3 September 2020 in Journal of Applied Physics
Based on the experimental and theoretical signals of an open photoacoustic cell operating with modulation frequencies from 20 Hz to 20 kHz, a significant contribution of photogenerated excess carriers on the thermal and thermoelastic responses of an n-type silicon plate is observed for the very first time. This is achieved by comparing the measured amplitude and phase of the photoacoustic signal with their corresponding theoretical thermoelastic counterparts, for high enough modulation frequencies mainly. It is shown that the amplitude of the thermoelastic component of plasma-thin samples varies about two orders of magnitude with respect to the corresponding one of plasma-thick samples. Furthermore, we find a maximal temperature difference ΔT = − 35 nK between the illuminated and non-illuminated sample surfaces, which shows that thin silicon plates with excess carriers could be used as heat sinks.
1 January 2016 in Facta universitatis - series: Physics, Chemistry and Technology
The paper discusses the most common impacts of the measuring system on the amplitude and phase of the photoacoustic signals in the frequency domain using the open-cell experimental set-up. The highest signal distortions are detected at the ends of the observed modulation frequency range from 20 Hz to 20 kHz. The attenuation of the signal is observed at lower frequencies, caused by the electronic filtering of the microphone and sound card, with characteristic frequencies of 15 Hz and 25 Hz. At higher frequencies, the dominant signal distortions are caused by the microphone acoustic filtering, having characteristic frequencies around 9 kHz and 15 kHz. It has been found that the microphone incoherent noise, the so called flicker noise, is negligibly small in comparison to the signal and does not affect the signal shape. However, a coherent noise originating from the power modulation system of the light source significantly affects the shape of the signal in the range greater than 10 kHz. The effects of the coherent noise and measuring system influence are eliminated completely using the relevant signal correction procedure targeting the photoacoustic signal generated by the sample.
1 January 2018 in Facta universitatis - series: Electronics and Energetics
The temperature distributions in the n-type silicon circular plate, excited by a frequency-modulated light source from one side, are investigated theoretically in the frequency domain. The influence of the photogenerated excess carrier density on the temperature distributions is considered with respect to the sample thickness, surface quality and carrier lifetime. The presence of the thermalization and non-radiative recombination processes are taken into account. The existence of the fast and slow heat sources in the sample is recognized. It is shown that the temperature distribution on sample surfaces is a sensitive function of an excess carrier density under a bulk and surface recombination. The most favorable values of surface velocities ratio and bulk lifetime are established, assigned for a simpler and more effective analysis of the carrier influence in semiconductors. The photothermal and photoacoustic transmission detection configuration is proposed as a most suitable experimental scheme for the investigation of the excess carrier influence on the silicon surface temperatures.
23 February 2022 in Journal of Applied Physics
The reduction of the photogenerated charge carriers' influence in periodically illuminated thin silicon membranes is investigated by using the experimental setup of an open photoacoustic cell in the standard range of modulation frequencies from 20 Hz to 20 kHz. It is confirmed that the deposition of a 200 nm thin film of titanium dioxide on the 30- and 50 μm silicon membrane leads to a large increase of the thermoelastic component of the photoacoustic signal, which restores the flexibility lost to the membrane under the influence of photogenerated carriers. The effect of the thermoelastic component enhancement is analyzed by observing the displacement of the tested samples along the heat propagation axis, depending on the carrier density and temperature differences on the illuminated and unilluminated sides, for different membrane thicknesses and a constant film thickness. It is found that the effect of enhancement of several orders of magnitude is more visible in thinner membranes due to higher ratios between the film and membrane thicknesses.
4 May 2020 in International Journal of Thermophysics
9 February 2022 in Silicon