Four different cooling options for three-phase concentric medium-voltage HTS cables have been investigated. These four cooling options differ in the feed-in and return of the liquid nitrogen and in the utilization or non-utilization of an annular gap cooling and are so determining the whole cable design. Simulations of pressure drops and temperature profiles have been carried out to evaluate the construction limits and the efficiency of each design. The simulation results provide the maximum transmission lengths and minimal cable diameters for a given transmission power and a defined cable operation range. The results indicate that a design without annular gap cooling can lead to a compact cable design and a high transmission length at the same time.
13 August 2020 in IEEE Transactions on Applied Superconductivity
This paper presents a theoretical investigation of a Resistive Superconducting Fault Current Limiter (R-SFCL) operating in a medium-voltage network. The considered power system presents a high level of fault current as well as a high transient recovery voltage. The simulation result shows that the R-SFCL not only limits the fault current to a desirable value, but also improves transient recovery voltage of circuit breakers by eliminating high-harmonics order generated by the opening of the circuit breaker.
1 January 2018 in Physica C: Superconductivity and its Applications
This work presents simulations of stationary and transient (fault condition) regimes for a three-phase concentric HTS cable with and without a standalone Superconducting Fault Current Limiter (SFCL). The stationary study carried out previously to the transient analysis verifies the viability of the proposed cable de-sign. The response of the HTS cable to fault currents by varying the thickness of copper stabilization layers is analyzed. As an option a SFCL is supposed to be connected in series to the same HTS cable to investigate if and how a SFCL device could protect the HTS cable as well as the power network. Results show that fault currents can be limited by adapting the copper layer thickness of the HTS tapes in the cable but this may result in too high temperatures in the coolant. Only a carefully designed SFCL device can prevent longer cable outages or even damages in the HTS cable caused by too high temperatures.
5 June 2023 in IEEE Open Journal of Power Electronics
Power Hardware-in-the-Loop (PHIL) facilitates the testing of novel power engineering solutions in the lab, allowing a flexible testing environment while keeping the high testing fidelity of real hardware. Due to the analog/digital intersection of the PHIL setup, selecting simply continuous or single-rate discrete-time domain fails to model such a hybrid system accurately. This paper proposes a multi-rate discrete-time modeling approach of a PHIL setup that can estimate the mixed analog and digital nature of the PHIL accurately, resulting in accuracy improvement over a wide range of frequencies. The proposed approach applies two different sampling times, a large one connected to the digital simulator and a small one for modeling the analog-hardware part. Dynamics and delays of interfaces, such as analog-to-digital converters, the power amplifier, the sensor, and the low-pass filter, have been accurately modeled and validated by means of experimental results.
2 April 2021 in IEEE Transactions on Applied Superconductivity
This study conducts a life-cycle assessment for the use of super-conducting medium voltage cables based on the AmpaCity cable in Germany. The results are compared with the use of a conven-tional high voltage cable. For the conventional cable, additional transformer losses are included, while for the superconducting cable the operation of the necessary cooling system is considered. The annual transmitted energy represents the functional unit. The annual loss energy of the HTS cable system is lower than that of conventional cable from a load factor of ma = 0.43. This load factor also represents the ecological break-even point. For a load factor of ma 0.43, the greenhouse gas emissions and cumu-lative energy demand of the superconducting cable system are lower than those of the conventional cable system. Thus, if the load is sufficiently high, a superconducting cable can thus be a more environmentally friendly alternative for a future energy sys-tem.