), coefficient of determination (R²), and linear correlation coefficient (r). Results: Multivariate analysis proved technical parameters to overweight clinical complexity indices with PSD mainly affected by fluoroscopy time, tube voltage, tube current, distance to detector, and tube angulation for PCI. For CTO, these were body mass index, tube voltage, and fluoroscopy contribution. For TAVI, these parameters were sex, fluoroscopy time, tube voltage, and cine acquisitions. When benchmarking the predictive models, the correlation coefficients were r = 0.45 for the a priori model and r = 0.89 for the a posteriori model for PCI. These were 0.44 and 0.67, respectively, for the CTO a priori and a posteriori models, and 0.58 and 0.74, respectively, for the TAVI a priori and a posteriori models. Conclusion: A priori predictive models can help operators estimate the PSD before performing the intervention while a posteriori models are more accurate estimates and can be useful in the absence of skin dose mapping solutions

28 August 2025 in Radiation Protection Dosimetry
Verified
Journal Article
Closed access
JFJoëlle Ann Feghali
Joëlle Ann Feghali
JMJacques-Antoine Maisonobe
Jacques-Antoine Maisonobe
BGBouchra Habib Geryes
Bouchra Habib Geryes
Introduction: Surgical C-arms are essential tools in pediatric surgery in various specialties. The selection of an appropriate C-arm for pediatric use is critical, as manufacturers offer different balances between radiation dose and image quality. Objective: This study introduces a practical measurement protocol that enables straightforward comparison of C-arms using readily available tools in most facilities. Methods: A measurement protocol for evaluating radiation dose and image quality across different C-arm models for pediatric use is suggested. To illustrate this methodology, seven C-arm models from three manufacturers were assessed using a polymethyl methacrylate phantom to simulate pediatric patients. Dose and image quality were measured across various configurations, including fluoroscopy and low-dose modes, while considering features like additional copper filtration, anti-scatter grid removal, and field zoom. Results: Dose and image quality measurements on C-arms illustrate the methodology’s application and the impact of fluoroscopy parameters and pediatric-specific features on dose and image quality. Recommendations are provided to guide the selection and optimization of C-arms for pediatric surgery, ensuring the best compromise between dose reduction and diagnostic image quality. Conclusion: This study introduces a practical method for evaluating C-arms in pediatric settings, helping to improve equipment selection and optimize imaging protocols for safer pediatric imaging practices.