Matthias Bornitz

Matthias Bornitz

Auto-generated profile, based on publicly available information

Matthias Bornitz

Ear Research Center Dresden, Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine and University Hospital Carl Gustav Carus, TUD Dresden University of Technology, Dresden, Germany

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 December 2012 in Journal of Biophotonics
Verified
Journal Article
Closed access
PDF file
ABAnke Burkhardt
Anke Burkhardt
LKLars Kirsten
Lars Kirsten
MBMatthias Bornitz
Matthias Bornitz
TZThomas Zahnert
Thomas Zahnert
EKEdmund Koch
Edmund Koch

4 December 2018 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
LKLars Kirsten
Lars Kirsten
MSMartin Schindler
Martin Schindler
JMJoseph Morgenstern
Joseph Morgenstern
MEMikael Timo Erkkilä
Mikael Timo Erkkilä
JGJonas Golde
Jonas Golde
EKEdmund Koch
Edmund Koch
The middle ear consists of the tympanic membrane and the ossicles, and ensures the transduction of sound from the auditory canal to the inner ear. Thus, diseases of the middle ear are often accompanied by hearing loss, especially in case of Eustachian tube dysfunction, acute or chronic otitis media, or otosclerosis. In the clinical routine, the diagnosis of pathological alterations in the middle ear is carried out using otoscopy or ear microscopy, audiometry, and tympanometry in order to assess morphological and functional changes of the middle ear.

1 April 2022 in Biomaterials Science
Verified
Journal Article
Open access
PDF file
LBLukas Benecke
Lukas Benecke
ZCZhaoyu Chen
Zhaoyu Chen
IZInes Zeidler-Rentzsch
Ines Zeidler-Rentzsch
MWMax von Witzleben
Max von Witzleben
MBMatthias Bornitz
Matthias Bornitz
DADilbar Aibibu
Dilbar Aibibu
Most commonly, autologous grafts are used in tympanic membrane (TM) reconstruction. However, apart from the limited availability and the increased surgical risk, they cannot replicate the full functionality of the human TM properly. Hence, biomimetic synthetic TM implants have been developed in our project to overcome these drawbacks. These innovative TM implants are made from synthetic biopolymer polycaprolactone (PCL) and silk fibroin (SF) by electrospinning technology. Static and dynamic experiments have shown that the mechanical and oscillatory behavior of the TM implants can be tuned by adjusting the solution concentration, the SF and PCL mixing ratio and the electrospinning parameters. In addition, candidates for TM implants could have comparable acousto-mechanical properties to human TMs. Finally, these candidates were further validated in in vitro experiments by performing TM reconstruction in human cadaver temporal bones. The reconstructed TM with SF–PCL blend membranes fully recovered the acoustic vibration when the perforation was smaller than 50%. Furthermore, the handling, medium adhesion and transparency of the developed TM implants were similar to those of human TMs.

9 September 2023 in Acta Biomaterialia
Verified
Journal Article
Open access
MWMax von Witzleben
Max von Witzleben
TSThomas Stoppe
Thomas Stoppe
AZAlina Zeinalova
Alina Zeinalova
ZCZhaoyu Chen
Zhaoyu Chen
TATilman Ahlfeld
Tilman Ahlfeld
Michael GelinskyMichael Gelinsky
Michael Gelinsky
The three additive manufacturing techniques fused deposition modeling, gel plotting and melt electrowriting were combined to develop a mimicry of the tympanic membrane (TM) to tackle large TM perforations caused by chronic otitis media. The mimicry of the collagen fiber orientation of the TM was accompanied by a study of multiple funnel-shaped mimics of the TM morphology, resulting in mechanical and acoustic properties similar to those of the eardrum. For the different 3D printing techniques used, the process parameters were optimized to allow reasonable microfiber arrangements within the melt electrowriting setup. Interestingly, the fiber pattern was less important for the acousto-mechanical properties than the overall morphology. Furthermore, the behavior of keratinocytes and fibroblasts is crucial for the repair of the TM, and an in vitro study showed a high biocompatibility of both primary cell types while mimicking the respective cell layers of the TM. A simulation of the in vivo ingrowth of both cell types resulted in a cell growth orientation similar to the original collagen fiber orientation of the TM. Overall, the combined approach showed all the necessary parameters to support the growth of a neo-epithelial layer with a similar structure and morphology to the original membrane. It therefore offers a suitable alternative to autologous materials for the treatment of chronic otitis media. STATEMENT OF SIGNIFICANCE: Millions of people worldwide suffer from chronic middle ear infections. Although the tympanic membrane (TM) can be reconstructed with autologous materials, the grafts used for this purpose require extensive manual preparation during surgery. This affects not only the hearing ability but also the stability of the reconstructed TM, especially in the case of full TM reconstruction. The synthetic alternative presented here mimicked not only the fibrous structure of the TM but also its morphology, resulting in similar acousto-mechanical properties. Furthermore, its high biocompatibility supported the migration of keratinocytes and fibroblasts to form a neo-epithelial layer. Overall, this completely new TM replacement was achieved by combining three different additive manufacturing processes.

1 January 2012 in Otology & Neurotology
Verified
Journal Article
Closed access
IAIrina Arechvo
Irina Arechvo
MBMatthias Bornitz
Matthias Bornitz
NLNikoloz Lasurashvili
Nikoloz Lasurashvili
TZThomas Zahnert
Thomas Zahnert
TBThomas Beleites
Thomas Beleites
New flexible total ossicular prostheses with an integrated microjoint can compensate for large static displacements in the reconstructed ossicular chain. When properly designed, they can mimic the function of the joints of the intact chain and ensure good vibration transfer in both straight and bent conditions. Prosthesis dislocations and extrusions are frequently observed after middle ear surgery. They are mainly related to the altered distance between the coupling points because of large static eardrum displacements. The new prostheses consist of 2 titanium shafts, which are incorporated into a silicone body. The sound transfer function and stapes footplate displacement at static loads were evaluated in human temporal bones after ossicular reconstruction using prostheses with 2 different silicones with different hardness values. The stiffness and bending characteristics of the prostheses were investigated with a quasi-static load. The sound transfer properties of the middle ears with the prostheses inserted under uncompressed conditions were comparable with those of ears with intact ossicular chains. The implant with the soft silicone had improved acoustic transfer characteristics over the implant with the hard silicone in a compressed state. In the quasi-static experiments, the minimum medial footplate displacement was found with the same implant. The bending characteristics depended on the silicone stiffness and correlated closely with the point and angle of the load incidence. The titanium prostheses with a resilient joint that were investigated in this study had good sound transfer characteristics under optimal conditions as well as in a compressed state. As a result of joint bending, the implants compensate for the small changes in length of the ossicular chain that occur under varying middle ear pressure. The implants require a stable support at the stapes footplate to function properly.

29 March 2023 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
SSSvea Steuer
Svea Steuer
JMJoseph Morgenstern
Joseph Morgenstern
LKLars Kirsten
Lars Kirsten
MBMatthias Bornitz
Matthias Bornitz
MNMarcus Neudert
Marcus Neudert
JGJonas Golde
Jonas Golde
Optical coherence tomography (OCT) is an interferometric imaging technique based on near-infrared light that enables real-time volumetric tissue imaging with microscopic resolution and penetration depths of up to 2 mm. While OCT has been successfully commercialized in ophthalmology for diagnostics of the eye, the application of both morphologic and functional OCT imaging for hearing diagnostics has attracted significant interest in recent years.1 This includes not only the tympanic membrane (TM)2,3 but also the ossicular chain in the middle ear4 – 6 and the inner ear.7,8