Dalia AlHarith

Dalia AlHarith

Auto-generated profile, based on publicly available information

Dalia AlHarith

Department of Restorative Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
RARaid Abdullah Almnea
Raid Abdullah Almnea
SASadun Mohammad Al Ageel Albeaji
Sadun Mohammad Al Ageel Albeaji
AAAhmed Ali Alelyani
Ahmed Ali Alelyani
DADalia Alharith
Dalia Alharith
AAAbdulmajeed Saeed Alshahrani
Abdulmajeed Saeed Alshahrani
MMmohammed moaleem
mohammed moaleem
Background: This simulated study of 30 severely curved L-shaped root canals aimed to compare preparation time, aberrations, width measurements, and fractured files of three nickel–titanium (Ni–Ti) files, namely, ProTaper, ProTaper Next (PTN), and WaveOne (WO). Methods: Thirty simulated L-curved root canals of resin blocks were randomly divided into three groups. The canals were prepared to a tip size of 25 using ProTaper, PTN, and WO rotary file systems. Pre- and post-operative views for each sample were captured by a professional camera at a standardized distance and position. Blue India ink was injected into the pre-operative canals, and red India ink was injected into the post-operative canals to give a clear superimposition image. Five points were assessed through the halfway of the canal to the orifice (area between the beginning of curvature and apical end point). Preparation time, aberrations, width measurements, and fractured files were recorded and analyzed. Results: Mean preparation time was longest in ProTaper (4.89± 0.68 minutes). PTN and WO were the fastest in preparing the canals (about 3 minutes). A statistically significant difference was found between WO and ProTaper & PTN and ProTaper (p=0.000), while the difference was non-significant (p > 0.05) between WO and PTN. Nine aberrations consisting of three zips, one ledge and one outer widening were related to ProTaper, while WO recorded a ledge and fractured file, but for PTN system, it verified an outer widening and ledge. Only one WO file fractured, with no deformation observed in the other instruments. No significance was recorded among the width measurements in the different levels. Conclusion: ProTaper next achieved faster cutting than the ProTaper and WO file systems. PTN maintained the best apical termination position and produced the least canal aberration, followed by WO and ProTaper.

1 September 2024 in Clinical, Cosmetic and Investigational Dentistry
Verified
Journal Article
Open access
PDF file
AAAbdulmajeed Saeed Alshahrani
Abdulmajeed Saeed Alshahrani
AAAhmed Ali Alelyani
Ahmed Ali Alelyani
SASadun Mohammad Al Ageel Albeaji
Sadun Mohammad Al Ageel Albeaji
DADalia Alharith
Dalia Alharith
AMAhmed Al Malwi
Ahmed Al Malwi
MMmohammed moaleem
mohammed moaleem
Aim: Root canal treatment (RCT) is a common procedure practiced daily by dentists worldwide. The current systematic review aimed to evaluate and compare clinical studies on the quality of root canal fillings (RCFs) carried out by dentists with different levels of experience conducted worldwide with those conducted specifically in Saudi Arabia (SA). Materials and Methods: A full literature search was conducted in Clarivate Analytics’ Web of Science, Elsevier’s Scopus, Embase, CINHAL, and PubMed, without a restriction to studies published before January 2015. Also, a manual search was carried out by checking papers that may have been missed during the electronic search. The following keywords were used: [(quality of root canal filling(s)) OR (quality of root canal obturation)) and dental practitioners as (general dental practitioners; final year students; endodontist; specialist) AND (root canal obturation) OR (endodontic treatment)]. Parameters of the quality of RCFs, such as length, density, and taper, were assessed and counted. Results: A total of 13 worldwide and nine SA studies were included in this review, published between 2015 and 2023. Molars were the most treated teeth, at 42.3% and 40.2% for the worldwide and SA studies, respectively. Cases treated by final year students had the highest percentage, at 60.0% for both study groups. The percentages of acceptable quality, with regard to the length, density, and taper of RCFs, were 70.9%, 77.6%, and 84.3%, and 73.2%, 64.6%, and 67.8% for the worldwide and SA studies, respectively. Conclusion: The overall acceptable quality of RCFs was marginally higher in worldwide studies than in SA studies. Both prevalences can be considered as good, which indicates that the quality of RCFs is moving in the right direction.

16 November 2026 in Physchem
Verified
Journal Article
Open access
PDF file
MAMohammad Alabdulkareem
Mohammad Alabdulkareem
WRWaseem W Radwan
Waseem W Radwan
AAAmmar AbuMostafa
Ammar AbuMostafa
DADalia Alharith
Dalia Alharith
BABasil Yousef Alamassi
Basil Yousef Alamassi
KAKhaled Aldalaan
Khaled Aldalaan
Background: The distance between the light-curing unit (LCU) tip and the resin composite surface is a clinically important factor that may influence the quality of polymerization. However, the magnitude and consistency of its effects across different composite materials and curing devices remain unclear. Objective: To systematically evaluate the effect of LCU tip-to-surface distance on the polymerization behavior of resin composites, including degree of conversion (DC), microhardness, depth of cure, and flexural strength. Methods: A systematic search of PubMed/MEDLINE, Scopus, Web of Science, Embase, and Google Scholar was conducted from database inception to August 2026. In vitro studies that investigated at least two curing distances and reported quantitative polymerization outcomes were included. Methodological quality was assessed using a modified reporting checklist for in vitro dental materials research (not a validated risk-of-bias instrument). Findings were synthesized narratively according to the SWiM framework, with exploratory random-effects meta-analyses performed where data permitted. Results: Sixteen in vitro studies met the inclusion criteria. The narrative synthesis indicated that there was a tendency towards an association of increasing curing distance with decreased degree of conversion (DC), hardness, flexural strength, and depth of cure. However, the size of the effect depended on material, light-curing unit, irradiance, and exposure time. In exploratory random effects meta-analyses, which were based on two to four studies, an increase in distance was associated with lower values in comparison to direct curing at 0 mm, with all estimates in the same direction: DC was lower by 12.26 percentage points (95% confidence interval [CI], 8.07–16.45; eight comparisons from four studies), hardness was lower (standard mean difference [SMD] = 1.18; 95% CI, 0.17–2.18; seven comparisons from three studies), Knoop hardness was lower (mean difference [MD] = −5.34; 95% CI, −8.69 to −1.98; two studies), flexural strength was lower by 12.18 MPa (95% CI, −21.86 to −2.50; three studies), and depth of cure was lower by 0.54 mm (95% CI, 0.36–0.73; two studies). Heterogeneity was considerable to very high (I2 = 71.7–99.7%); 95% prediction intervals for DC, hardness, flexural strength, and depth of cure included zero, and estimates for hardness and flexural strength were not statistically significant with the Hartung–Knapp adjustment. In a single study (not pooled), bulk-fill composites demonstrated higher DC than a conventional composite at 0 mm, whereas the conventional composite showed slightly higher DC than the bulk-fill composites at 4 mm. DC was higher at the top than the bottom surface at 0 mm in three out of three studies that reported both values. These pooled estimates should be considered exploratory. Considerable heterogeneity was identified across pooled analyses. Conclusions: In these in vitro studies, a greater distance between the LCU tip and the composite surface was generally associated with lower polymerization-related properties of resin composites, with differences most often reported from about 4 mm in the experimental settings tested; this is an experimental observation rather than a validated clinical threshold, and the maximum distance investigated was 9 mm. These exploratory findings are compatible with minimizing unnecessary curing distance, but their clinical relevance has not been established. Further research, including clinical studies, should determine whether compensation for curing distance and specific material/LCU combinations can overcome such differences.

1 January 2026 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
AAAmmar AbuMostafa
Ammar AbuMostafa
MAMohammed Almarshad
Mohammed Almarshad
DADalia Alharith
Dalia Alharith
MAMohammad Alabdulkareem
Mohammad Alabdulkareem
AAAlanoud Alqahtani
Alanoud Alqahtani
BABasil Yousef Alamassi
Basil Yousef Alamassi
Background: Root canal irrigation is essential for effective canal disinfection, but activation techniques may alter the mechanical properties of root dentin. Objective: To evaluate the effects of four different root canal irrigation techniques on root dentin nanohardness, elastic modulus, and flexural strength. Methods: Forty extracted human mandibular premolars with single straight canals were randomly allocated to four groups ( n = 10): traditional needle irrigation, passive ultrasonic irrigation (PUI), negative‐pressure irrigation, and XP‐Endo Finisher irrigation. During canal preparation, specimens were irrigated with 1% sodium hypochlorite. The final irrigation procedures were performed using 2.5% sodium hypochlorite and 17% EDTA with identical irrigant sequences and volumes across all groups. Root dentin nanohardness, elastic modulus, and flexural strength were evaluated. Data were analyzed using one‐way ANOVA and Tukey’s post hoc test ( p < 0.05). Results: Traditional needle irrigation demonstrated the highest nanohardness (0.489 ± 0.064 GPa), whereas ultrasonic irrigation showed the lowest values (0.391 ± 0.021 GPa). Negative‐pressure irrigation (0.466 ± 0.043 GPa) and XP‐Endo Finisher irrigation (0.436 ± 0.056 GPa) showed intermediate values. Elastic modulus did not differ significantly among the groups ( p = 0.148). Likewise, no significant difference in flexural strength was observed among the irrigation protocols ( p = 0.371). Conclusion: Under the conditions of this in vitro study, ultrasonic irrigation reduced dentin nanohardness, whereas neither elastic modulus nor flexural strength was significantly affected by the irrigation protocol.