The leakage inductance of high-frequency transformer affects the operating mode and performance in DC/DC converters, so it is necessary to calculate the leakage inductance accurately. In the existing analytical calculation methods of leakage inductance of high-frequency transformers with Litz wire winding, the non-area-equivalent high-frequency analytical method is applied to calculate leakage inductance. However, the calculated leakage inductance value is lower than its actual value due to the neglect of the irregular region between turns. In order to improve the calculation accuracy, this paper proposes an analytical calculation method of leakage inductance for high-frequency transformer with Litz wire winding, which considers irregular region between turns. The two-dimensional magnetic field distribution in transformer window and attenuation caused by high-frequency effects on magnetic field energy are analyzed and applied in this proposed method, to take the energy stored in irregular region between turns into account indirectly. Thus, the proposed analytical expression for leakage inductance is derived correspondingly. Finally, the accuracy of the proposed method is verified by simulations and experiments. The results indicate that the relative error of calculating leakage inductance can be reduce from 16.25% to 3.79% by the proposed method within a certain range of wire densities.
24 January 2025 in IEEE Transactions on Industrial Electronics
Inductive power transfer (IPT) has attracted a lot of attention, and it has a tendency toward high-power applications. However, the problem of nonuniform magnetic flux distribution exists and is unsolved in IPT systems, which will cause unbalanced core loss and local heat, lowering the system’s stability. Therefore, a novel terrace-shaped core made of nanocrystalline flake ribbon (NFR) is proposed and investigated to balance the magnetic flux in the core for curved double-D couplers. Unlike merely increasing the core thickness in the center area, the terrace-shaped NFR (T-NFR) can realize uniform magnetic flux distribution and balanced temperature along the core. The feasibility and effectiveness of the T-NFR core are verified on a 1 kW IPT system with a transmission efficiency of 92.13%. The experiment results show that the maximum temperature in the center area can be mitigated from 55 to 41.6 °C, exhibiting a 51.2% improvement in temperature discrepancy. Meanwhile, the weight of the proposed T-NFR core is only 47.2 g, obtaining a 62.27% reduction compared to the traditional bar-shaped core with uniform thickness.
29 March 2023 in IEEE Transactions on Power Electronics
This letter proposes a charging current ripple suppression strategy for battery energy storage T-type three-level converter. Under distorted grid voltage scenarios, the harmonic contents of grid voltage lead to current ripple during battery charging. Theoretical analysis and mathematical derivations of the charging current ripple are presented. Based on the analysis, a control scheme for suppressing the charging current ripple is proposed by simplified calculating to obtain the amplitude and phase of harmonic reference current, and adding a charging current suppression loop. The suppression performance is verified via a 100-kW three-phase three-wire T-type three-level converter with battery. The experimental results prove that the charging current ripple can be effectively eliminated with the proposed strategy.
3 January 2025 in IEEE Transactions on Power Electronics
Inductors are the essential components in electronic devices, but the nonuniform magnetic flux density distribution (MFDD) in toroidal cores will lead to premature saturation and reduced material utilization. To address this problem, we propose a nanocrystalline toroidal core with a permeability gradient (PG) along the radius direction. The permeability of the nanocrystalline flake ribbon (NFR) can be easily adjusted through a physical crushing process, providing the fabrication condition for the PG-NFR core. The influence of the sublayer number and the PG are simulated and investigated by finite-element analysis. In the experiment, four NFR cores are fabricated, and temperature rises are measured and compared. For a core with uniform permeability (μ = 1500), the inner temperature rises to 92.2 °C, while the outer side reaches 82.86 °C, resulting in a maximum difference of 9.34 °C. In contrast, the core with a PG (μ = 1600–2200) shows only a 2.51 °C discrepancy. Simulation and experimental results are in high agreement, indicating that the PG-NFR core achieves a more uniform MFDD.
24 March 2025 in IEEE Transactions on Power Electronics
Leakage inductance adjustment is vital for optimizing the performance of magnetically integrated dual-active-bridge (DAB) converters. This letter proposes a slidable structure to change the leakage inductance of the toroidal transformer, which will not introduce any extra windings or cores and is comparatively simple. By rotating the secondary winding slider in the transformer's core, the distance between the primary and secondary windings is changed, and thus the leakage inductance can be modified seamlessly. The leakage inductance varies sinusoidally with the rotation angle and linearly over a significant region. To verify the proposed transformer structure, a DAB prototype adopting the nanocrystalline flake ribbon core is built. The leakage inductance can be adjusted from 13.63 to 41.89 μH, corresponding to a 67.3% change. The suitable leakage inductance for the optimal performance of DAB is found to be between 15.29 to 26 μH for full load and 30.47 μH for half load, ensuring high efficiency and low current stress.
1 December 2025 in IEEE Transactions on Power Electronics
Dynamic wireless power transfer (DWPT) technology can achieve charging for devices on the move, like automated guided vehicles, which can dramatically improve their working efficiency. In this article, the generalized state-space averaging (GSSA) model of the DWPT system is established, where the state equations are derived in accordance with the equivalent circuit, and then all state variables are separated into sine and cosine items using the Fourier series. The established model reveals that the maximum efficiency points of the DWPT system are correlated with the phase differences between currents of two adjacent transmitting coils at different mutual inductance conditions. As a result, the system's efficiency can be optimized by adjusting the phase differences of transmitting currents. Finally, numerous simulations and experiments are conducted to verify the GSSA model. The results prove the high accuracy of the model, and the efficiency calculation errors are less than 0.21% and 2.38% when the phase differences are 0 and -89 degrees, respectively. The model exhibits only a one-degree error in tracking the maximum efficiency point when the receiver is located 5 cm away from the reference position. Additionally, the closed-loop experiments demonstrate that the efficiency optimization is achieved by tuning the Tx current's phase.