Heike Vogelsang

Heike Vogelsang

Auto-generated profile, based on publicly available information

Heike Vogelsang

Department of Anesthesiology Ruhr‐University Bochum St. Josef‐ and St. Elisabeth‐Hospital Bochum Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Minerva Anestesiologica
Verified
Journal Article
Closed access
JHJennifer Herzog-Niescery
Jennifer Herzog-Niescery
HVHeike Vogelsang
Heike Vogelsang
PGPhilipp Gude
Philipp Gude
HSHans-Martin Seipp
Hans-Martin Seipp
HBHorst Bartz
Horst Bartz
MBMartin Bellgardt
Martin Bellgardt
Article: The impact of the anesthetic conserving device on occupational exposure to isoflurane among intensive care healthcare professionals - Minerva Anestesiologica 2018 January;84(1):25-32 - Minerva Medica - Journals

16 November 2018 in Der Anaesthesist
Verified
Journal Article
Closed access
PDF file
HVH. Vogelsang
H. Vogelsang
NBN. M. Botteck
N. M. Botteck
JHJ. Herzog-Niescery
J. Herzog-Niescery
JKJ. Kirov
J. Kirov
DLD. Litschko
D. Litschko
PGP. Gude
P. Gude

10 June 2020 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Open access
PDF file
HVHeike Vogelsang
Heike Vogelsang
ALAlexander Lang
Alexander Lang
BCBilal Cevik
Bilal Cevik
NBNikolaj M. Botteck
Nikolaj M. Botteck
TWThomas P. Weber
Thomas P. Weber
JHJennifer Herzog-Niescery
Jennifer Herzog-Niescery
Background: Thoracic epidural analgesia is beneficial after major abdominal surgery, though side‐effects and complications are rare but potentially devastating. The incidence of catheter‐related infection is approximately 5.5%. Several guidelines have been recommended to prevent complications during thoracic epidural catheterization. Tunnelling is often recommended to reduce the incidence of infections and dislocations.Methods: A retrospective, single‐centre analysis of our acute pain service database was performed between 2010 and 2018. The hygiene measures of the German Society of Anaesthesiology have been incorporated in our standard operating protocol since 2009. The procedure remained constant, but the skin disinfectant was changed from propan‐2‐ol to propan‐2‐ol with octenidine in 2014. Tunnelling of catheters was not performed. We analysed the incidence of catheter‐related infections (primary endpoint) and effect of the used disinfectant (secondary endpoint).Results: A total of 2755 patients underwent elective major abdominal surgery with thoracic epidural catheterization. Sixteen patients (0.6%) showed symptoms of mild catheter‐related infection. Moderate or severe infections were not observed in any patient. The type of disinfectant did not show any significant effect on the incidence of infection.Conclusion: The incidence of catheter‐related infections was low, and only mild signs of infection were observed. Non‐tunnelling could be an alternative to tunnelling, especially if hygiene protocols are followed, and the duration of catheter use is short. A comprehensive database and regular examinations by trained staff are essential for early detection of abnormalities and immediate removal of the catheter, if required.

9 August 2019 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
JHJennifer Herzog-Niescery
Jennifer Herzog-Niescery
TSThomas Steffens
Thomas Steffens
MBMartin Bellgardt
Martin Bellgardt
ABAndreas Breuer-Kaiser
Andreas Breuer-Kaiser
PGPhilipp Gude
Philipp Gude
HSHans-Martin Seipp
Hans-Martin Seipp
Real-time photoacoustic gas monitoring is used for personnel exposure and environmental monitoring, but its accuracy varies when organic solvents such as alcohol contaminate measurements. This is problematic for anesthetic gas measurements in hospitals, because most disinfectants contain alcohol, which could lead to false-high gas concentrations. We investigated the cross-sensitivities of the photoacoustic gas monitor Innova 1412 (AirTech Instruments, LumaSense, Denmark) against alcohols and alcoholic disinfectants while measuring sevoflurane, desflurane and isoflurane in a laboratory and in hospital during surgery. 25 mL ethyl alcohol was distributed on a hotplate. An optical filter for isoflurane was used and the gas monitor measured the ‘isoflurane’ concentration for five minutes with the measuring probe fixed 30 cm above the hotplate. Then, 5 mL isoflurane was added vaporized via an Anesthetic Conserving Device (Sedana Medical, Uppsala, Sweden). After one-hour measurement, 25 mL isopropyl alcohol, N-propanol, and two alcoholic disinfectants were subsequently added, each in combination with 5 mL isoflurane. The same experiment was in turn performed for sevoflurane and desflurane. The practical impact of the cross-sensitivity was investigated on abdominal surgeons who were exposed intraoperatively to sevoflurane. A new approach to overcome the gas monitor’s cross-sensitivity is presented. Cross-sensitivity was observed for all alcohols and its strength characteristic for the tested agent. Simultaneous uses of anesthetic gases and alcohols increased the concentrations and the recovery times significantly, especially while sevoflurane was utilized. Intraoperative measurements revealed mean and maximum sevoflurane concentrations of 0.61 ± 0.26 ppm and 15.27 ± 14.62 ppm. We replaced the cross-sensitivity peaks with the 10th percentile baseline of the anesthetic gas concentration. This reduced mean and maximum concentrations significantly by 37% (p < 0.001) and 86% (p < 0.001), respectively. Photoacoustic gas monitoring is useful to detect lowest anesthetic gases concentrations, but cross-sensitivity caused one third falsely high measured mean gas concentration. One possibility to eliminate these peaks is the recovery time-based baseline approach. Caution should be taken while measuring sevoflurane, since marked cross-sensitivity peaks are to be expected.

26 July 2021 in Acta Anaesthesiologica Scandinavica
Verified
Journal Article
Open access
PDF file
PGPhilipp Gude
Philipp Gude
NGNiclas Geldermann
Niclas Geldermann
AGAdrian I. Georgevici
Adrian I. Georgevici
JHJennifer Herzog‐Niescery
Jennifer Herzog‐Niescery
TWThomas Peter Weber
Thomas Peter Weber
SVStefan Volkenstein
Stefan Volkenstein
Background: The optimal pain therapy for children undergoing tonsillotomy remains unknown. Our aim was to evaluate a standard pain therapy including the alternating application of ibuprofen and paracetamol.Methods: Pain intensity of 81 in‐patients after tonsillotomy aged 2–12 years was evaluated three times daily (mean observation 3.85 days) using the Children's and Infants’ Postoperative Pain Scale (CHIPPS) in children <5 years, or with the Faces Pain Scale‐Revised (FPS‐R) in older children. Parents completed the Parents’ Postoperative Pain Measure (PPPM‐D) in addition. Exceeding the cut‐off value in one of the scores implied the indication for an opioid rescue medication (RM). Endpoints were number of children with indication for the RM, course of pain, concordance between pain scales, and adverse events.Results: Overall, 45.7% of children needed the RM either in the recovery room or on the ward. The rate of children having an indication for RM on the ward was 30.9%. The highest proportion of affected children was identified on the day of surgery (32.1%). Most indications were detected with the PPPM‐D only. A comparison with an earlier study showed less affected children compared to ibuprofen monotherapy on the day of surgery and the first postoperative day. Eleven children (13.6%) developed fever.Conclusion: Although our pain therapy concept was effective from postoperative day 1 onwards, it needs improvement for the day of surgery. The overall concordance between the PPPM‐D and CHIPPS or FPS‐R was low. Fever might be a confounder for the pain intensity measurement with the PPPM‐D.

13 March 2020 in European Journal of Anaesthesiology
Verified
Journal Article
Closed access
HVHeike Vogelsang
Heike Vogelsang
JHJennifer Herzog-Niescery
Jennifer Herzog-Niescery
NBNikolaj M. Botteck
Nikolaj M. Botteck
FHFabian Hasse
Fabian Hasse
APAdam Peszko
Adam Peszko
PGPhilipp Gude
Philipp Gude
BACKGROUND Pre-operative risk assessment is important to quantify the patient's risks of morbidity and mortality, but its quality differs. We created a process-oriented score (PRO-score) for risk evaluation of adults as a three-stage warning score checklist with concrete guidance. It contains the contents of current guidelines and the assessment of vital signs. OBJECTIVES We investigated whether the PRO-score is suitable to detect ‘red flag’ warning signs not only in American Society of Anesthesiologists (ASA) physical status (PS) 3 or 4 patients but also in ASA-PS 1 or 2 patients. Resulting medical, therapeutic or structural consequences were recorded. DESIGN Prospective single-centre study. SETTING The study was performed in a German university hospital between November 2015 and December 2018. PATIENTS We included 54 455 adult patients undergoing a pre-operative risk assessment for general or regional anaesthesia and elective noncardiac surgery. RESULTS In all, 388 patients presented ‘red flag’ warning signs in the PRO-score during risk assessment; 85 (21.9%) were labelled ASA-PS 1 or 2, 244 (62.9%) ASA-PS 3 and 59 (15.2%) ASA-PS 4. Additional examinations were performed in 179 patients and technical tests in 175 patients (ASA-PS 1 or 2: 53 and 63 patients, respectively). After re-evaluation of the peri-operative risk in an interdisciplinary conference, surgery was cancelled in 44 patients (ASA-PS 1 and 2, 17 patients) or performed under local anaesthesia in 15 patients (ASA-PS 1 and 2, 2 patients). A downgrading to PRO-score 2 was reached in 168 patients after therapeutic interventions (ASA-PS 1 and 2, 54 patients). Undergoing surgery despite ‘red flag’ events resulted in major complications in 34 patients, and 16 patients died (ASA-PS 1 or 2: 7 and 3 patients, respectively). CONCLUSION The PRO-score detected warning signs in ‘healthy’ ASA-PS 1 or 2 and in ASA-PS 3 or 4 patients. Furthermore, it influenced the management of these patients, and thus improved the process quality of risk assessment. The physical examination should include the assessment of vital signs.