Abigail Waldron

Abigail Waldron

Auto-generated profile, based on publicly available information

Abigail Waldron

Savannah River National Laboratory, South Carolina, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 June 2023 in The Analyst
Verified
Journal Article
Closed access
PDF file
BNBenjamin E. Naes
Benjamin E. Naes
SSSpencer Scott
Spencer Scott
AWAbigail Waldron
Abigail Waldron
SLSeth Lawson
Seth Lawson
MBMichael G. Bronikowski
Michael G. Bronikowski
MWMatthew Wellons
Matthew Wellons
The THermally Evaporated Spray for Engineered Uniform particulateS (THESEUS) production platform was developed to generate highly uniform mixed actinide oxide particles. The particulate synthesis platform builds on previous efforts and utilizes an aerosol-based technology to generate, calcine, characterize, and aggregate a monodisperse oxide phase particle product. In this study, particles comprised of uranium oxide, incorporated with varying compositions of thorium, were produced. Th/U test materials with 232Th concentrations between 1 ppm and 10%, ratioed to 238U, were successfully generated with in situ calcination at 600 °C and characterized by in situ aerodynamic particle size spectrometry and ex situ microanalytical methods. Populations of monodisperse particulates (geometric standard deviation – GSD < 1.15) with an average diameter near 1 μm were generatated and micro-Raman spectroscopy of individual particles identified U3O8 as the primary material phase for the range of Th/U samples analyzed. Single particle measurements and automated particle analyses by secondary ion mass spectrometry (SIMS) were performed. Uniform inter-particle elemental and isotopic homogeneity for uranium and thorium isotopes was characterized by SIMS, and a 232Th/238U relative sensitivity factor of 0.53 was determined. SIMS results demonstrated differences in the 232Th/238U profiling behavior for Th/U particulates with increased Th content (>1%). Despite the observed profiling behavior, single particle measurements of the 10% Th sample indicate inter-particle homogeneity. This work represents the first systematic study of Th/U microparticulate reference materials generated and intended for nuclear safeguards applications and serves as a demonstration of THESEUS to support a sustained capability for the production mixed-element particulate reference materials.

1 May 2021 in Spectrochimica Acta Part B: Atomic Spectroscopy
Verified
Journal Article
Closed access
KFK. Alicia Strange Fessler
K. Alicia Strange Fessler
AWAbigail Waldron
Abigail Waldron
ACArelis Colón
Arelis Colón
JCJ. Chance Carter
J. Chance Carter
SAS. Michael Angel
S. Michael Angel

4 October 2019 in Applied Spectroscopy
Verified
Journal Article
Open access
PDF file
JOJoshua M. Ottaway
Joshua M. Ottaway
AAAshley Allen
Ashley Allen
AWAbigail Waldron
Abigail Waldron
PPPhillip H. Paul
Phillip H. Paul
SAS. Michael Angel
S. Michael Angel
JCJ. Chance Carter
J. Chance Carter
A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

1 December 2017 in AKCE International Journal of Graphs and Combinatorics
Verified
Journal Article
Open access
RVRoger Vargas
Roger Vargas
AWAbigail Waldron
Abigail Waldron
ASAnika Sharma
Anika Sharma
RFRigoberto Flórez
Rigoberto Flórez
DNDarren Narayan
Darren Narayan
In 2010, Joyce et al. defined the leverage centrality of vertices in a graph as a means to analyze functional connections within the human brain. In this metric a degree of a vertex is compared to ...

7 August 2020 in Applied Spectroscopy
Verified
Journal Article
Closed access
PDF file
AAAshley Allen
Ashley Allen
AWAbigail Waldron
Abigail Waldron
JOJoshua M. Ottaway
Joshua M. Ottaway
JCJ. Chance Carter
J. Chance Carter
SAS. Michael Angel
S. Michael Angel
A new hyperspectral Raman imaging technique is described using a spatial heterodyne Raman spectrometer (SHRS) and a microlens array (MLA). The new technique enables the simultaneous acquisition of Raman spectra over a wide spectral range at spatially isolated locations within two spatial dimensions ( x, y) using a single exposure on a charge-coupled device (CCD) or other detector types such as a complementary metal-oxide semiconductor (CMOS) detector. In the SHRS system described here, a 4 × 4 mm MLA with 1600, 100 µm diameter lenslets is used to image the sample, with each lenslet illuminating a different region of the SHRS diffraction gratings and forming independent fringe images on the CCD. The fringe images from each lenslet contain the fully encoded Raman spectrum of the region of the sample “seen” by the lenslet. Since the SHRS requires no moving parts, all fringe images can be measured simultaneously with a single detector exposure, and in principle using a single laser shot, in the case of a pulsed laser. In this proof of concept paper, hyperspectral Raman spectra of a wide variety of heterogeneous samples are used to characterize the technique in terms of spatial and spectral resolution tradeoffs. It is shown that the spatial resolution is a function of the diameter of the MLA lenslets, while the number of spatial elements that can be resolved is equal to the number of MLA lenslets that can be imaged onto the SHRS detector. The spectral resolution depends on the spatial resolution desired, and the number of grooves illuminated on both diffraction gratings by each lenslet, or combination of lenslets in cases where they are grouped.

16 October 2026 in Rapid Communications in Mass Spectrometry
Verified
Journal Article
Closed access
AMAmie C. McElroy
Amie C. McElroy
AWAbigail M. Waldron
Abigail M. Waldron
ACAustin L. Coleman
Austin L. Coleman
CGCaroline O. Granger
Caroline O. Granger
SDSteven Demers
Steven Demers
JMJoseph M. Mannion
Joseph M. Mannion