Hao Yuan

Hao Yuan

Auto-generated profile, based on publicly available information

Hao Yuan

College of Electrical Engineering, Sichuan University, Chengdu, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 December 2021 in High Voltage
Verified
Journal Article
Open access
PDF file
ZLZerui Li
Zerui Li
KZKai Zhou
Kai Zhou
PMPengfei Meng
Pengfei Meng
HYHao Yuan
Hao Yuan
ZWZikang Wang
Zikang Wang
GZGuangya Zhu
Guangya Zhu
Silicone grease (SG) is used for lubrication during cable accessory installation and can penetrate into the silicone rubber (SiR), leading to properties deterioration of the SiR. In this study, the effects of SG on the breakdown characteristics of the cross‐linked polyethylene (XLPE)–SiR interface are investigated. First, the variation of the XLPE–SiR interface breakdown voltage with SG coating time is experimentally explored. The interface breakdown voltage significantly increases after SG is applied, remains stable for coating times of up to approximately 144 h and then rapidly decreases; the minimum interface breakdown voltage is lower than that without the SG coating. Next, the effects of SG on the chemical composition and surface topography of the SiR are examined by infrared spectroscopy and optical profilometry, respectively. The SG penetration does not change the functional groups of the SiR but significantly increases its surface roughness. Finally, the interface electric‐field distribution after coating with SG is analysed by finite‐element simulation, revealing that the residual SG at the interface distorts the interface electric field after a long coating time. The increase in the SiR surface roughness caused by SG diffusion and the interface electric‐field distortion caused by the residual SG together lead to the decrease of the interface breakdown voltage.

29 April 2022 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KZKai Zhou
Kai Zhou
HYHao Yuan
Hao Yuan
Yuan LiYuan Li
Yuan Li
MLMingzhi Li
Mingzhi Li
ZLZerui Li
Zerui Li
SLSiyan Lin
Siyan Lin
The polarization and depolarization current (PDC) measurement has been widely used to assess the aging degree of cross-linked polyethylene (XLPE) cables. However, the aging type identification of XLPE cables has not been fully considered. In this study we conduct PDC measurement on thermal-aged and water tree-aged XLPE cable samples respectively, upon which a graphical approach to assess the insulation condition and distinguish the aging type of XLPE cables is proposed. First, to designate the evaluation indexes of the insulation condition, multiple PDC measurement based dielectric parameters are considered. Then, to reflect the sensitivity of each evaluation index to the condition of XLPE cable, a combined weighting method based on the group fuzzy analytic hierarchy process (GFAHP) and entropy method (EM) is introduced. Furthermore, the improved radar chart method (RCM) based graphical approach is proposed to comprehensively and intuitively characterize the evaluation indexes. Finally, the aging degree of the XLPE cable samples is quantitatively assessed by calculating the area of the polygon in the chart. Simultaneously, utilizing the position of the areal coordinate and the shape characteristic parameter of the polygon, the thermal-aged and water tree-aged samples are effectively distinguished.

1 July 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
ZLZerui Li
Zerui Li
KZKai Zhou
Kai Zhou
CWChunpo Wang
Chunpo Wang
PMPengfei Meng
Pengfei Meng
Yuan LiYuan Li
Yuan Li
HYHao Yuan
Hao Yuan
Moisture at the insulation interface is the main cause for electrical breakdown and insulation failure of cable accessories. However, it is still unclear how the presence of moisture affects the discharge development and interfacial breakdown process. This paper clarifies the reasons for the breakdown failure of cable accessory insulation interfaces under the effect of moisture. First, the moisture and breakdown characteristics of faulty cable accessories in the field are presented. Second, the discharge evolution characteristics during the breakdown process of dry and wet interfaces are experimentally described. Then, the effect mechanism of moisture on the development of interfacial breakdown is explained by combining product analysis and electric field analysis. Finally, the proposed breakdown mechanism of insulation interface under the effect of moisture are verified through a field case. The experiment results show that the discharge develops in stages and generates gases during the breakdown of the insulation interface, and there exist multiple discrete arc discharges with random paths during the breakdown of the wet interface. The severe electric-field distortion and its dynamic movement caused by the gas bubble areas formed in the wet interface are the main reasons for the increase in randomness of interface discharge and the decrease in breakdown strength. Through current impulse detection and generated gas analysis, it is expected to provide new solutions for early fault detection for cable accessories.

18 September 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Yuan LiYuan Li
Yuan Li
SYSenhong Yang
Senhong Yang
RLRanran Li
Ranran Li
HYHao Yuan
Hao Yuan
KZKai Zhou
Kai Zhou
Shakeel AkramShakeel Akram
Shakeel Akram
For oil-immersed power equipment, the accumulation of cellulose impurities in oil-paper insulation poses a significant problem. To address this issue, this study investigates the migration and bridging characteristics of cellulose impurities in oil-paper insulation under DC voltage. A kinetic analysis model is developed to simulate the impurity trajectories and quantitative analysis of speed, offset distance, and other parameters of cellulose impurities. The results indicate the motion cycle of cellulose impurity under the slightly uneven DC electric field consists of lifting, upward, and downward stages, with a maximum speed of over 10 2 mm/s and maximum acceleration of over 10 2 m/s 2 . During the lifting stage, particle velocity grows quickly and then slows, while during the downward stage velocity increases sharply to a maximum and then gradually decreases. The horizontal offset distance decreases with increased motion cycles. The cellulose impurities departed from the sphere electrode and the insulating paper surface migrate in opposite directions along their respective trajectories. As they gradually approach each other, these impurities undergo collisions and exchange charges, and eventually form a heap-like bridge. Results of this study can guide the development of better insulation materials for high-voltage electrical equipment and aid in the removal of impurities.

1 October 2021 in Polymer Testing
Verified
Journal Article
Open access
KZKai Zhou
Kai Zhou
HYHao Yuan
Hao Yuan
Shakeel AkramShakeel Akram
Shakeel Akram
PMPengfei Meng
Pengfei Meng
AMAtif Mahmood
Atif Mahmood
MIM. Imran
M. Imran

26 July 2023 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
HYHao Yuan
Hao Yuan
Yuan LiYuan Li
Yuan Li
KZKai Zhou
Kai Zhou
HZHao Zhou
Hao Zhou
The silicone oil (SO)-silicone rubber (SiR) biphasic dielectric composite serves as irreplaceable internal insulation structure in fluid-filled cable terminations. Moisture ingress is universally acknowledged as the main factor causing internal insulation degradation and subsequent failure of terminations. However, there is little knowledge on moisture transfer in SO-SiR systems, especially when taking swelling effect into consideration, which restricts deeper understanding for the failure mechanism of the termination insulation. In this work, the moisture transfer characteristics in SO-SiR are investigated by measuring the moisture content of SO and SiR during immersion with different moisture content levels at different temperature levels. When the initial moisture content of SO is below ~40 ppm, water transfers from SiR to SO, and the opposite transfer direction occurs at higher moisture levels. The rise of temperature facilitates moisture transfer and results in more moisture content in SO and less in SiR at equilibrium. Moreover, experiments to determine the swelling degree of SO-SiR are performed, and the results and model analysis indicated that the swelling is a Langmuir-type diffusion process. It is found that the time to reach moisture equilibrium lags behind that to reach swelling equilibrium in SO-SiR. On this basis, further analysis concludes the moisture transfer process under swelling effect into three stages from the beginning of immersion to equilibrium, and reveals the mechanism behind it. Finally, moisture equilibrium curves for SO-SiR system are presented.