Aljoša Hafner

Aljoša Hafner

Auto-generated profile, based on publicly available information

Aljoša Hafner

Elettra Sincrotrone Trieste, Scientific and Quantum Computing Unit Trieste Italy

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 December 2024 in X-Ray Spectrometry
Verified
Journal Article
Open access
AHAljoša Hafner
Aljoša Hafner
LCLuca Costa
Luca Costa
GKGeorge Kourousias
George Kourousias
EDEdvard Dobovičnik
Edvard Dobovičnik
MCMarco Cautero
Marco Cautero
AGAlessandra Gianoncelli
Alessandra Gianoncelli
This manuscript details the advancements in developing a unique multimodal imaging setup, specifically the integration of X‐AFM on a synchrotron beamline that currently combines STXM and XRF. This triplet configuration operates within the soft x‐ray regime (< 2.5 keV) and necessitates high vacuum instrumentation, targeting sub‐micrometric applications with nanometric precision. Building on a previously successful prototype, the paper presents the current setup, the challenges encountered, and the solutions implemented. Additionally, it highlights significant custom developments in specialized electronics that enabled practical utilization of the new instrument. In particular, multiple samples, including asbestos fibers from a broader high‐impact research project, were measured and characterized in situ for the first time. The overall performance is critically evaluated through an ex‐situ comparison with a commercial single‐modality AFM system. Finally, the manuscript discusses the roadmap for future advancements in related instrumentation, methods, and applications.

23 November 2023 in The Analyst
Verified
Journal Article
Open access
PDF file
AHAljoša Hafner
Aljoša Hafner
LCLuca Costa
Luca Costa
GKGeorge Kourousias
George Kourousias
VBValentina Bonanni
Valentina Bonanni
MŽMilan Žižić
Milan Žižić
AGAlessandra Gianoncelli
Alessandra Gianoncelli
The development of an in situ combination of AFM and soft X-ray μXRF in a single instrument, with AFM integration accomplished without substantial original set-up alteration.

1 January 2026 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
AHAljoša Hafner
Aljoša Hafner
GKGeorge Kourousias
George Kourousias
MSMarco De Simone
Marco De Simone
RPRoberto Pugliese
Roberto Pugliese
In this paper, we introduce the Modular Adaptive Processing Infrastructure ( MAPI ), a comprehensive software suite and approach designed to streamline and enhance data analysis workflows in scientific research laboratories. MAPI selects and integrates multiple frameworks and toolkits into a web-based platform, offering a highly modular and adaptable solution for diverse data analysis requirements. By design, MAPI supports distributed processing across heterogeneous backends (edge workstations, on-premises servers, high-performance computing and public cloud), making it suitable for various beamlines and data-processing labs. This blueprint, or `recipe', provides a flexible infrastructure that can be tailored to specific experimental needs. We showcase MAPI 's application through its successful implementation on the X-ray computed tomography (CT) beamline, resulting in a system for tomographic processing ( STP3 ). The case study demonstrates MAPI 's effectiveness in meeting complex computational demands, highlighting its potential for widespread adoption in scientific research environments. Most of the results reported in the paper are from a production deployment on Elettra's SYRMEP beamline using two on-premises GPU servers, but two additional ongoing deployments on different beamlines are discussed.

1 May 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
AGAlessandra Gianoncelli
Alessandra Gianoncelli
VBValentina Bonanni
Valentina Bonanni
FGFrancesco Guzzi
Francesco Guzzi
AHA. Hafner
A. Hafner
ASA. Stolfa
A. Stolfa
GKGeorge Kourousias
George Kourousias
Here we present recent imaging developments implemented at the TwinMic soft X-ray microscopy beamline at Elettra Sincrotrone Trieste, highlighting multimodal instrumental capabilities through representative scientific applications. In particular, we describe the standard TwinMic scanning imaging mode, which enables the simultaneous acquisition of transmission signals via scanning transmission X-ray microscopy (STXM) and emission signals through low-energy X-ray Fluorescence (XRF). Both modalities can be combined with X-ray absorption near-edge structure (XANES) spectromicroscopy to provide complementary structural and chemical information. We further report the implementation of a newly developed in-vacuum X-AFM system, which enables concurrent topographic measurements during X-ray imaging. In addition, we highlight the beamline capability for coherent diffractive imaging approaches, including ptychography. Finally, we outline future perspectives for the beamline in the context of the ongoing Elettra 2.0 upgrade, which will transform the facility into a fourth-generation storage-ring X-ray source.

1 June 2026 in Journal of Instrumentation
Verified
Journal Article
Open access
GKGeorge Kourousias
George Kourousias
Sergio CarratoSergio Carrato
Sergio Carrato
FGFrancesco Guzzi
Francesco Guzzi
MBMatteo Billè
Matteo Billè
AHAljoša Hafner
Aljoša Hafner
Panagiotis DimitrakisPanagiotis Dimitrakis
Panagiotis Dimitrakis
Computed Tomography (CT) is fundamentally an inverse problem combining linear operators, regularization and discrete inference. Artificial intelligence has improved reconstruction, denoising and segmentation. Quantum Computing (QC) is typically discussed in terms of computational speed. For CT, the more relevant question is structural compatibility. Several CT subproblems admit formulations that are aligned with quantum-native primitives for structured linear algebra and quadratic optimization. This short paper identifies three directions: reconstruction, denoising and segmentation. It briefly formalizes each component and details a QUBO-based formulation for the segmentation stage implemented in a prototype demonstrator, QUBOSegment . We also report ongoing development of a production-oriented system, NextGenSegment (NGS) , built on our Modular Adaptive Processing Infrastructure (MAPI). This work is intentionally scoped as a formulation- and workflow-oriented proof of concept rather than a benchmarking study claiming quantum performance advantage. The aim is to expose the CT community to technically grounded QC formulations and to encourage systematic benchmarking in realistic synchrotron and laboratory settings.

8 November 2026 in X-Ray Spectrometry
Verified
Journal Article
Open access
GKGeorge Kourousias
George Kourousias
Sergio CarratoSergio Carrato
Sergio Carrato
FGFrancesco Guzzi
Francesco Guzzi
AGAlessandra Gianoncelli
Alessandra Gianoncelli
AHAljoša Hafner
Aljoša Hafner
Panagiotis DimitrakisPanagiotis Dimitrakis
Panagiotis Dimitrakis
X‐ray fluorescence (XRF) analysis combines spectral inverse modeling, elemental support selection and spatial interpretation. We develop quadratic unconstrained binary optimization (QUBO) and Ising formulations for these tasks. A detector‐response dictionary of broadened candidate emission‐line profiles induces a spectral overlap graph that determines the coupling topology: strongly overlapping lines produce strongly coupled binary variables, providing a diagnostic of ambiguity before optimization. We formulate elemental identification using exact binary selection with physical line‐consistency penalties, derive a fixed‐point non‐negative encoding for quantized deconvolution, and express elemental‐map segmentation and trace detection as spatially regularized binary energies extending established Markov‐random‐field and detection‐limit approaches. Synchrotron low‐energy XRF combines weak fluorescence, overlapping soft X‐ray lines and large hyperspectral datacubes. The formulations are exercised on a published soft X‐ray map of THP‐1‐derived macrophages exposed to erionite fibers, acquired at the TwinMic beamline of Elettra Sincrotrone Trieste, using its detector calibration, fitted peak areas and uncertainties. The browser‐based XRFQubo demonstrator implements overlap analysis, spatial trace detection and reduced 39‐variable support selection with classical simulated annealing. Fit‐derived tests identify practical requirements for per‐line amplitude scaling, amplitude‐block moves with classical warm starts, and statistical weighting. Selection frequency broadly follows fitted peak‐area significance, while spatial regularization consolidates contiguous trace detections and suppresses isolated labels. A separate four‐qubit experiment executes restricted conditional support‐selection objectives from two measured spectra on IBM and IQM processors. No quantum advantage is claimed. Extending our companion computed tomography study, this work provides quantum‐compatible formulations and a classical demonstrator for controlled benchmarking against established XRF methods.