1 November 2016 in Journal of Shoulder and Elbow Surgery
1 August 2014 in Clinical Orthopaedics and Related Research
Recurrent shoulder instability is commonly associated with Hill-Sachs defects. These defects may engage the glenoid rim, contributing to glenohumeral dislocation. Two treatment options to manage engaging Hill-Sachs defects are the remplissage procedure, which fills the defect with soft tissue, and the Latarjet procedure, which increases glenoid arc length. Little evidence exists to support one over the other. We performed a biomechanical comparison of the remplissage procedure to the traditional Latarjet coracoid transfer for management of engaging Hill-Sachs defects in terms of joint stiffness (resistance to anterior translation), ROM, and frequency of dislocation. Eight cadaveric specimens were tested on a shoulder instability simulator. Testing was performed with a 25% Hill-Sachs defect with an intact glenoid and after remplissage and Latarjet procedures. Joint stiffness, internal-external rotation ROM, and frequency of dislocation were assessed. Additionally, horizontal extension ROM was measured in composite glenohumeral abduction. After remplissage, stiffness increased in adduction with neutral rotation (12.7 ± 3.7 N/mm) relative to the Hill-Sachs defect state (8.7 ± 3.3 N/mm; p = 0.016). The Latarjet procedure did not affect joint stiffness (p = 1.0). Internal-external rotation ROM was reduced in abduction after the Latarjet procedure (49° ± 14°) compared with the Hill-Sachs defect state (69° ± 17°) (p = 0.009). Horizontal extension was reduced after remplissage (16° ± 12°) relative to the Hill-Sachs defect state (34° ± 8°) (p = 0.038). With the numbers available, there was no difference between the procedures in terms of the frequency of dislocation after reconstruction: 84% of specimens (27 of 32 testing scenarios) stabilized after remplissage, while 94% of specimens (30 of 32 testing scenarios) stabilized after the Latarjet procedure. Both procedures proved effective in reducing the frequency of dislocation in a 25% Hill-Sachs defect model, while neither procedure consistently altered joint stiffness. In the treatment of shoulder instability with a humeral head bone defect and an intact glenoid rim, this study supports the use of both the remplissage and Latarjet procedures. Clinical studies and larger cadaveric studies powered to detect differences in instability rates are needed to evaluate these procedures in terms of their comparative efficacy at preventing dislocation, as any differences between them seem likely to be small.
1 April 2011 in Journal of Biomechanics
1 March 2021 in Journal of Shoulder and Elbow Surgery
1 April 2020 in Journal of Shoulder and Elbow Surgery
1 June 2014 in Journal of Orthopaedic Trauma
Background: The effect of radial head implant length on forearm biomechanics is not well understood. This study examined the influence of an increase or a decrease in radial head implant length on forearm load transfer as measured by interosseous membrane (IOM) tension and changes in radiocapitellar joint contact properties. Methods: An upper extremity simulator was used to examine 6 cadaveric specimens with 5 different radial head implant lengths (−4 mm, −2 mm, anatomically correct, +2 mm, and +4 mm). A load-sensing device was woven into the fibers of IOM to quantify its tension. An interpositional pressure measurement sensor was used to determine radiocapitellar joint contact area and pressure. Axial loads of 160 N were applied to the forearm through active pronation and supination with the elbow fixed at 90 degrees of flexion. Results: Increasing radial head implant length by 4 mm unloaded the IOM in all cases. Decreasing implant length by 4 mm significantly increased the IOM tension (P = 0.005). No significant differences were found in IOM tension between the correct head implant length and the −2 mm implant (P = 0.29). Contact pressure significantly increased with increasing radial head implant length (P = 0.021) and contact area diminished with both an increase and a decrease in radial head implant length, but this was not statistically significant (P = 0.051). Conclusions: Increasing radial head implant length decreased IOM tension and increased radiocapitellar joint contact pressure. Clinical Relevance: These findings illustrate the importance of precise restoration of radial length when performing a radial head replacement. If the native radial head length is difficult to accurately assess, avoid increasing the length of the radial head to prevent detrimental changes in the biomechanics of the forearm and the potential for clinically important radiocapitellar joint pathology.