Power systems face growing challenges of voltage instability, line congestion, and increased losses under rising demand. This study proposes a coordinated approach using two flexible AC transmission system (FACTS) devices: the static var compensator (SVC) and the thyristor controlled series capacitor (TCSC), together with photovoltaic (PV) generation, to enhance grid performance. The IEEE 30 bus test system is analyzed under normal and increased load conditions (5%, 10%, 15% load growth). Results show that coordinated SVC TCSC operation improves voltage profiles, reduces critical line loading by 14%, and lowers active and reactive losses by 10% and 23.8%, respectively, in the base case. Under a 15% load increase, integrating a 25 MW PV system with the coordinated FACTS restores the minimum voltage to 0.95 p.u., reduces line congestion by 27%, and decreases active and reactive losses by 35.5% and 53.5%. The combined FACTS PV strategy proves essential for maintaining stability and efficiency under high load growth. This integrated approach provides practical guidance for transmission operators toward resilient, loss aware, and renewable integrated smart grids.
1 March 2026 in International Journal of Power Electronics and Drive Systems (IJPEDS)
This paper presents a comprehensive comparative study of proportional-integral-derivative (PID) controller tuning methodologies for inductive load applications across three representative scenarios. We systematically evaluate classical methods (Ziegler-Nichols, internal model control) against global optimization algorithms (genetic algorithm (GA), particle swarm optimization (PSO)) applied to resistor-resistor-inductor (RRL) circuit models. Results demonstrate that PSO achieves superior performance for moderate-to-slow systems, reducing settling time by 84% while completely eliminating overshoot compared to Ziegler-Nichols. The algorithm automatically discovers optimal PI controller structures, simplifying implementation. However, for ultra-fast systems (time constants < 1 ms), internal model control proves more reliable, achieving 0.84 ms settling with only 0.16% overshoot. Optimized controllers demonstrate exceptional robustness, maintaining stability under ±50% parameter variations and effectively rejecting disturbances. This research provides engineers with a scenario-based framework for method selection, moving beyond heuristic tuning to achieve previously unattainable performance levels. The findings establish optimization-based tuning as a systematic, reliable approach for high-performance control system design in industrial applications.
1 September 2026 in International Journal of Power Electronics and Drive Systems (IJPEDS)
Failures and guaranteed dependability of the electrical grid, early fault diagnosis in power transformers is essential. By examining gas ratios suggestive of faults, dissolved gas analysis (DGA) continues to be a vital component for transformer health monitoring. Using four preprocessing techniques raw data, min-max normalization, logarithmic transformation, and square root transformation; this study suggests a machine learning method for fault detection using DGA gas ratios (such as CH₄/H₂, C₂H₂/C₂H₄). Random forest (RF), support vector machines (SVM), gradient boosted trees (GBT), and a hybrid RF-GBT model that uses prediction fusion were the four supervised classifiers assessed. Performance was assessed using accuracy, precision, recall, f1-score, and Cohen's kappa. Experimental results show that the hybrid RF-GBT model with logarithmic transformation achieves the highest performance, with 94.93% accuracy and 92.37% Cohen's kappa, significantly outperforming individual classifiers. Data preprocessing, particularly logarithmic and square root transformations, enhances diagnostic robustness by mitigating feature skewness. This study underscores the importance of tailored preprocessing and ensemble methods for reliable transformer fault diagnosis.