Article: The impact of the anesthetic conserving device on occupational exposure to isoflurane among intensive care healthcare professionals - Minerva Anestesiologica 2018 January;84(1):25-32 - Minerva Medica - Journals
1 February 2021 in International Journal of Obstetric Anesthesia
Real-time photoacoustic gas monitoring is used for personnel exposure and environmental monitoring, but its accuracy varies when organic solvents such as alcohol contaminate measurements. This is problematic for anesthetic gas measurements in hospitals, because most disinfectants contain alcohol, which could lead to false-high gas concentrations. We investigated the cross-sensitivities of the photoacoustic gas monitor Innova 1412 (AirTech Instruments, LumaSense, Denmark) against alcohols and alcoholic disinfectants while measuring sevoflurane, desflurane and isoflurane in a laboratory and in hospital during surgery. 25 mL ethyl alcohol was distributed on a hotplate. An optical filter for isoflurane was used and the gas monitor measured the ‘isoflurane’ concentration for five minutes with the measuring probe fixed 30 cm above the hotplate. Then, 5 mL isoflurane was added vaporized via an Anesthetic Conserving Device (Sedana Medical, Uppsala, Sweden). After one-hour measurement, 25 mL isopropyl alcohol, N-propanol, and two alcoholic disinfectants were subsequently added, each in combination with 5 mL isoflurane. The same experiment was in turn performed for sevoflurane and desflurane. The practical impact of the cross-sensitivity was investigated on abdominal surgeons who were exposed intraoperatively to sevoflurane. A new approach to overcome the gas monitor’s cross-sensitivity is presented. Cross-sensitivity was observed for all alcohols and its strength characteristic for the tested agent. Simultaneous uses of anesthetic gases and alcohols increased the concentrations and the recovery times significantly, especially while sevoflurane was utilized. Intraoperative measurements revealed mean and maximum sevoflurane concentrations of 0.61 ± 0.26 ppm and 15.27 ± 14.62 ppm. We replaced the cross-sensitivity peaks with the 10th percentile baseline of the anesthetic gas concentration. This reduced mean and maximum concentrations significantly by 37% (p < 0.001) and 86% (p < 0.001), respectively. Photoacoustic gas monitoring is useful to detect lowest anesthetic gases concentrations, but cross-sensitivity caused one third falsely high measured mean gas concentration. One possibility to eliminate these peaks is the recovery time-based baseline approach. Caution should be taken while measuring sevoflurane, since marked cross-sensitivity peaks are to be expected.
26 July 2021 in Acta Anaesthesiologica Scandinavica
Background: The optimal pain therapy for children undergoing tonsillotomy remains unknown. Our aim was to evaluate a standard pain therapy including the alternating application of ibuprofen and paracetamol.Methods: Pain intensity of 81 in‐patients after tonsillotomy aged 2–12 years was evaluated three times daily (mean observation 3.85 days) using the Children's and Infants’ Postoperative Pain Scale (CHIPPS) in children <5 years, or with the Faces Pain Scale‐Revised (FPS‐R) in older children. Parents completed the Parents’ Postoperative Pain Measure (PPPM‐D) in addition. Exceeding the cut‐off value in one of the scores implied the indication for an opioid rescue medication (RM). Endpoints were number of children with indication for the RM, course of pain, concordance between pain scales, and adverse events.Results: Overall, 45.7% of children needed the RM either in the recovery room or on the ward. The rate of children having an indication for RM on the ward was 30.9%. The highest proportion of affected children was identified on the day of surgery (32.1%). Most indications were detected with the PPPM‐D only. A comparison with an earlier study showed less affected children compared to ibuprofen monotherapy on the day of surgery and the first postoperative day. Eleven children (13.6%) developed fever.Conclusion: Although our pain therapy concept was effective from postoperative day 1 onwards, it needs improvement for the day of surgery. The overall concordance between the PPPM‐D and CHIPPS or FPS‐R was low. Fever might be a confounder for the pain intensity measurement with the PPPM‐D.