Hannes M. Wiesner

Hannes M. Wiesner

Auto-generated profile, based on publicly available information

Hannes M. Wiesner

Center for Magnetic Resonance Research, Department of Radiology, University of Minnesota, Minneapolis, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2021 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
TWTao Wang
Tao Wang
XZXiao‐Hong Zhu
Xiao‐Hong Zhu
HLHuan Li
Huan Li
YZYi Zhang
Yi Zhang
WZWei Zhu
Wei Zhu
WCWei Chen
Wei Chen

21 September 2012 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
XZXiao-Hong Zhu
Xiao-Hong Zhu
YZYi Zhang
Yi Zhang
HWHannes M. Wiesner
Hannes M. Wiesner
KUKamil Ugurbil
Kamil Ugurbil
WCWei Chen
Wei Chen
The cerebral metabolic rate of oxygen of small animals can be reliably imaged using the in vivo 17O magnetic resonance approach at high field. However, a separate measurement is required for imaging the cerebral blood flow in the same animal. In this study, we demonstrate that the 17O NMR signal of metabolically produced H217O in the rat brain following an 17O2 inhalation can serve as a perfusion tracer and its decay rate can be used to determine the absolute values of cerebral blood flow across a wide range of animal conditions. This finding suggests that the in vivo 17O magnetic resonance approach is capable of imaging both cerebral metabolic rate of oxygen and cerebral blood flow simultaneously and noninvasively; and it provides new utilities for studying the cerebral oxygen metabolism and perfusion commonly associated with brain function and diseases. Magn Reson Med 70:309–314, 2013.

26 October 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
HWHannes M. Wiesner
Hannes M. Wiesner
DBDávid Z. Balla
Dávid Z. Balla
KSKlaus Scheffler
Klaus Scheffler
KUKâmil Uğurbil
Kâmil Uğurbil
XZXiao‐Hong Zhu
Xiao‐Hong Zhu
RPRolf Pohmann
Rolf Pohmann
Purpose: Oxygen‐17 (17O) MRS imaging, successfully used in the brain, is extended by imaging the oxygen metabolic rate in the resting skeletal muscle and used to determine the total whole‐body oxygen metabolic rate in the rat.Methods: During and after inhalations of 17O2 gas, dynamic 17O MRSI was performed in rats (n = 8) ventilated with N2O or N2 at 16.4 T. Time courses of the H217O concentration from regions of interest located in brain and muscle tissue were examined and used to fit an animal‐adapted 3‐phase metabolic model of oxygen consumption. CBF was determined with an independent washout method. Finally, body oxygen metabolic rate was calculated using a global steady‐state approach.Results: Cerebral metabolic rate of oxygen consumption was 1.97 ± 0.19 μmol/g/min on average. The resting metabolic rate of oxygen consumption in skeletal muscle was 0.32 ± 0.12 μmol/g/min and >6 times lower than cerebral metabolic rate of oxygen consumption. Global oxygen consumed by the body was 24.2 ± 3.6 mL O2/kg body weight/min. CBF was estimated to be 0.28 ± 0.02 mL/g/min and 0.34 ± 0.06 mL/g/min for the N2 and N2O ventilation condition, respectively.Conclusion: We have evaluated the feasibility of 17O MRSI for imaging and quantifying the oxygen consumption rate in low metabolizing organs such as the skeletal muscle at rest. Additionally, we have shown that CBF is slightly increased in the case of ventilation with N2O. We expect this study to be beneficial to the application of 17O MRSI to a wider range of organs, although further validation is advised.

20 April 2020 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
WCWei Chen
Wei Chen
BLByeong-Yeul Lee
Byeong-Yeul Lee
XZXiao-Hong Zhu
Xiao-Hong Zhu
HWHannes M. Wiesner
Hannes M. Wiesner
MSMaryam Sarkarat
Maryam Sarkarat
Michael LanaganMichael Lanagan
Michael Lanagan
This work introduces an innovative magnetic resonance (MR) imaging technology that incorporates radiofrequency (RF) coil(s) with permittivity-tunable ultrahigh dielectric constant (tuHDC) ceramics to significantly improve RF coil transmission and reception efficiencies, MR imaging sensitivity and signal-to-noise ratio (SNR). The tuHDC ceramics made of composite barium strontium titanate (BST) compounds (Ba 0.6 Sr 0.4 TiO 3 ) have low dielectric loss and very high permittivity tunability from 2,000 to 15000 by varying the ceramic temperature between 0°C and 40°C to achieve an optimal permittivity for MR imaging application. We demonstrated for the first time the proof of concept using the BST-based tuHDC-RF-coil technology to improve MR spectroscopic imaging performance of 17 O nuclide at 10.5 Tesla (T) at a low ceramic temperature and 23 Na nuclide at 7T at room temperature. We discovered a large and spatially independent noise reduction under an optimal ceramic temperature, which synergistically resulted in an unprecedented SNR improvement. Large improvements were also demonstrated for 1 H MRI on a 1.5T clinical scanner using the same ceramics. The tuHDC-RF-coil technology is robust, flexible and cost-effective; it presents a technical breakthrough to significantly improve imaging sensitivity and resolution for broad MR imaging applications; which is critical for advancing biomedical and neuroscience research, and improving diagnostic imaging.

22 June 2015 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
HWHannes M. Wiesner
Hannes M. Wiesner
DBDávid Z. Balla
Dávid Z. Balla
GSG. Shajan
G. Shajan
KSKlaus Scheffler
Klaus Scheffler
KUKâmil Uğurbil
Kâmil Uğurbil
RPRolf Pohmann
Rolf Pohmann

1 July 2014 in Journal of Pharmacological and Toxicological Methods
Verified
Journal Article
Closed access
DBDávid Z. Balla
Dávid Z. Balla
SSSaskia Schwarz
Saskia Schwarz
HWHannes M. Wiesner
Hannes M. Wiesner
AHAnita M. Hennige
Anita M. Hennige
RPRolf Pohmann
Rolf Pohmann