Lishi Zhang

Lishi Zhang

Auto-generated profile, based on publicly available information

Lishi Zhang

State Key Laboratory of Electrical Insulation and Power Equipment, Shaanxi Key Laboratory of Smart Grid, School of Electrical Engineering, Xian Jiaotong University, Xian, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2022 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
LZLishi Zhang
Lishi Zhang
YLYibin Liu
Yibin Liu
DLDeliang Liang
Deliang Liang
PKPeng Kou
Peng Kou
YWYuheng Wang
Yuheng Wang
HLHua Liu
Hua Liu
This paper proposes a hybrid distribution transformer integrating photovoltaics (HDT-PV) with local and remote cooperative control in an active distribution network (ADN). HDT-PVs, regarded as promising devices with high reliability and easy engineering in ADNs, can not only realize the on-site maximum utilization of distributed solar energy but also solve the various power quality problems that follow. Moreover, the reactive power flow in the ADN can be optimized through remote cooperative control of multiple HDT-PVs. In this situation, the two objectives of voltage regulation and network power loss decrease are achieved in the ADN. If the power electronic device in the HDT-PV fails, the HDT-PV is able to work as a conventional distribution transformer by cutting off all power electronic devices and PV systems. Even when a small number of HDT-PVs malfunction, the system can still run stably. Finally, the simulation and experimental results demonstrate the effectiveness of the proposed scheme.

29 June 2022 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YLYibin Liu
Yibin Liu
LZLishi Zhang
Lishi Zhang
DLDeliang Liang
Deliang Liang
HJHao Jin
Hao Jin
SLShichao Li
Shichao Li
SFShuai Feng
Shuai Feng
Hybrid distribution transformer (HDT) is realized by augmenting the traditional low-frequency transformer with a fractionally rated converter. This article improves the HDT topology by assembling the LCL -type converters and presents the grid currents and load voltages quasi-proportional-resonant (PR) control strategies for this improved HDT. The PR control schemes are developed based on the established stationary frame dynamic models of HDT, and the effects of the controller parameters and LCL -filter parameters variation on the HDT's control performance and harmonic suppression ability are analyzed by the Bode diagrams and step responses. The key feature of this article is that, by using the resonant controller and LCL -type filters, the complex coordinate transformation can be avoided and the high-frequency harmonics can be well suppressed in the HDT application. The simulation and experiment results verify the effectiveness of the improved HDT and the proposed control strategies.

1 March 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LZLishi Zhang
Lishi Zhang
YLYibin Liu
Yibin Liu
YWYuheng Wang
Yuheng Wang
DLDeliang Liang
Deliang Liang
ZKZihan Kong
Zihan Kong
LTLutian Tang
Lutian Tang
The hybrid distribution transformer integrated photovoltaic system (HDT-PV) is a promising solution for realizing the local consumption of distributed solar energy and solving the problems of the following power quality in the active distribution network. Due to the integration of power electronic converters and photovoltaic systems with low-frequency transformers, the fault situations of the HDT-PVs are more complicated and frequent than those of conventional distribution transformers. The lack of protection strategies for the HDT-PV, a new type of power equipment, greatly reduces its reliability and limits its potential for practical applications. To address this issue, the paper proposes multi-layer protection strategies for the HDT-PVs to remove the faulty part under different possible failure conditions. For each protection strategy, the corresponding fault-tolerant control system of the HDT-PV is designed to ensure the normal operation of other functions under different fault conditions. Finally, simulation and experimental results are provided to verify the effectiveness of the proposed multi-layer fault-tolerant protection strategies for the HDT-PVs.

14 September 2023 in Journal of Energy Storage
Verified
Journal Article
Closed access
QWQidong Wen
Qidong Wen
LZLishi Zhang
Lishi Zhang
ZLZhe Liang
Zhe Liang
DLDeliang Liang
Deliang Liang
YLYang Liang
Yang Liang
SYShuzhou Yang
Shuzhou Yang

11 September 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YLYibin Liu
Yibin Liu
LZLishi Zhang
Lishi Zhang
HLHua Liu
Hua Liu
DLDeliang Liang
Deliang Liang
SLShichao Li
Shichao Li
LTLutian Tang
Lutian Tang
Hybrid distribution transformer (HDT) has powerful controllability for system currents and voltages. To reduce the number of discrete magnetics and make highly efficient use of ferromagnetic materials, a novel structure of HDT with magnetic integration (IMHDT) is proposed in this article. The key features of this IMHDT are inserting the leakage magnetic iron cores and sharing the common magnetic branches, by these, all the discrete magnetics of HDT are integrated. The 3-D finite element analysis(FEA) model, the equivalent electric-magnetic circuit model and the control strategies for this IMHDT are further established. Simulation and experiment results verify that the proposed IMHDT can not only save ferromagnetic materials but also inherit all the controllability of HDT.

31 May 2024 in International Journal of Electrical Power & Energy Systems
Verified
Journal Article
Open access
LZLishi Zhang
Lishi Zhang
ZKZihan Kong
Zihan Kong
YLYibin Liu
Yibin Liu
DLDeliang Liang
Deliang Liang
LFLibo Fan
Libo Fan
JHJiabin Huang
Jiabin Huang