17 November 2003 in Astronomy & Astrophysics
SPI is a high spectral resolution gamma-ray telescope on board the ESA mission INTEGRAL (International Gamma Ray Astrophysics Laboratory). It consists of an array of 19 closely packed germanium detectors surrounded by an active anticoincidence shield of BGO. The imaging capabilities of the instrument are obtained with a tungsten coded aperture mask located 1.7 m from the Ge array. The fully coded field-of-view is , the partially coded field of view amounts to , and the angular resolution is . The energy range extends from 20 keV to 8 MeV with a typical energy resolution of 2.5 keV at 1.3 MeV. Here we present the general concept of the instrument followed by a brief description of each of the main subsystems. INTEGRAL was successfully launched in October 2002 and SPI is functioning extremely well.
17 November 2003 in Astronomy & Astrophysics
The SPI instrument has been launched on-board the INTEGRAL observatory on October 17, 2002. SPI is a spectrometer devoted to the sky observation in the 20 keV–8 MeV energy range using 19 germanium detectors. The performance of the cryogenic system is nominal and allows to cool the 19 kg of germanium down to 85 K with a comfortable margin. The energy resolution of the whole camera is 2.5 keV at 1.1 MeV. This resolution degrades with time due to particle irradiation in space. We show that the annealing process allows the recovery of the initial performance. The anticoincidence shield works as expected, with a low threshold at 75 keV, reducing the GeD background by a factor of 20. The digital front-end electronics system allows the perfect alignement in time of all the signals as well as the optimisation of the dead time (12%). We demonstrate that SPI is able to map regions as complex as the galactic plane. The obtained spectrum of the Crab nebula validates the present version of our response matrix. The 3σ sensitivity of the instrument at 1 MeV is ph cm-2 s-1 keV-1 for the continuum and ph cm-2 s-1 for narrow lines.
15 August 2012 in Medical Physics
25 July 2005 in IEEE Transactions on Nuclear Science
We have studied a new and inexpensive method of measuring the depth of interaction (DOI) in /spl gamma/-ray detectors with large-sized scintillation crystals. This method takes advantage of the strong correlation between the width of the undisturbed light-distribution in continuous crystals and the /spl gamma/-ray's DOI. In order to quantify the dependence of the distribution's width with respect to the DOI, we first studied an analytical model of the light-distribution and tested it by means of Monte Carlo (MC) simulations of the light transport inside the crystal. Further we present an inexpensive modification of the commonly used charge division circuit that allows analog and instantaneous computation of the light-distribution's second moment without affecting the determination of the centroid. This redesigned resistor network is based on the position-sensitive proportional counter (DPC) readout and allows, together with position sensitive photo-detectors, the additional measurement of the light-distribution's standard-deviation /spl sigma/. We tested the proposed circuit using the design-tool OrCAD and found the signal sufficiently large for digitalization. Finally, we conducted MC simulations of a realistic Positron Emission Tomography (PET) detector module setup that mimic a continuous Lu/sub 2/SiO/sub 5/:Ce/sup 3+/ (LSO) crystal of dimensions 40/spl times/40/spl times/10 mm/sup 3/ together with the new large area position-sensitive photo multiplier tube (PSPMT) H8500 from Hamamatsu. The influence of Compton scattering on the DOI determination was also estimated by MC simulations. Altogether, we obtained /spl les/ 5 mm DOI resolution. PACS: 87.57.Ce, 87.58.Fg, 87.62.+n, 07.85.-m.
15 April 2013 in Medical Physics
13 June 2018 in IEEE Transactions on Radiation and Plasma Medical Sciences
In this review, we will cover both clinical and technical aspects of the advantages and disadvantages of organ specific (dedicated) molecular imaging (MI) systems, namely positron emission tomography (PET) and single photon emission computed tomography, including gamma cameras. This review will start with the introduction to the organ-dedicated MI systems. Thereafter, we will describe the differences and their advantages/disadvantages when compared with the standard large size scanners. We will review time evolution of dedicated systems, from first attempts to current scanners, and the ones that ended in clinical use. We will review later the state of the art of these systems for different organs, namely: breast, brain, heart, and prostate. We will also present the advantages offered by these systems as a function of the special application or field, such as in surgery, therapy assistance and assessment, etc. Their technological evolution will be introduced for each organ-based imager. Some of the advantages of dedicated devices are: higher sensitivity by placing the detectors closer to the organ, improved spatial resolution, better image contrast recovery (by reducing the noise from other organs), and also lower cost. Designing a complete ring-shaped dedicated PET scanner is sometimes difficult and limited angle tomography systems are preferable as they have more flexibility in placing the detectors around the body/organ. Examples of these geometries will be presented for breast, prostate and heart imaging. Recently achievable excellent time of flight capabilities below 300-ps full width at half of the maximum reduce significantly the impact of missing angles on the reconstructed images.