J. Chance Carter

J. Chance Carter

Auto-generated profile, based on publicly available information

J. Chance Carter

Lawrence Livermore National Laboratory

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2005 in Applied Spectroscopy
Verified
Journal Article
Open access
JCJ. Chance Carter
J. Chance Carter
SAS. Michael Angel
S. Michael Angel
MLMarion Lawrence-Snyder
Marion Lawrence-Snyder
JSJon Scaffidi
Jon Scaffidi
RWRichard E. Whipple
Richard E. Whipple
JRJohn G. Reynolds
John G. Reynolds
We have designed and demonstrated a standoff Raman system for detecting high explosive materials at distances up to 50 meters in ambient light conditions. In the system, light is collected using an 8-in. Schmidt–Cassegrain telescope fiber-coupled to an f/1.8 spectrograph with a gated intensified charge-coupled device (ICCD) detector. A frequency-doubled Nd: YAG (532 nm) pulsed (10 Hz) laser is used as the excitation source for measuring remote spectra of samples containing up to 8% explosive materials. The explosives RDX, TNT, and PETN as well as nitrate- and chlorate-containing materials were used to evaluate the performance of the system with samples placed at distances of 27 and 50 meters. Laser power studies were performed to determine the effects of laser heating and photodegradation on the samples. Raman signal levels were found to increase linearly with increasing laser energy up to ∼3 × 10 6 W/cm 2 for all samples except TNT, which showed some evidence of photo- or thermal degradation at higher laser power densities. Detector gate width studies showed that Raman spectra could be acquired in high levels of ambient light using a 10 microsecond gate width.

1 January 2006 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
JCJ. Chance Carter
J. Chance Carter
RARosa M. Alvis
Rosa M. Alvis
SBSteve B. Brown
Steve B. Brown
KLKevin C. Langry
Kevin C. Langry
TWThomas S. Wilson
Thomas S. Wilson
BCBill W. Colston
Bill W. Colston

30 November 2021 in Molecules
Verified
Journal Article
Open access
PDF file
WGWilliam E Gilbraith
William E Gilbraith
JCJ. Chance Carter
J. Chance Carter
KAKristl L. Adams
Kristl L. Adams
KBKarl Booksh
Karl Booksh
JOJoshua Ottaway
Joshua Ottaway
We present four unique prediction techniques, combined with multiple data pre-processing methods, utilizing a wide range of both oil types and oil peroxide values (PV) as well as incorporating natural aging for peroxide creation. Samples were PV assayed using a standard starch titration method, AOCS Method Cd 8-53, and used as a verified reference method for PV determination. Near-infrared (NIR) spectra were collected from each sample in two unique optical pathlengths (OPLs), 2 and 24 mm, then fused into a third distinct set. All three sets were used in partial least squares (PLS) regression, ridge regression, LASSO regression, and elastic net regression model calculation. While no individual regression model was established as the best, global models for each regression type and pre-processing method show good agreement between all regression types when performed in their optimal scenarios. Furthermore, small spectral window size boxcar averaging shows prediction accuracy improvements for edible oil PVs. Best-performing models for each regression type are: PLS regression, 25 point boxcar window fused OPL spectral information RMSEP = 2.50; ridge regression, 5 point boxcar window, 24 mm OPL, RMSEP = 2.20; LASSO raw spectral information, 24 mm OPL, RMSEP = 1.80; and elastic net, 10 point boxcar window, 24 mm OPL, RMSEP = 1.91. The results show promising advancements in the development of a full global model for PV determination of edible oils.

22 August 2017 in ACS Sensors
Verified
Journal Article
Open access
ETErhan Tütüncü
Erhan Tütüncü
VKVjekoslav Kokoric
Vjekoslav Kokoric
AWAndreas Wilk
Andreas Wilk
FSFelicia Seichter
Felicia Seichter
MSMichael Schmid
Michael Schmid
BMBoris Mizaikoff
Boris Mizaikoff
In this study, an innovative approach based on fiberoptically coupled substrate-integrated hollow waveguide (iHWG) gas cells for the analysis of low sample volumes suitable for remote broad- and narrow-band mid-infrared (MIR; 2.5–20 μm) sensing applications is reported. The feasibility of remotely addressing iHWG gas cells, configured in a double-pass geometry via a reflector, by direct coupling to a 7-around-1 mid-infrared fiber bundle is demonstrated, facilitating low-level hydrocarbon gas analysis. For comparison studies, two iHWGs with substrate dimensions of 50 × 50 × 12 mm (L × W × H) and geometric channel lengths of 138 and 58.5 mm, serving as miniature light-guiding gas cells, were fiber-coupled to a Fourier transform infrared spectrometer enabling broadband MIR sensing. In addition to the fundamental feasibility of this concept, the achievable sensitivity toward several gaseous hydrocarbons and the reproducibility of assembling the fiber-iHWG interface were investigated.

8 April 2021 in Applied Spectroscopy
Verified
Journal Article
Closed access
PDF file
JOJoshua M. Ottaway
Joshua M. Ottaway
JCJ. Chance Carter
J. Chance Carter
KAKristl L. Adams
Kristl L. Adams
JCJoseph Camancho
Joseph Camancho
Barry LavineBarry Lavine
Barry Lavine
KBKarl Booksh
Karl Booksh
The peroxide value of edible oils is a measure of the degree of oxidation, which directly relates to the freshness of the oil sample. Several studies previously reported in the literature have paired various spectroscopic techniques with multivariate analyses to rapidly determine peroxide values using field portable and process instrumentation; those efforts presented “best-case scenarios” with oils from narrowly defined training and test sets. The purpose of this paper is to evaluate the use of near- and mid-infrared absorption and Raman scattering spectroscopies on oil samples from different oil classes, including seasonal and vendor variations, to determine which measurement technique or combination thereof is best for predicting peroxide values. Following peroxide value assays of each oil class using an established titration-based method, global and global-subset calibration models were constructed from spectroscopic data collected on the 19 oil classes used in this study. Spectra from each optical technique were used to create partial least squares regression calibration models to predict the peroxide value of unknown oil samples. A global peroxide value model based on near-infrared (8 mm optical path length) oil measurements produced the lowest RMSEP (4.9), followed by 24 mm optical path length near infrared (5.1), Raman (6.9) and 50 µm optical path length mid-infrared (7.3). However, it was determined that the Raman RMSEP resulted from chance correlations. Global peroxide value models based on low-level fusion of the NIR (8 and 24 mm optical path length) data and all infrared data produced the same RMSEP of 5.1. Global subset models, based on any of the spectroscopies and olive oil training sets from any class (pure, extra light, extra virgin), all failed to extrapolate to the non-olive oils. However, the near-infrared global subset model built on extra virgin olive oil could extrapolate to test samples from other olive oil classes. This work demonstrates the difficulty of developing a truly global method for determining peroxide value of oils.

27 August 2020 in Applied Spectroscopy
Verified
Journal Article
Open access
PDF file
AWAbigail Waldron
Abigail Waldron
AAAshley Allen
Ashley Allen
ACArelis Colón
Arelis Colón
JCJ. Chance Carter
J. Chance Carter
SAS. Michael Angel
S. Michael Angel
A monolithic spatial heterodyne Raman spectrometer (mSHRS) is described, where the optical components of the spectrometer are bonded to make a small, stable, one-piece structure. This builds on previous work, where we described bench top spatial heterodyne Raman spectrometers (SHRS), developed for planetary spacecraft and rovers. The SHRS is based on a fixed grating spatial heterodyne spectrometer (SHS) that offers high spectral resolution and high light throughput in a small footprint. The resolution of the SHS is not dependent on a slit, and high resolution can be realized without using long focal length dispersing optics since it is not a dispersive device. Thus, the SHS can be used as a component in a compact Raman spectrometer with high spectral resolution and a large spectral range using a standard 1024 element charge-coupled device. Since the resolution of the SHRS is not dependent on a long optical path, it is amenable to the use of monolithic construction techniques to make a compact and robust device. In this paper, we describe the use of two different monolithic SHSs (mSHSs), with Littrow wavelengths of 531.6 nm and 541.05 nm, each about 3.5 × 3.5 × 2.5 cm in size and weighing about 80 g, in a Raman spectrometer that provides ∼3500 cm −1 spectral range with 4–5 cm −1 and 8–9 cm −1 resolution, for 600 grooves/mm and 150 grooves/mm grating-based mSHS devices, respectively. In this proof of concept paper, the stability, spectral resolution, spectral range, and signal-to-noise ratio of the mSHRS spectrometers are compared to our bench top SHRS that uses free-standing optics, and signal to noise comparisons are also made to a Kaiser Holospec f/1.8 Raman spectrometer.