Maryam Sarkarat

Maryam Sarkarat

Auto-generated profile, based on publicly available information

Maryam Sarkarat

Department of Engineering, Science and Mechanics, Pennsylvania State College of Engineering, University Park, PA, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2020 in Composites Part C: Open Access
Verified
Journal Article
Open access
MSMaryam Sarkarat
Maryam Sarkarat
MLMichael Lanagan
Michael Lanagan
DGDipankar Ghosh
Dipankar Ghosh
ALAndrew Lottes
Andrew Lottes
KBKent Budd
Kent Budd
RRRamakrishnan Rajagopalan
Ramakrishnan Rajagopalan

20 April 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
WCWei Chen
Wei Chen
BLByeong-Yeul Lee
Byeong-Yeul Lee
XZXiao-Hong Zhu
Xiao-Hong Zhu
HWHannes M. Wiesner
Hannes M. Wiesner
MSMaryam Sarkarat
Maryam Sarkarat
Michael LanaganMichael Lanagan
Michael Lanagan
This work introduces an innovative magnetic resonance (MR) imaging technology that incorporates radiofrequency (RF) coil(s) with permittivity-tunable ultrahigh dielectric constant (tuHDC) ceramics to significantly improve RF coil transmission and reception efficiencies, MR imaging sensitivity and signal-to-noise ratio (SNR). The tuHDC ceramics made of composite barium strontium titanate (BST) compounds (Ba 0.6 Sr 0.4 TiO 3 ) have low dielectric loss and very high permittivity tunability from 2,000 to 15000 by varying the ceramic temperature between 0°C and 40°C to achieve an optimal permittivity for MR imaging application. We demonstrated for the first time the proof of concept using the BST-based tuHDC-RF-coil technology to improve MR spectroscopic imaging performance of 17 O nuclide at 10.5 Tesla (T) at a low ceramic temperature and 23 Na nuclide at 7T at room temperature. We discovered a large and spatially independent noise reduction under an optimal ceramic temperature, which synergistically resulted in an unprecedented SNR improvement. Large improvements were also demonstrated for 1 H MRI on a 1.5T clinical scanner using the same ceramics. The tuHDC-RF-coil technology is robust, flexible and cost-effective; it presents a technical breakthrough to significantly improve imaging sensitivity and resolution for broad MR imaging applications; which is critical for advancing biomedical and neuroscience research, and improving diagnostic imaging.


1 August 2019 in MRS Advances
Verified
Journal Article
Closed access
PDF file
MSMaryam Sarkarat
Maryam Sarkarat
AMAmira B. Meddeb
Amira B. Meddeb
SKSridhar Komarneni
Sridhar Komarneni
ZOZoubeida Ounaies
Zoubeida Ounaies