Xiangxin Li

Xiangxin Li

Auto-generated profile, based on publicly available information

Xiangxin Li

Shenzhen Institutes of Advanced Technology (SIAT), Chinese Academy of Sciences (CAS), Shenzhen, Guangdong, China

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2017 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
XLXiangxin Li
Xiangxin Li
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
XZXu Zhang
Xu Zhang
HWHui Wang
Hui Wang
PFPeng Fang
Peng Fang
GLGuanglin Li
Guanglin Li
Most of the modern motorized prostheses are controlled with the surface electromyography (sEMG) recorded on the residual muscles of amputated limbs. However, the residual muscles are usually limited, especially after above-elbow amputations, which would not provide enough sEMG for the control of prostheses with multiple degrees of freedom. Signal fusion is a possible approach to solve the problem of insufficient control commands, where some non-EMG signals are combined with sEMG signals to provide sufficient information for motion intension decoding. In this study, a motion-classification method that combines sEMG and electroencephalography (EEG) signals were proposed and investigated, in order to improve the control performance of upper-limb prostheses. Four transhumeral amputees without any form of neurological disease were recruited in the experiments. Five motion classes including hand-open, hand-close, wrist-pronation, wrist-supination, and no-movement were specified. During the motion performances, sEMG and EEG signals were simultaneously acquired from the skin surface and scalp of the amputees, respectively. The two types of signals were independently preprocessed and then combined as a parallel control input. Four time-domain features were extracted and fed into a classifier trained by the Linear Discriminant Analysis (LDA) algorithm for motion recognition. In addition, channel selections were performed by using the Sequential Forward Selection (SFS) algorithm to optimize the performance of the proposed method. The classification performance achieved by the fusion of sEMG and EEG signals was significantly better than that obtained by single signal source of either sEMG or EEG. An increment of more than 14% in classification accuracy was achieved when using a combination of 32-channel sEMG and 64-channel EEG. Furthermore, based on the SFS algorithm, two optimized electrode arrangements (10-channel sEMG + 10-channel EEG, 10-channel sEMG + 20-channel EEG) were obtained with classification accuracies of 84.2 and 87.0%, respectively, which were about 7.2 and 10% higher than the accuracy by using only 32-channel sEMG input. This study demonstrated the feasibility of fusing sEMG and EEG signals towards improving motion classification accuracy for above-elbow amputees, which might enhance the control performances of multifunctional myoelectric prostheses in clinical application. The study was approved by the ethics committee of Institutional Review Board of Shenzhen Institutes of Advanced Technology, and the reference number is SIAT-IRB-150515-H0077.

1 November 2017 in Computers in Biology and Medicine
Verified
Journal Article
Closed access
Oluwarotimi Williams SamuelOluwarotimi Williams Samuel
Oluwarotimi Williams Samuel
XLXiangxin Li
Xiangxin Li
YGYanjuan Geng
Yanjuan Geng
MAMojisola Grace Asogbon
Mojisola Grace Asogbon
PFPeng Fang
Peng Fang
GLGuanglin Li
Guanglin Li

29 August 2023 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YDYuanzhe Dong
Yuanzhe Dong
XTXi Tang
Xi Tang
QLQingge Li
Qingge Li
YWYingying Wang
Yingying Wang
NJNaifu Jiang
Naifu Jiang
PFPeng Fang
Peng Fang
Electroencephalogram (EEG) recordings often contain artifacts that would lower signal quality. Many efforts have been made to eliminate or at least minimize the artifacts, and most of them rely on visual inspection and manual operations, which is time/labor-consuming, subjective, and incompatible to filter massive EEG data in real-time. In this paper, we proposed a deep learning framework named Artifact Removal Wasserstein Generative Adversarial Network (AR-WGAN), where the well-trained model can decompose input EEG, detect and delete artifacts, and then reconstruct denoised signals within a short time. The proposed approach was systematically compared with commonly used denoising methods including Denoised AutoEncoder, Wiener Filter, and Empirical Mode Decomposition, with both public and self-collected datasets. The experimental results proved the promising performance of AR-WGAN on automatic artifact removal for massive data across subjects, with correlation coefficient up to 0.726±0.033, and temporal and spatial relative root-mean-square error as low as 0.176±0.046 and 0.761±0.046, respectively. This work may demonstrate the proposed AR-WGAN as a high-performance end-to-end method for EEG denoising, with many on-line applications in clinical EEG monitoring and brain-computer interfaces.

1 December 2023 in Journal of Neural Engineering
Verified
Journal Article
Open access
PDF file
YLYan Liu
Yan Liu
XPXinhao Peng
Xinhao Peng
YTYingxiao Tan
Yingxiao Tan
TOTolulope Tofunmi Oyemakinde
Tolulope Tofunmi Oyemakinde
MWMengtao Wang
Mengtao Wang
XLXiangxin Li
Xiangxin Li
Objective. Surface electromyography pattern recognition (sEMG-PR) is considered as a promising control method for human-machine interaction systems. However, the performance of a trained classifier would greatly degrade for novel users since sEMG signals are user-dependent and largely affected by a number of individual factors such as the quantity of subcutaneous fat and the skin impedance. Approach. To solve this issue, we proposed a novel unsupervised cross-individual motion recognition method that aligned sEMG features from different individuals by self-adaptive dimensional dynamic distribution adaptation (SD-DDA) in this study. In the method, both the distances of marginal and conditional distributions between source and target features were minimized through automatically selecting the optimal feature domain dimension by using a small amount of unlabeled target data. Main results. The effectiveness of the proposed method was tested on four different feature sets, and results showed that the average classification accuracy was improved by above 10% on our collected dataset with the best accuracy reached 90.4%. Compared to six kinds of classic transfer learning methods, the proposed method showed an outstanding performance with improvements of 3.2%-13.8%. Additionally, the proposed method achieved an approximate 9% improvement on a publicly available dataset. Significance. These results suggested that the proposed SD-DDA method is feasible for cross-individual motion intention recognition, which would provide help for the application of sEMG-PR based system.

2 April 2021 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
YWYingying Wang
Yingying Wang
Lelun JiangLelun Jiang
Lelun Jiang
LRLei Ren
Lei Ren
HPHuang Pingao
Huang Pingao
MYMei Yu
Mei Yu
GLGuanglin Li
Guanglin Li
Objective: Electrophysiological signals are recorded generally by metal electrodes placed on body surface. For long term use, the signal quality may decay with the change of interface impedance between electrodes and skin due to the conductive hydrogel dehydration. Besides, electrodes may shift during body movements, which causes unstable signal recordings. Methods: To improve the quality of electrophysiological signal recordings on human body surface, a type of microneedle electrode array (MEA) with microneedles around 550 μm in length was fabricated with a magnetization-induce self-assembly method. Results: Compared with the commonly used dry electrode array, the MEA has lower and more stable interface impedance, especially when the electrode-skin interface is under unstable pressures. For electrophysiological signal recording, the MEA can acquire electromyography (EMG) with significantly lower noise energy, higher signal-to-noise ratio, and higher motion-classification accuracy based on the EMG pattern-recognition method. Additionally, high quality electrocardiography (ECG) can be recorded by using the MEA, where more accurate R-peaks are extracted in different scenarios. Besides, there was no report about any discomfort like bleeding or inflammation by all the subjects. Conclusion: This research proved that the microneedles on the MEA can penetrate through the corneum and reach the epidermis of the subjects, which could avoid the influence of corneum and fix the electrode on the body surface for high-quality signal recording especially during body movements. Furthermore, the microneedles would not touch the dermis, enabling a painless signal acquisition. Significance: This work is beneficial to the applications of wearable human-machine interface technology.

2 March 2022 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
YWYingying Wang
Yingying Wang
PFPeng Fang
Peng Fang
XTXi Tang
Xi Tang
NJNaifu Jiang
Naifu Jiang
LTLan Tian
Lan Tian
GLGuanglin Li
Guanglin Li
Synergetic recovery of both somatosensory and motor functions is highly desired by limb amputees to fully regain their lost limb abilities. The commercially available prostheses can restore the lost motor function in amputees but lack intuitive sensory feedback. The previous studies showed that electrical stimulation on the arm stump would be a promising approach to induce sensory information into the nervous system, enabling the possibility of realizing sensory feedback in limb prostheses. However, there are currently limited studies on the effective evaluation of the sensations evoked by transcutaneous electrical nerve stimulation (TENS). In this paper, a multichannel TENS platform was developed and the different stimulus patterns were designed to evoke stable finger sensations for a transradial amputee. Electroencephalogram (EEG) was recorded simultaneously during TENS on the arm stump, which was utilized to evaluate the evoked sensations. The experimental results revealed that different types of sensations on three phantom fingers could be stably evoked for the amputee by properly selecting TENS patterns. The analysis of the event-related potential (ERP) of EEG recordings further confirmed the evoked sensations, and ERP latencies and curve characteristics for different phantom fingers showed significant differences. This work may provide insight for an in-depth understanding of how somatosensation could be restored in limb amputees and offer technical support for the applications of non-invasive sensory feedback systems.