Ranging from circuit-level characterization to designing a platform architecture, developing a design automation tool, and fabricating an system-on-chip (SoC), this paper deals with the entire development process for ultra-low power (ULP) SoCs for Internet of Things endnodes. More precisely, this paper first focuses on the unique characteristics of the ULP circuits, the temperature effect inversion (TEI), i.e., the delay of the ULP circuits decreases with increasing temperature. Existing TEI-aware low power (TEI-LP) techniques have incredible potential to further reduce power consumption of conventional ULP SoCs, but there is a critical limitation to be widely adopted in real SoCs. To address this limitation and realize the ULP SoCs that can fully benefit from the TEI-LP techniques, this paper proposes a new TEI-inspired SoC platform (TIP) architecture. On top of that, taking into account that the highly complex, time-consuming and labor-intensive development process of these ULP SoCs may hinder their widespread use for IoT endnodes, this paper presents a new EDA tool to accelerate ULP SoC development, RISC-V eXpress (RVX). Finally, By using the RVX, this paper introduces a TIP prototyping chip fabricated in 28nm FD-SOI technology. This chip demonstrates that power savings of up to 35% can be achieved by lowering the supply voltage from 0.54V to 0.48V at 25 and 0.44V at 80 while continuing to operate at a target 50MHz clock frequency.
A technology for low-power high data-rate digital capsule endoscopy with human body communication (CEHBC) is presented in this paper. To transfer the image data stably with low power consumption, the proposed system uses three major schemes: Frequency selective digital transmission (FSDT) modulation with HBC, the use of an algorithm to select electrode pairs, and the LineSync algorithm. The FSDT modulation supports high-data rate transmission and prevents the signal attenuation effect. The selection algorithm of the electrode pair finds the best receiving channel. The LineSync algorithm synchronizes the data and compensates for data polarity during the long data transmission section between the capsule endoscope and the receiver. Because all the major functional blocks of the CEHBC transmitter can be implemented as digital logics, they can be easily fabricated using the field programmable gate array (FPGA). Moreover, this CEHBC transmitter can achieve low power-consumption and can support a relatively high data rate in spite of using its clock a few tens of MHz slower. The proposed CEHBC-TXD is the digital portion of the CEHBC transmitter that provides low-power (3.7 mW) and high data-rate (6 Mbps) performance while it supports a high-resolution image (480 × 480 byte) at 3.13 fps.
31 January 2020 in IEEE Transactions on Instrumentation and Measurement
Human body communications (HBC) has recently emerged as an innovative alternative to the current radio frequency communications for realizing wireless body area networks (WBAN) using the human body as a transmission channel without wired or wireless connections. This study addresses the provision of reliable modeling of the human body as a passage of the electric signal delivery based on the impulse response measurement through the proposal of a measurement setup and signal processing techniques applicable to wearable devices for healthcare and bio-signal acquisition. In the experiments, customized impulse signals were applied to the body using battery-powered devices isolated to the earth-ground for the operating environments of wearable devices. The impulse responses passed through the body were measured considering 52 measurement conditions determined by the device locations from the head to ankle, and the body postures. Body channel transfer functions (BCTFs) for the respective conditions were derived by an adaptive filter approach using an iterative algorithm to minimize the mean squared error between the measured and modeled impulse responses. The channel analysis parameters, such as mean path-loss, root-mean-square delay spread, and mean and maximum excess delays were analyzed based on the measured body impulse responses. In addition, the practical bit-error-rate performance for HBC based on the BCTFs reproducing inter-symbol interference effects caused by the delay spreads of the body channels were explored to verify communication reliability in terms of the transmitter structures adopting digital transmission, sorts of human body channels, data rates, and operating frequencies.
1 July 2022 in IEEE Transactions on Instrumentation and Measurement
Spiking neural networks (SNNs) are inspired by biological behavior in the neural system processing information by the rate or delay components of discrete spiking signals in a massively parallel manner. Sparse and asynchronous spikes allow event-driven information processes, leading to low power consumption and fast inference. By exploiting these advantageous features of the SNNs, this article presents a signal detection method for human body communication (HBC), which has recently emerged as an innovative alternative for wireless body area networks using the human body as a signal transmission medium. In particular, binary spike signaling in the SNNs is highly appropriate for application in the digital signal transmission-based HBC systems. The experiments of body channel response (BCR) measurements using digital training signals show that the body channel characteristics vary with changes in body posture and device location, especially in wearable environments requiring small-sized devices powered by batteries. The proposed SNN structures can enhance communication performance from signal distortions, stemming from the effects of the time-dispersive body channel and bandwidth-limited receive filter. The proposed SNN-based transmission symbol code (TSC) detector (STD) can improve about 3.53 dB carrier-to-noise ratio (CNR) at a bit error rate (BER) of 10 -6 for a data rate of 1.3125 Mbps, compared to that of a conventional maximum likelihood (ML) detector. In addition, the proposed SNN-based preamble detector (SPD) can secure an approximately 150 wider threshold range than that of a conventional correlator to achieve a detection probability higher than 99.9% of the frame existence at a CNR of approximately 0 dB required for achieving a BER of 10 -6 by the STD.
20 May 2021 in IEEE Transactions on Instrumentation and Measurement
Human body communications (HBCs), employing the human body as a signal transmission medium, can provide efficient and intuitive methods to form a network in the body. This article presents a comprehensive study for a highly reliable HBC system, including body channel modeling, transceiver design, and performance evaluation through implementation, in consideration of practical sensor network environments for wearable and implantable devices applicable to healthcare and biosignal acquisition. Body channel characteristics based on capacitive couplings, such as root mean square delay spread and mean path gain (MPG), were explored by measuring the body impulse responses under 12 experimental conditions, determined by the variation in body postures and device locations between the wrist and positions assumed under the scalp through a customized experimental setup with micropig-derived biomembranes (MBMs) used for wrapping the devices to emulate an implantable environment. The proposed transceiver design for digital transmission, including a preamble structure and signal modulation method supporting a maximum data rate of 1 Mb/s, was verified through the performance evaluations conducted for examining the frame detection probability and bit error rate (BER) in the body channel model at multiple operating frequencies of 32, 42, and 64 MHz. The proposed system reliability was demonstrated by the achievement of a BER of below ${4.7\,\times \, }{10}^{-8}$ through battery-powered implemented devices with dimensions of ${30\times 30 }\,\,{\text {mm}}^{2}$ , comprising a digital signal processing module (DSPM) for signal generation and detection processes, and an analog front-end module (AFEM) for recovering the received signal from signal deterioration by severe path loss and time-dispersive effect in the body channel.